Obesity is one of the risk factors for osteoarthritis. The end-stage treatment for osteoarthritis is total knee arthroplasty (TKA). However, it remains controversial whether a high body mass index (BMI) affects the initial stability of the femoral prosthesis after TKA. Finite element analysis (FEA) was used to investigate this question in this study. Four femur models that assembled with TKA femoral components were reconstructed and divided into high BMI group and normal BMI group. The three-dimensional femurs were modeled and assigned inhomogeneous materials based on computed tomography (CT) images. Then each FEA model was applied with gait and deep bend loading conditions to evaluate the maximum principal strain on the distal femur and the relative micromotion between the femur and prosthesis. The mean strain of the high BMI group increased by 32.7% (936.9 με versus 706.1 με) and 50.9% (2064.5 με versus 1368.2 με) under gait and deep bend loading conditions, respectively, compared to the normal BMI group. Meanwhile, the mean micromotion of the high BMI group increased by 41.6% (2.77 μm versus 1.96 μm) and 58.5% (62.1 μm versus 39.2 μm), respectively. Under gait condition, the maximum micromotion for high BMI group was 33.8 μm and would compromise the initial stability. Under deep bend condition, the maximum strain and micromotion exceeded -7300 με and 28 μm for both groups. High BMI caused higher strain on the bone and higher micromotion between the prosthesis and the femur. Gait activities could be risky for prosthesis stability in high BMI group while be safe in normal group. Deep bend activities were highly dangerous for both groups with high BMI and normal BMI and should be avoided.
Aims: This study aimed to investigate the optimal sagittal positioning of the uncemented femoral component in total knee arthroplasty to minimize the risk of aseptic loosening and periprosthetic fracture.Methods: Ten different sagittal placements of the femoral component, ranging from -5 mm (causing anterior notch) to +4 mm (causing anterior gap), were analyzed using finite element analysis. Both gait and squat loading conditions were simulated, and Von Mises stress and interface micromotion were evaluated to assess fracture and loosening risk.Results: During gait, varied sagittal positioning did not lead to excessive Von Mises stress or micromotion. However, under squat conditions, posterior positioning (-4 and -5 mm) resulted in stress exceeding 150 MPa at the femoral notch, indicating potential fracture risk. Conversely, +1 mm and 0 mm sagittal positions demonstrated minimal interface micromotion.Conclusion: Slightly anterior sagittal positioning (+1 mm) or neutral positioning (0 mm) effectively reduced stress concentration at the femoral notch and minimized interface micromotion. Thus, these positions are deemed suitable to decrease the risk of aseptic loosening and periprosthetic femoral fracture.
5 August 2024 in International Journal for Numerical Methods in Biomedical Engineering
Aims: Acetabular bone defects pose a common challenge in revision total hip arthroplasty (THA). Our team has applied screw-supported prostheses to the revision of severe acetabular defects and achieved good early clinical results. However, in one of our cases, loosening of the screw-cup connection occurred five months after surgery. Therefore, we investigated the mechanical characteristics and weak points of this prosthesis system through finite element analysis (FEA) and mechanical testing, and proposed improvement strategies. Methods: A screw-supported prosthesis used in clinical practice was modelled, and FEA was performed to obtain its displacement and von Mises stress distribution under gait loading. Emphasis was placed on the stresses at the screw-cup connection to analyze the failure mechanism. Mechanical compression tests were subsequently performed on the prosthesis, and the failure mode of the prosthesis verified the results of the FEA. Results: FEA identified the posterior iliac and pubic locking connections as weak points prone to fatigue failure. Mechanical tests confirmed that the locking connection failed under 2,500 to 3,000 N loads. The improved sleeve connection enhanced connection strength and reduced failure risk. Conclusion: The screw-supported prosthesis shows potential for severe acetabular defects, but the screw-cup connection remains a vulnerable site. Enhanced connection designs (e.g. sleeve connection) and bone grafting effectively mitigate failure risk. Cite this article: Bone Joint Res 2026;15(3):204–214.
Aims: For cases of Anderson Orthopaedic Research Institute (AORI) type III proximal tibial defects with intact medial collateral ligaments (MCLs), knee reconstruction is conventionally performed using semi-constrained prostheses with stemmed tibial components in conjunction with cones or sleeves. This study aimed to reconstruct AORI type III tibial defects using a 3D-printed extension-stem augment, followed by surface-type knee reconstruction to achieve long-term stability and promising clinical outcomes. Methods: A patient-specific porous extension-stem augment was designed based on the defect morphology. The microporous structure allowed direct contact for osseointegration, the proximal portion supported tibial baseplate, while the distal stem achieved intramedullary fixation. Finite element analysis (FEA) assessed the biomechanical stability of the augment. A retrospective analysis was conducted between July 2021 and September 2023 on patients who underwent reconstruction of AORI type III proximal tibial defects with extension-stem augment and surface-type total knee prosthesis. Results: FEA demonstrated favourable stress and strain distribution and micromotion at the prosthesis-bone interface, although localized high-strain regions were observed under higher-demand loading conditions. Four patients (0 male, 4 female) were included, with a minimum follow-up of 20.7 months (20.7 to 30) and a median age at surgery of 63.0 years (IQR 60.3 to 66.3). The mean Knee Society Score (KSS) improved significantly to 85 (82 to 87), and the mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score decreased by 18 (16 to 20). One patient developed periprosthetic joint infection on the femoral side at 20.7 months postoperatively and underwent revision surgery. Intraoperatively, the augment was securely integrated and could not be extracted. Radiological evaluation demonstrated satisfactory alignment and joint stability, with no evidence of prosthesis loosening or migration at the latest follow-up. Conclusion: The extension-stem augment achieved anatomical reconstruction of AORI type III proximal tibial defects and provided stable support for the surface-type prosthesis, ensuring reliable knee stability after reconstruction. This represents a feasible option for revision of AORI type III tibial defects. Cite this article: Bone Joint Res 2026;15(10):1263–1273.