Andrea Cardia

Dr. Andrea Cardia

Service of Neurosurgery, Neurocenter of the Southern Switzerland Regional Hospital of Lugano, EOC, Lugano, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in World Neurosurgery
Verified
Journal Article
Closed access
Luca RicciardiLuca Ricciardi
Luca Ricciardi
KCKaisorn L. Chaichana
Kaisorn L. Chaichana
ACAndrea Cardia
Andrea Cardia
VSVito Stifano
Vito Stifano
ZRZefferino Rossini
Zefferino Rossini
Carmelo Lucio SturialeCarmelo Lucio Sturiale
Carmelo Lucio Sturiale

1 December 2008 in Surgical Neurology
Verified
Journal Article
Closed access
JHJuha Hernesniemi
Juha Hernesniemi
RRRossana Romani
Rossana Romani
BABaki S. Albayrak
Baki S. Albayrak
HLHanna Lehto
Hanna Lehto
RDReza Dashti
Reza Dashti
MNMika Niemelä
Mika Niemelä

1 January 2007 in Journal of Neurosurgery
Verified
Journal Article
Closed access
Paolo PerriniPaolo Perrini
Paolo Perrini
ACAndrea Cardia
Andrea Cardia
KFKenneth Fraser
Kenneth Fraser
GLGiuseppe Lanzino
Giuseppe Lanzino
Object: The authors studied the microsurgical anatomy of the ophthalmic artery (OphA), paying particular attention to its possibly dangerous anastomoses with the middle meningeal artery (MMA). Methods: The microsurgical anatomy of the OphA and its anastomoses with the MMA were studied in 14 vessels from seven adult cadaveric heads. The origination order of the OphA branches varies in relation to whether the artery, along its intraorbital course, crosses above or below the optic nerve (ON). The central retinal artery is the first branch to course from the OphA when it crosses over the ON, and it is the second branch to course from the OphA when the artery crosses under the ON. Anastomoses between branches of the MMA and the OphA were present in the majority of the specimens examined. Conclusions: Detailed knowledge of the microanatomy of the OphA and recognition of anastomoses between the external carotid artery and the OphA are critically important in avoiding disastrous complications during endovascular procedures.

1 November 2011 in Spine
Verified
Journal Article
Closed access
FCFrancesco Costa
Francesco Costa
ACAndrea Cardia
Andrea Cardia
AOAlessandro Ortolina
Alessandro Ortolina
FGFabio Galbusera
Fabio Galbusera
AZAlberto Zerbi
Alberto Zerbi
MFMaurizio Fornari
Maurizio Fornari
A retrospective clinical and radiological study. To compare the safety and accuracy of pedicle screw insertion using two different computed tomography (CT) data set acquisitions (preoperative and intraoperative) for computer-guidance systems in a series of 100 consecutive patients. Misplacement and pedicle cortical violation occurs in over 20% of screw placements and can result in potential neurovascular complications. Many technological innovations have been described to help reduce this range of error, such as image-guided surgery using fluoroscopy or CT-based image guidance. However, these techniques are not without their drawbacks. The next technological evolution is the use of an intraoperative CT scan, which would allow us to solve some of the critical phases of spinal navigation, such as position-dependent changes, thus granting a higher accuracy of the navigation system. The authors have compared and discussed the results of a preoperative and intraoperative CT data set acquisition mode for spinal navigation. One hundred consecutive patients with a diagnosis of lumbar degenerative spondylolisthesis who underwent a surgical approach of lumbar pedicle screw fixation using a CT-based computer-guidance system were evaluated. The population was divided into two groups: in group I, a preoperative CT scan was used for the navigation system; whereas in group II, an intraoperative CT scan acquired during surgery was used. Epidemiological and surgical data of the patients in the two groups were then analyzed and compared. The Pearson χ2 test was used for comparisons between groups (significance level 0.05). The evaluation and classification of the screw positioning was performed on the basis of a control CT scan according to the classification proposed by Laine. Out of 504 screws, 471 were correctly inserted into the pedicles (93.5%): the accuracy of group I was of 91.8%, whereas in group II it was 95.2% (no statistical significance). The overall rate of perforation was 6.5% (33 screws): 21 in group I and 12 in group II. Twenty-eight screws had a perforation of the pedicle less than 2 mm (Grade I), three comprised from 2 to 4 (Grade II), and only two more than 4 mm and less than 6 mm (Grade III). Out of 33 misplaced screws only one was replaced (graded as III in group II). Surgical time was shorter for group II, with a statistically significant difference. This result is mainly because of the automatic recognition and merging of the intraoperative images with the surgical anatomy that avoided the phase of registration with a paired-point technique. The results of this study suggest that the CT-based computer-assisted surgical navigation systems are precise, granting an elevated accuracy in pedicle screw positioning.

1 November 2017 in World Neurosurgery
Verified
Journal Article
Closed access
ZRZefferino Rossini
Zefferino Rossini
ACAndrea Cardia
Andrea Cardia
DMDavide Milani
Davide Milani
GLGiovanni Battista Lasio
Giovanni Battista Lasio
MFMaurizio Fornari
Maurizio Fornari
VDVincenzo D'ANgelo
Vincenzo D'ANgelo

1 November 2016 in Journal of Neurosurgery: Spine
Verified
Journal Article
Closed access
FCFrancesco Costa
Francesco Costa
GTGiovanni Tosi
Giovanni Tosi
LALuca Attuati
Luca Attuati
ACAndrea Cardia
Andrea Cardia
AOAlessandro Ortolina
Alessandro Ortolina
MFMaurizio Fornari
Maurizio Fornari
OBJECTIVE: The O-arm system in spine surgery allows greater accuracy, lower rate of screw misplacement, and reduced surgical time. Some concerns have been postulated regarding the radiation doses to patients and surgeons. To the best of the authors' knowledge, most of the studies in the literature were performed with the use of phantoms. The authors present data regarding radiation exposure of the surgeon and operating room (OR) staff in a consecutive series of patients undergoing spine surgery. METHODS: Radiation exposure data were collected in a series of 107 patients who underwent spine surgery using the O-arm system. The doses received by the surgeon and the staff were collected using electronic dosimeters. RESULTS: All patients underwent 1–3 scans. The mean radiation dose to the patients was 5.15 mSv (range 1.48–7.64 mSv). The mean dose registered for the scan operator was 0.005 μSv (range 0.00–0.03 μSv) while the other members of the surgical team positioned outside the OR received 0 μSv. CONCLUSIONS: The O-arm system exposes patients to a higher radiation dose than standard fluoroscopy. However, considering the clear advantages of this system, this adjunctive dose can be considered acceptable. Moreover, the effective dose to the patient can be reduced using collimation or minimizing the parameters of the O-arm system used in this paper. The exposure to operators is essentially negligible when radioprotective garments and protocols are adopted as recommended by the International Commission on Radiological Protection.