Yanfeng Sui

Yanfeng Sui


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2023 in Symmetry
Verified
Journal Article
Open access
PDF file
JHJun He
Jun He
YSYanfeng Sui
Yanfeng Sui
YLYong Li
Yong Li
HMHuizhou Ma
Huizhou Ma
YDYaoyao Du
Yaoyao Du
JCJianshe Cao
Jianshe Cao
Beam position monitor (BPM) characterization has been widely studied at the synchrotron. The characteristic impedance of a stripline BPM was designed using a simulation and measured using the time-domain reflectometer method. The mechanical and electrical parameters of the feedthroughs with the buttons used for the BPMs were measured. Special care was taken in the analysis of the consistency of the four channels of the BPM. The feedthroughs were sorted based on their capacitance values. This paper presents the characterization results of the feedthroughs and BPMs. The electro-mechanical offsets were measured using the Lambertson method, and the calibration coefficients were measured using a stretched wire. The BPM differences introduced during mass production were determined by a statistical analysis of the measurement results.

31 January 2022 in Radiation Detection Technology and Methods
Verified
Journal Article
Closed access
PDF file
JHJun He
Jun He
YSYanfeng Sui
Yanfeng Sui
YLYan-Hua Lu
Yan-Hua Lu
YDYao-Yao Du
Yao-Yao Du
LWLin Wang
Lin Wang
JCJian-She Cao
Jian-She Cao

8 August 2022 in Radiation Detection Technology and Methods
Verified
Journal Article
Closed access
PDF file
YLYong Li
Yong Li
JHJun He
Jun He
YSYanfeng Sui
Yanfeng Sui
AWAnxin Wang
Anxin Wang
LWLin Wang
Lin Wang
JCJianshe Cao
Jianshe Cao

16 June 2020 in Radiation Detection Technology and Methods
Verified
Journal Article
Open access
PDF file
QZQi Zhang
Qi Zhang
JCJianshe Cao
Jianshe Cao
YSYanfeng Sui
Yanfeng Sui
Background: BEPC II is an electron–positron collider with a beam energy of 1.89 GeV and luminosity of 1 × 1033 cm−2 s−1. Being a complex accelerator, fault diagnostics both in an accurate manner and in time are often challenging during its operation. Purpose: The fault diagnosis research platform is capable of locating and resolving faults on time, thus can largely improve the operation of BEPCII by reducing downtime due to machine fault and consequently satisfying the demand for fault diagnosis of a complex system. Methods: Making full use of the existing large-scale hardware foundation, abundant data resources and previous experiences, a fault diagnosis research platform was built by applying data mining, machine learning and other related algorithms to carry out specific fault analysis on the entire system. Conclusion: The fault diagnosis research platform has been developed with implemented functions of data query, statistics and analysis. Partial fault diagnoses of the three subsystems have been realized. The 4W1 power supply fault has been successfully discovered, and effective solutions have been subsequently provided.

1 October 2010 in Chinese Physics C
Verified
Journal Article
Closed access
YSYanfeng Sui
Yanfeng Sui
WLWang Lin
Wang Lin
ZYZhao Ying
Zhao Ying
YJYue Jun-Hui
Yue Jun-Hui
LXLi Xiao-Ping
Li Xiao-Ping
MLMa Li
Ma Li

6 May 2024 in Symmetry
Verified
Journal Article
Open access
PDF file
JHJun He
Jun He
YSYanfeng Sui
Yanfeng Sui
CLChongyang Liang
Chongyang Liang
YDYaoyao Du
Yaoyao Du
YZYing Zhao
Ying Zhao
JCJianshe Cao
Jianshe Cao
The beam position is the most important reference basis for the operation of synchrotron radiation light sources, particularly for commissioning the first-turn injection of fourth-generation light sources. To improve the accuracy of the beam position measurement, we analyzed methods for calculating the beam position, and a finite element calculation and the stretched wire calibration system were used to demonstrate the procedure. We proved the relationship between the coverage range, fitting order, scanning step size, and accuracy both theoretically and experimentally, which can provide a basis for selecting the appropriate fitting order for different operation stages of the accelerator. It was proved that the accuracy of beam position calculations using simplified polynomial coefficients is comparable to those without a simplified one, which can save resources for reading electronic processing. The testing results of a batch of beam position monitors (BPMs) were in good agreement with the finite element calculation results, and the small difference between the manufactured BPMs also proved that quality control was performed well, and it benefited from button sorting.