Naresh Kumar Mani

Dr. Naresh Kumar Mani


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2022 in Food Chemistry
Verified
Journal Article
Open access
RRRohitraj Ray
Rohitraj Ray
APAnusha Prabhu
Anusha Prabhu
DPDinesh Prasad
Dinesh Prasad
VGVijay Kumar Garlapati
Vijay Kumar Garlapati
Tejraj M. AminabhaviTejraj M. Aminabhavi
Tejraj M. Aminabhavi
Jesus Simal-GandaraJesus Simal-Gandara
Jesus Simal-Gandara
Analytical sciences have witnessed emergent techniques for efficient clinical and industrial food adulterants detection. In this review, the contributions made by the paper-based devices are highlighted for efficient and rapid detection of food adulterants and additives, which is the need of the hour and how different categories of techniques have been developed in the past decade for upgrading the performance for point-of-care testing. A simple strategy with an arrangement for detecting specific adulterants followed by the addition of samples to obtain well-defined qualitative or quantitative signals for confirming the presence of target species. The paper-based microfluidics-based technology advances and prospects for food adulterant detection are discussed given the high-demand from the food sectors and serve as a valued technology for food researchers working in interdisciplinary technological frontiers.

2 July 2020 in Cellulose
Verified
Journal Article
Open access
PDF file
APAnusha Prabhu
Anusha Prabhu
MNM. S. Giri Nandagopal
M. S. Giri Nandagopal
PYPrakash Peralam Yegneswaran
Prakash Peralam Yegneswaran
HSHardik Ramesh Singhal
Hardik Ramesh Singhal
NMNaresh Kumar Mani
Naresh Kumar Mani
We present a high resolution, ultra-frugal printing of paper microfluidic devices using in-house paraffin formulation on a simple filter paper. The patterns printed using an office inkjet printer formed a selective hydrophobic barrier of 4 ± 1 µm thickness with a hydrophilic channel width of 275 µm. These printed patterns effectively confine common aqueous solutions and solvents, which was verified by solvent compatibility studies. SEM analysis reveals that the solvent confinement is due to pore blockage in the filter paper. The fabricated paper-based device was validated for qualitative assessment of Candida albicans (pathogenic fungi) by using a combination of L-proline β-naphthylamide as the substrate and cinnamaldehyde as an indicator. Our studies reveal that the pathogenic fungi can be detected within 10 min with the limit of detection (LOD) of 0.86 × 106 cfu/mL. Owing to its simplicity, this facile method shows high potential and can be scaled up for developing robust paper-based devices for biomarker detection in resource-limited settings. Graphic abstract

3 May 2021 in ACS Omega
Verified
Journal Article
Open access
APAnusha Prabhu
Anusha Prabhu
HSHardik Singhal
Hardik Singhal
MNM. S. Giri Nandagopal
M. S. Giri Nandagopal
RKReshma Kulal
Reshma Kulal
PYPrakash Peralam Yegneswaran
Prakash Peralam Yegneswaran
NMNaresh Kumar Mani
Naresh Kumar Mani
Reproducible and in situ microbial detection, particularly of microbes significant in urinary tract infections (UTIs) such as Candida albicans, provides a unique opportunity to bring equity in the healthcare outcomes of disenfranchised groups like women in low-resource settings. Here, we demonstrate a system to potentially detect vulvovaginal candidiasis by leveraging the properties of multifilament cotton threads in the form of microfluidic-thread-based analytical devices (μTADs) to develop a frugal microbial identification assay. A facile mercerization method using heptane wash to boost reagent absorption and penetration is also performed and is shown to be robust compared to other existing conventional mercerization methods. Furthermore, the twisted mercerized fibers are drop-cast with media consisting of l-proline β-naphthylamide, which undergoes hydrolysis by the enzyme l-proline aminopeptidase secreted by C. albicans, hence signaling the presence of the pathogen via simple color change with a limit of detection of 0.58 × 106 cfu/mL. The flexible and easily disposable thread-based detection device when integrated with menstrual hygiene products showed a detection time of 10 min using spiked vaginal discharge. The developed method boasts a long shelf life and high stability, making it a discreet detection device for testing, which provides new vistas for self-testing multiple diseases that are considered taboo in certain societies.

17 July 2020 in RSC Advances
Verified
Journal Article
Open access
PDF file
APAnusha Prabhu
Anusha Prabhu
GSGiri Nandagopal M. S.
Giri Nandagopal M. S.
PYPrakash Peralam Yegneswaran
Prakash Peralam Yegneswaran
VPVijendra Prabhu
Vijendra Prabhu
UVUjjwal Verma
Ujjwal Verma
NMNaresh Kumar Mani
Naresh Kumar Mani
This study employs a commercial multifilament cotton thread as a low-cost microbial identification assay integrated with smartphone-based imaging for high throughput and rapid detection of pathogens. The thread device with inter-twined fibers was drop-cast with test media and a pH indicator. The target pathogens scavenge the media components with different sugars and release acidic by-products, which in turn act as markers for pH-based color change. The developed thread-based proof-of-concept was demonstrated for the visual color detection (red to yellow) of Candida albicans (≈16 hours) and Escherichia coli (≈5 hours). Besides that, using a smart-phone to capture images of the thread-based colorimetric assay facilitates early detection of turning point of the pH-based color change and further reduces the detection time of pathogens viz. Candida albicans (≈10 hours) and Escherichia coli (≈1.5 hours). The reported thread and smartphone integrated image analysis works towards identifying the turning point of the colorimetric change rather than the end-point analysis. Using this approach, the interpretation time can be significantly reduced compared to the existing conventional microbial methods (≈24 hours). The thread-based colorimetric microbial assay represents a ready-to-use, low-cost and straightforward technology with applicability in resource-constrained environments, surpassing the need for frequent fresh media preparation, expensive instrumentation, complex fabrication techniques and expert intervention. The proposed method possesses high scalability and reproducibility, which can be further extended to bio(chemical) assays.

13 December 2023 in Journal of Analysis and Testing
Verified
Journal Article
Open access
PDF file
ANAdhan Narasimhan
Adhan Narasimhan
HJHarshil Jain
Harshil Jain
KMKowshika Muniandy
Kowshika Muniandy
RCRaja Chinnappan
Raja Chinnappan
NMNaresh Kumar Mani
Naresh Kumar Mani
In light of the evolving nature of various diseases, time becomes a crucial factor in diagnosis and identifying the underlying causes. A point-of-care device provides a rapid diagnosis of a disease without using complex and advanced instruments, which are costly and difficult to transport. A paper-based device is a relatively frugal solution wherein the paper is used as a substratum in which the reactions are carried out. These methods are non-invasive, and the sample collection is relatively easy. Saliva is one such body fluid in which various biomarkers are present for numerous diseases. Bioanalysis of saliva has attracted more attention recently due to its non-invasiveness and robustness. Exploiting the discovery of clinical biomarkers from salivary analysis has the potential to revolutionize the healthcare sector by providing crucial information to monitor the health status of individuals and disease progression which enables personalized treatment. This review provides the limitation of the traditional methods in clinical applications and highlights the significance of saliva as a non-invasive biological fluid that is a source of multiple biomarkers associated with various diseases. It also provides insights into the different paper-based colorimetric microfluidic devices developed against salivary biomarkers in the past decade. The major challenges in the point-of-care application and the future prospects have been discussed as well. Further, we also emphasize the importance of this approach in dental disease diagnosis which is least explored and holds potential applications.

19 October 2021 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
AHAmrutha Hasandka
Amrutha Hasandka
ASAnkita Ramchandran Singh
Ankita Ramchandran Singh
APAnusha Prabhu
Anusha Prabhu
HSHardik Ramesh Singhal
Hardik Ramesh Singhal
MNM. S. Giri Nandagopal
M. S. Giri Nandagopal
NMNaresh Kumar Mani
Naresh Kumar Mani
Urinary tract infections (UTIs) make up a significant proportion of the global burden of disease in vulnerable groups and tend to substantially impair the quality of life of those affected, making timely detection of UTIs a priority for public health. However, economic and societal barriers drastically reduce accessibility of traditional lab-based testing methods for critical patient groups in low-resource areas, negatively affecting their overall healthcare outcomes. As a result, cellulose-based materials such as paper and thread have garnered significant interest among researchers as substrates for so-called frugal analytical devices which leverage the material’s portability and adaptability for facile and reproducible diagnoses of UTIs. Although the field may be only in its infancy, strategies aimed at commercial penetration can appreciably increase access to more healthcare options for at-risk people. In this review, we catalogue recent advances in devices that use cellulose-based materials as the primary housing or medium for UTI detection and chart out trends in the field. We also explore different modalities employed for detection, with particular emphasis on their ability to be ported onto discreet casings such as sanitary products. Graphical abstract