Mohsen Sharifi

Dr. Mohsen Sharifi


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2022 in Energy Conversion and Management
Verified
Journal Article
Closed access
MSMohsen Sharifi
Mohsen Sharifi
IFIago Cupeiro Figueroa
Iago Cupeiro Figueroa
RMRana Mahmoud
Rana Mahmoud
EHEline Himpe
Eline Himpe
LHLieve Helsen
Lieve Helsen
JLJelle Laverge
Jelle Laverge

2 February 2022 in Journal of Building Engineering
Verified
Journal Article
Closed access
MSMohsen Sharifi
Mohsen Sharifi
RMRana Mahmoud
Rana Mahmoud
EHEline Himpe
Eline Himpe
JLJelle Laverge
Jelle Laverge

25 May 2022 in Science and Technology for the Built Environment
Verified
Journal Article
Open access
RMRana Mahmoud
Rana Mahmoud
MSMohsen Sharifi
Mohsen Sharifi
EHEline Himpe
Eline Himpe
JLJelle Laverge
Jelle Laverge
Hybrid Ground Source Heat Pump (GSHP) coupled with radiant emission system is a storage-integrated renewable HVAC technology. Previous attempts that assessed the potential of such a system either employed steady-state estimates or were limited to a few cases. However, incorporating system and building dynamics is crucial to accurately estimate the GSHP's share in the total final energy delivered to the building, hence its energy performance. This paper assesses the environmental and energy performance of the system in non-residential building typologies in the EU. It provides a robust quantification of its potential in the building sector's clean energy transition. We developed an automated method employing dynamic models to estimate building thermal loads. Parametric archetypes were developed to represent the diverse characteristics of the EU non-residential building stock. The analysis of 94,000 cases showed that the storage-integrated hybrid GSHP system covers more than 50% of the annual energy demand in 55% of the cases. The system reduced annual median primary energy and CO2 emissions by half compared to conventional systems, reaching 25 kWh/(m2.a) and 5 kgCO2/(m2.a), respectively. These results suggest that a significant reduction in CO2 emissions is achievable by implementing storage-integrated hybrid GSHP in the EU non-residential buildings.

9 June 2025 in Sustainable Cities and Society
Verified
Journal Article
Open access
MSMohsen Sharifi
Mohsen Sharifi
AKAmin Kouti
Amin Kouti
Mohammad Haris ShamsiMohammad Haris Shamsi
Mohammad Haris Shamsi
RGRui Guo
Rui Guo
DSDirk Saelens
Dirk Saelens

18 October 2023 in Energies
Verified
Journal Article
Open access
PDF file
MSMohsen Sharifi
Mohsen Sharifi
AKAmin Kouti
Amin Kouti
ELEvi Lambie
Evi Lambie
YMYIXIAO MA
YIXIAO MA
MFMaría Fernández
María Fernández
Mohammad Haris ShamsiMohammad Haris Shamsi
Mohammad Haris Shamsi
The availability of building operational data such as energy use and indoor temperature provides opportunities to enhance the traditional building energy performance calculation. Disaggregated building energy use facilitates informed decision-making to identify cost-saving measures efficiently at the individual building and building stock levels. The existing energy performance analysis techniques with measured input data in the literature are fragmented. Moreover, they frequently approach this issue with varying degrees of complexity depending on the available input data, expertise, and time. The procedure of choosing an appropriate method is often cumbersome with limited indication of the usefulness of the outcomes. This study proposes a data-driven framework for end-use load disaggregation through techniques that exploit various kinds of building consumption data. The results demonstrate the use of different techniques for varied applications. Calibrated theoretical calculation, data-driven heat loss coefficient (HLC), and energy signature curve (ESC) are among the proposed methods in the framework that facilitate individual, and urban scale energy decomposition. It is observed that different methods yield unalike outcomes, while their performance is predictable. While the HLC methods are flexible but also highly sensitive to the input parameters, the ESC needs high-frequency time series but provides stable energy decomposition. The ESC is efficient for large-scale analysis and the HLC method for detailed case-specific applications. Calibrated theoretical energy decomposition has a simple workflow and can supplement the current energy performance assessment method, although it entails sufficient input data.

1 November 2023 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
MSMohsen Sharifi
Mohsen Sharifi
MSMohammad Haris Shamsi
Mohammad Haris Shamsi
YMYixiao Ma
Yixiao Ma
DLDirk Lauwaet
Dirk Lauwaet
Climate change has resulted in an increase of average outdoor temperature worldwide. With the rise of average outdoor temperature and unprecedented frequent heat waves, the demand for cooling systems in residential buildings has risen even in countries such as Belgium with moderate climates. However, there is a trade-off to consider when it comes to cooling. While active cooling methods can effectively maintain thermal comfort, they also come with excessive energy use in comparison to passive cooling techniques. However, passive cooling methods can lead to thermal discomfort and health issues during heat waves. To better understand this balancing act, this paper uses building energy simulation together with the measured current and accurately projected future climate data with high spatial resolution to investigate and quantify the potential for overheating in a selected residential representative building in the Flemish region of Belgium. Optimal solutions for renovation of the building are investigated including a variety of weather scenarios to account for climate change and to provide future-proof solutions. Results indicate that the renovation strategy is not affected by climate change for this case study. High insulation level with passive cooling strategy provided minimum energy use and acceptable summer overheating below 100 hours for this case study. Active cooling with medium and light renovation measures come with acceptable thermal comfort while also result in higher total energy use up to 53%.