Mouna Elakhdar

Dr. Mouna Elakhdar

Tunis El Manar University, Tunis, Tunisia
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Energy Conversion and Management
Verified
Journal Article
Closed access
MEMouna Elakhdar
Mouna Elakhdar
HLHanene Landoulsi
Hanene Landoulsi
Bourhan TashtoushBourhan Tashtoush
Bourhan Tashtoush
ENEzzedine Nehdi
Ezzedine Nehdi
LKLakdar Kairouani
Lakdar Kairouani

1 September 2009 in International Journal of Refrigeration
Verified
Journal Article
Closed access
LKLakdar Kairouani
Lakdar Kairouani
MEMouna Elakhdar
Mouna Elakhdar
ENE. Nehdi
E. Nehdi
NBN. Bouaziz
N. Bouaziz

1 November 2018 in Energy
Verified
Journal Article
Closed access
MEMouna Elakhdar
Mouna Elakhdar
Bourhan TashtoushBourhan Tashtoush
Bourhan Tashtoush
ENE. Nehdi
E. Nehdi
LKLakdar Kairouani
Lakdar Kairouani

1 February 2017 in International Journal of Refrigeration
Verified
Journal Article
Closed access
KMK. Megdouli
K. Megdouli
Bourhan TashtoushBourhan Tashtoush
Bourhan Tashtoush
ENE. Nahdi
E. Nahdi
MEMouna Elakhdar
Mouna Elakhdar
AMA. Mhimid
A. Mhimid
LKL. Kairouani
L. Kairouani

9 April 2008 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
ENE. Nehdi
E. Nehdi
LKLakdar Kairouani
Lakdar Kairouani
MEMouna Elakhdar
Mouna Elakhdar
In this paper, the performance of the solar-driven ejector air conditioning with several environment-friendly working fluids is studied. The effect of the fluid nature and operating conditions on the ejector performance is examined. This performance is calculated using an empirical correlation. Thermodynamic properties of functioning fluids are obtained with a package REFPROP7. It appears that the refrigerant R717 offers the highest coefficient of performance (COP). For generator temperature TB = 90°C, condenser temperature TC = 35°C and evaporator temperature TE = 15°C and with R717, the COP of ejector air-conditioning system is 0.408. Using a meteorological data for the city of Tunis, the system performance is computed for three collector types. The air-conditioning season and period were taken for six months from April to September. The daily period is between 8 and 17 h. For the solar air-conditioning application, the COP of the overall system varied from 0.21 to 0.28 and the exergy efficiency varied from 0.14 to 0.19 with the same working conditions and total solar radiation (351–875 Wm−2) in July. Copyright © 2008 John Wiley & Sons, Ltd.

1 October 2016 in International Journal of Refrigeration
Verified
Journal Article
Closed access
KMK. Megdouli
K. Megdouli
Bourhan TashtoushBourhan Tashtoush
Bourhan Tashtoush
ENE. Nahdi
E. Nahdi
MEMouna Elakhdar
Mouna Elakhdar
LKL. Kairouani
L. Kairouani
AMA. Mhimid
A. Mhimid