The thermal radiation phenomenon is more crucial than other thermal transportation phenomena at elevated temperatures (>300 °C). Therefore, infrared radiation resistance and its performance on thermal conduction of nanofibrous aerogel with Titanium oxide (TiO2) filler have been investigated compared to control groups (silica nanofibrous aerogels with and without filler). Nanofibrous aerogel has been produced by electrospun silica nanofibers. Later, TiO2 opacifier and a non-opacifier filled materials were prepared by a solution homogenization method and then freeze-dried to obtain particle-filled nanofibrous aerogel. Moreover, the thermal radiation conductivity of the composite was calculated by numerical simulation, and the effect of the anti-infrared radiation of the TiO2 opacifier was obtained. The fascinating inhibited infrared radiation transmission performance (infrared transmittance ~67% at 3 μm) and excellent thermal insulation effect (thermal conductivity of 0.019 Wm−1K−1 at room temperature) and maximum compressive strengths (3.22 kPa) of silica nanofibrous aerogel with TiO2 opacifier were verified. Excellent thermal insulation, compression and thermal stability properties show its potential for practical application in industrial production. The successful synthesis of this material may shed light on the development of other insulative ceramic aerogels.
Ensuring human health safety necessitates rigorous biosafety evaluations of substances and materials, particularly in the context of in-vivo exposure. Biodegradable materials, known for their natural decomposition capabilities through biological mechanisms, may exhibit toxicological profiles differing from non-biodegradable substances. Prior to their application in medical devices such as stents and implants, it is imperative to conduct thorough testing to ascertain their safety. This chapter aims to provide a comprehensive assessment of the in-vivo biosafety of various biodegradable materials. The authors employ an integrative approach, combining in-vitro ion-tolerance assays with in-vivo microanalysis techniques. This dual methodology allows for a detailed evaluation of the materials' biocompatibility and potential toxicity, particularly focusing on nanomaterial-induced toxicity in neural tissues. These findings offer critical insights into the safe application of biodegradable biomedical materials, underpinning informed decision-making in their usage for medical applications.
23 September 2022 in Journal of Materials Science: Materials in Medicine
Chitosan coatings have shown good bioactive properties such as antibacterial and antiplatelet properties, especially on blood-contacted biomedical materials. However, as blood-contacted biomedical device, the intravascular metal stent has a burden with adverse effects on the structural integrity, such as mechanical load during implantation and substrate degradation if a biodegradable metal is used as the substrate. It is unquestionably true that the structural integrity of the coated stent is essential. The adhesion strength between the coating and the substrate positively affects it. Silane and polydopamine (PDA) interstitial layers have been investigated to improve the corrosion resistance, biosafety and adhesion strength. This work addressed this challenge by using PDA as an intermediate and glutaraldehyde as a linking agent to establish a strong link between the polymer coating and the intermediate coating. Compared with PDA-only and glutaraldehyde-linked silane layer, the novel coating displayed a notable increase in adhesion. When compared with the bare Ni-free stainless steel, the performance of the novel coating was not significantly different. This novel chitosan film on the glutaraldehyde linked-PDA interface can be applied to various metallic substrates where synergic bioactive and anticorrosive effects of PDA interstitial coating and chitosan are needed.
18 May 2020 in Journal of Biomedical Materials Research Part B: Applied Biomaterials