A tower anchorage structure with an exposed steel anchor box is commonly used for cable‐stayed bridges. Many researchers have conducted studies on this structure by considering a single segment. However, in practical engineering, the stress of multisegmented tower anchorage structure is not completely similar to that of single segment, and the forces between segments affect each other. Hence, in this study, the mechanical behavior of a multisegment anchorage structure with an exposed steel anchor box was investigated via finite element analysis. Furthermore, the load transfer path and stress distribution characteristics of the structure were investigated. The results indicate that the horizontal component of the cable force is borne by the side plate of the steel anchor box, the diaphragm, and the side wall of the concrete tower column, while the vertical component is transmitted by the steel anchor box and concrete tower column. Under the action of this cable force, the horizontal component of the cable force borne by the middle segment increases, while the components at the two end segments decrease. The vertical force is greater on the lower tower segments. The stress levels on the side plate and on the diaphragm of the steel anchor box in the middle section are high. Under the cable force load, the frame formed by the end plate and side plate of the steel anchor box expands outward. The end plate is mainly under a tensile load, and the tensile stress level on the lower section exceeds that on the upper section. A high‐stress area for the concrete tower is observed in the steel‐concrete joint. The stud group of the anchorage structure is subjected to horizontal and vertical shear forces, and no “saddle‐shaped” distribution of the stud shear is found. An optimal arrangement method for the stud group was proposed to optimize its mechanical performance.
16 June 2025 in Journal of Failure Analysis and Prevention
In order to further investigate the grouped stud effect on the force properties of stud connectors, based on the premise that the correctness of the finite element simulation method, in this paper, a finite element model of grouped stud connectors was developed, and the grouped stud effect and its sensitivity factors were analyzed in order to validate the recommended formula for calculating the shear capacity of grouped stud connectors. Results show that the number of grouped stud rows and stud row spacing have a significant influence on the grouped stud effect, and the unevenness coefficient of grouped stud force is negatively correlated with the number of grouped stud rows as well as the grouped stud row spacing. Grouped stud connectors with commonly used concrete grades greater than C50 and height-to-diameter ratios of greater than 4 in steel–concrete composite structural bridges are insensitive to changes in the concrete strength grades and the length of the studs. The direction of force transmission for grouped stud changes with the change in loading angle and the unevenness coefficient of force for the grouped stud will therefore be reduced. By comparing the results of the 62 existing groups of grouped stud connectors push-out tests, the mean of the tested to calculated value ratio was found to be 1.12, the variance was 0.023, the dispersion was small, and it was shown that the recommended formula has a high degree of accuracy. The results of this paper can be used as a theoretical basis for the study of the shear stress performance of grouped stud connectors.
In order to further investigate the study of the effect of grouped stud effect on the force properties of stud connector, based on the premise that the correctness of the finite element simulation method in this paper, finite element modeling of grouped stud connectors was developed, the grouped stud effect and its sensitivity factors were analyzed, to validate the recommended formula for calculating the shear capacity of grouped stud connectors. Results show that the number of grouped stud rows and row spacing have a significant effect on the grouped stud effect, and the unevenness coefficient of grouped stud force Ⅰ is negatively correlated with the number of grouped stud rows as well as the grouped stud row spacing. For grouped stud connectors with commonly used concrete grades greater than C50 and height-to-diameter ratios greater than 4 in steel-concrete composite structural bridges, which is insensitive to changes in the concrete strength grades and the length of the studs. The direction of force transmission for the grouped stud changes with the change of loading angle, and the unevenness coefficient of force for the grouped stud will therefore be reduced. By comparing the results of the 62 existing groups of grouped stud connectors push-out tests, the mean value of the ratio of tested to calculated values is found to be 1.12, the variance is 0.023, the dispersion is small, it is shown that the recommended formula has a high degree of accuracy. The results of this paper can be used as a theoretical basis for the study of the shear stress performance of grouped stud connectors.
In order to improve the shear resistance and structural ductility of the perfobond rib (PBL) connector, a new PBL connector with steel–rubber tenon is proposed in this study, which aims to increase the shear load capacity of the connector while improving the ductility of the connector. First, models of new PBLs are established based on the validated finite element method, and their mechanical properties are compared with other shear connectors. The results show that the stiffness and shear load capacity of the proposed connector can be effectively improved when the steel ring is added, where the shear stiffness can be reduced, and the deformation capacity of the specimen can be improved when the rubber ring is added. When a steel ring with a thickness of 5 mm and a rubber ring with a thickness of 5 mm are involved, the shear load capacity of the connector with steel–rubber tenon is increased by 13.7%, and the shear stiffness is reduced by 37.3% compared to the conventional concrete tenon connector, while the ductility is increased by 75.1% compared to the connector with steel ring tenon. Subsequently, as for the connectors with steel–rubber tenon, the effects of the thickness of the steel ring, the thickness of the rubber ring, the diameter of perforated rebar, the strength of concrete and the strength of perforated steel plate are analyzed based on the finite element model of a PBL. The results show that an increase in the thickness of the steel ring, the diameter of the perforated rebar and the strength of the concrete will cause an increase in the shear stiffness and shear load capacity of the connector; however, an increase in the thickness of the rubber ring can cause a decrease in the shear stiffness and shear load capacity of the connector, while a change in the strength of perforated steel plate has little effect on the shear stiffness and shear load-carrying capacity. Finally, based on the finite element parametric analysis results and the damage mechanism of the proposed connector, a calculation equation applicable to the PBL connector with steel–rubber tenon is presented to predict the shear load capacity of the connector.
1 September 2026 in Journal of Structural Engineering
To tackle the challenges posed by the unsuitability of traditional perfobond leiste (PBL) connectors for prefabricated steel–concrete structures and the reduction in deformation capacity observed when utilized with high-strength cementitious materials, assembled perfobond leiste connectors with steel-rubber tenon (ASR-PBL connectors) is proposed. Based on the varying tenon configurations, three groups of nine specimens were designed for the push-out test. Additionally, an investigation into the load–slip curves, damage patterns, and the shear influencing parameters of ASR-PBL connectors was conducted utilizing finite element methods. The results reveal that the shear stiffness and shear capacity of assembled perfobond leiste connectors with steel ring tenon (AS-PBL connectors), exhibit an increase of 99.6% and 11.4%, compared to the assembled PBL connectors with concrete tenon (A-PBL connectors), and a 52.7% reduction in shear stiffness of ASR-PBL connectors compared to AS-PBL connectors are observed, concurrent with a significant increase in the deformation capacity of the connectors is shown. Last, utilizing multiple regression analysis and the elastic foundation beam theory, the formula for calculating the shear capacity and shear stiffness of ASR-PBL connectors were proposed, respectively. ASR-PBL connectors has excellent shear resistance and deformation capacity, promoting the PBL connectors in steel–concrete composite structure construction engineering.