A mathematical model for the pre-cooling process was established to solve the problems of the long pre-cooling time and uncertain parameters of cryogenic propellant tanks. The pre-cooling parameters of a 300 m3 liquid hydrogen tank at several cooling rates were calculated and analyzed. The results show that the liquid hydrogen flow required to pre-cool the gas in the tank, tank wall, accessories, and interlayer thermal insulation materials increases first and then decreases and that the liquid hydrogen flow needed to offset the heat leakage gradually increases with the temperature reduction. When the average cooling rate rose from 0.1 K/min to 1 K/min, the pre-cooling time was shortened from 2730 min to 273 min, and the consumption of liquid hydrogen decreased from 2115 kg to 2091 kg. Among the various heat loads, the inner tank wall and accessories consumed the most significant proportion of liquid hydrogen, accounting for 87.84% to 88.61%. The cooling capacity was derived from the liquid hydrogen’s evaporation and the cryogenic hydrogen gas’s heating process, of which the liquid hydrogen accounted for 23.00%. Considering the principle of safe operation, it is recommended that stepped pre-cooling in two or three stages based on the maximum cooling rate is conducted.
Concentration distribution is essential for the emergency disposal of cryogenic fuel leakage. In the dispersion process of cryogenic gas, its concentration is greatly influenced by the atmospheric water vapor. The authors have presented an adiabatic mixing model to derive the concentration of the cryogenic gas, in which the value of water vapor density is obtained by referring to the NIST database continuously. However, it is difficult to achieve fast system response times for real-time monitoring systems when calling NIST. Thus, a simple algebraic model of water vapor density with high calculation efficiency is necessary. Based on the detection of temperature and the solution of water vapor partial pressure, a calculation model was developed. For a given initial ambient temperature and relative humidity, the dew point could be solved by Qian’s correlation. By temperature comparisons of the mixture cloud, dew point, and triple point, the water vapor partial pressure can be calculated by the Goff–Gratch formulation. Then, the water vapor density during the temperature declining process can be derived via EOS. The results show that the model has high estimation accuracy, and has a close mean deviationof 0.08%to the IAPWS 95 of 0.03%. The increase in the computation efficiency was confirmed as +67% under nine testing points. The model facilitates the engineering utilization of the adiabatic mixing model for cryogenic fuel leakage monitoring.
19 June 2023 in Thermal Science and Engineering Progress