Masamichi Nogawa

Mr. Masamichi Nogawa

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 1999 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
AYA Yuhki
A Yuhki
EHE Hatoh
E Hatoh
MNMasamichi Nogawa
Masamichi Nogawa
MMM Miura
M Miura
YSY Shimazaki
Y Shimazaki
STS Takatani
S Takatani

1 August 2007
Verified
Conference Paper
Closed access
TYT. Yamakoshi
T. Yamakoshi
KYK. Yamakoshi
K. Yamakoshi
STS. Tanaka
S. Tanaka
MNMasamichi Nogawa
Masamichi Nogawa
MSM. Shibata
M. Shibata
YHY. Hirose
Y. Hirose
Prolonged periods of driving in monotonous situations may lower a driver's activation state as well as increasing their stress level due to the compulsion to maintain safe driving, which may result in an increased risk of a traffic accident. There is therefore an opportunity for technological assessment of driver physiological status to be applied in-car, hopefully reducing the incidence of potentially dangerous situations. As part of our long-term aim to develop such a system, we describe here the investigation of differential skin temperature measurement as a possible marker of a driver's stress level. 10 healthy male subjects were studied, under environment-controlled conditions, whilst being subjected to simulated monotonous travel at constant speed on a test-course. We acquired measurements of relevant physiological variables, including truncal and peripheral skin temperatures (Ts), beat-by-beat blood pressure (BP), cardiac output (CO), total peripheral resistance (TPR), and normalized pulse volume (NPV) used as an indicator of local peripheral vascular tone. We then investigated the driver's reactivity in terms of cardiovascular haemodynamics and skin temperatures. We found that the simulated monotonous driving produced a gradual drop in peripheral Ts following the driving stress, which, through interpretation of the TPR and NPV recordings, could be explained by peripheral sympathetic activation. On the other hand, the truncal Ts was not influenced by the stress. These findings lead us to suggest that truncal-peripheral differential Ts might be used as a possible index indicative of the driver's stress. Such an index, if decisively validated, would be easy to apply in real driving situations by using radiation thermometer.

1 July 1997 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
TITatsuhiko Iijima
Tatsuhiko Iijima
TITaro Inamoto
Taro Inamoto
MNMasamichi Nogawa
Masamichi Nogawa
STSetsuo Takatani
Setsuo Takatani

3 February 2007 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
STS. Tanaka
S. Tanaka
KMK. Motoi
K. Motoi
MNMasamichi Nogawa
Masamichi Nogawa
KYK. Yamakoshi
K. Yamakoshi
Measurement of physical activity is one of the key subjects in the field of ambulatory cardiovascular monitoring using such as Holter ECG and so called "ambulatory blood pressure monitor (ABPM)". Rehabilitation and gerontology will also be another fields for the application of the activity monitor. From this point of view, we have developed a portable device for monitoring human posture and walking velocity in ambulatory subjects. In this paper are described, a new sensor system for this purpose using three accelerometers and one gyroscope, its availability for the accurate measurement of human posture and walking velocity, and results of preliminary study using a prototype system for ambulatory monitoring.

17 September 2007 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
STShinobu Tanaka
Shinobu Tanaka
MNMasamichi Nogawa
Masamichi Nogawa
TYTakehiro Yamakoshi
Takehiro Yamakoshi
KYKen-Ichi Yamakoshi
Ken-Ichi Yamakoshi
For the noninvasive and accurate measurement of instantaneous blood pressure (BP) in the radial artery, the performance of a device based on the principle of volume-compensation was assessed by comparison with simultaneous measurement of direct (invasive) radial artery pressure in nine healthy subjects. Bias and precision of systolic BP (SBP) and diastolic BP (DBP) derived from Bland-Altman plots of data from the present system and the direct method averaged -0.5 plusmn 2.1 mmHg and 0.6 plusmn 1.8 mmHg respectively, over a wide range of SBP and DBP. These results clearly indicate that, using this system, instantaneous radial artery pressure can be measured noninvasively with high accuracy.

11 July 2005 in IEEE Engineering in Medicine and Biology Magazine
Verified
Journal Article
Closed access
STS. Tanaka
S. Tanaka
SGShumei Gao
Shumei Gao
MNMasamichi Nogawa
Masamichi Nogawa
KYK.-I. Yamakoshi
K.-I. Yamakoshi
A new prototype system for the noninvasive measurement of instantaneous blood pressure (BP) in the human radial artery has been developed. The system is based on the volume-compensation method, but several components were newly designed, namely, a disk-type cuff for local pressurization and a nozzle-flapper-type electro-pneumatic converter (EPC) for the cuff-pressure control. Results of experiments indicated that, using the disk-type cuff, the radial artery could be completely compressed, and the newly devised EPC had sufficient frequency response for BP measurement in humans. It was also found that the prototype system comprising these components was capable of noninvasively measuring instantaneous BP in the human radial artery, not only under rest conditions but also in a stressful condition, such as during the cold pressor test. In conclusion, the newly developed local pressurization technique appears promising as a useful and helpful means for instantaneous BP monitoring over longer periods of time than have previously been possible. Using this method, it is possible to construct an instrument that is more compact and more comfortable for the subject to use than a conventional commercial instrument. Finally, it has been reported that it may be possible to monitor cardiac output continuously by BP waveform analysis. Thus, continuous cardiac output monitoring might be another potential and important application of the newly designed instrument.