The application of interconnected supermacroporous cryogels as support matrices for the purification, separation and immobilization of whole cells and different biological macromolecules has been well reported in literature. Cryogels have advantages over traditional gel carriers in the field of biochromatography and related biomedical applications. These matrices nearly mimic the three-dimensional structure of native tissue extracellular matrix. In addition, mechanical, osmotic and chemical stability of cryogels make them attractive polymeric materials for the construction of scaffolds in tissue engineering applications and in vitro cell culture, separation materials for many different processes such as immobilization of biomolecules, capturing of target molecules, and controlled drug delivery. The low mass transfer resistance of cryogel matrices makes them useful in chromatographic applications with the immobilization of different affinity ligands to these materials. Cryogels have been introduced as gel matrices prepared using partially frozen monomer or polymer solutions at temperature below zero. These materials can be produced with different shapes and are of interest in the therapeutic area. This review highlights the recent advances in cryogelation technologies by emphasizing their biomedical applications to supply an overview of their rising stars day to day.
Identification of pathogenic microorganisms by traditional methods is slow and cumbersome. Therefore, the focus today is on developing new and quicker analytical methods. In this study, a Surface Plasmon Resonance (SPR) sensor with a microcontact imprinted sensor chip was developed for detecting Salmonella paratyphi. For this purpose, the stamps of the target microorganism were prepared and then, microcontact S. paratyphi-imprinted SPR chips were prepared with the functional monomer N-methacryloyl-L-histidine methyl ester (MAH). Characterization studies of the SPR chips were carried out with ellipsometry and scanning electron microscopy (SEM). The real-time Salmonella paratyphi detection was performed within the range of 2.5 × 106–15 × 106 CFU/mL. Selectivity of the prepared sensors was examined by using competing bacterial strains such as Escherichia coli, Staphylococcus aureus and Bacillus subtilis. The imprinting efficiency of the prepared sensor system was determined by evaluating the responses of the SPR chips prepared with both molecularly imprinted polymers (MIPs) and non-imprinted polymers (NIPs). Real sample experiments were performed with apple juice. The recognition of Salmonella paratyphi was achieved using these SPR sensor with a detection limit of 1.4 × 106 CFU/mL. In conclusion, SPR sensor has the potential to serve as an excellent candidate for monitoring Salmonella paratyphi in food supplies or contaminated water and clearly makes it possible to develop rapid and appropriate control strategies.
Over the past few decades, a significant increase in multi-drug-resistant pathogenic microorganisms has been of great concern and directed the research subject to the challenges that the distribution of resistance genes represent. Globally, high levels of multi-drug resistance represent a significant health threat and there is a growing requirement of rapid, accurate, real-time detection which plays a key role in tracking of measures for the infections caused by these bacterial strains. It is also important to reduce transfer of resistance genes to new organisms. The, World Health Organization has informed that millions of deaths have been reported each year recently. To detect the resistant organisms traditional detection approaches face limitations, therefore, newly developed technologies are needed that are suitable to be used in large-scale applications. In the present study, the aim was to design a surface plasmon resonance (SPR) sensor with micro-contact imprinted sensor chips for the detection of Staphylococcus aureus. Whole cell imprinting was performed by N-methacryloyl-L-histidine methyl ester (MAH) under UV polymerization. Sensing experiments were done within a concentration range of 1.0 × 102–2.0 × 105 CFU/mL. The recognition of S. aureus was accomplished by the involvement of microcontact imprinting and optical sensor technology with a detection limit of 1.5 × 103 CFU/mL. Selectivity of the generated sensor was evaluated through injections of competing bacterial strains. The responses for the different strains were compared to that of S. aureus. Besides, real experiments were performed with milk samples spiked with S. aureus and it was demonstrated that the prepared sensor platform was applicable for real samples.
15 August 2021 in International Journal of Polymeric Materials and Polymeric Biomaterials
Bilayer wound dressing systems consisting of various biopolymers have been preferred in biomedical applications due to its enhanced advantages in comparison with conventional systems. The aim of this research was to develop a novel bilayer wound dressing based on gelatin (G) and gellan gum (GG). The bilayer was composed of an upper layer impregnated with antibiotic drug sodium ampicillin and a drug-free lower sponge layer. The bilayer hydrogels were characterized by FTIR, TGA, DSC and SEM analyses including swelling behaviors and hydrolytic degradation tests. To achieve faster healing of the wound by prevention of the bacterial infection, the bilayer hydrogels were developed as antibiotic-releasing vehicles. Herein, release study of sodium ampicillin was performed in PBS to simulate the physiological micro-environment. Additionally, cyto-compatibility tests of L929 fibroblast cells showed the high proliferation and survival through drug-loaded GG and G hydrogels (GG-G-D) after 24h, 48h and 72h incubation. This novel GG-G bilayer hydrogel could be a good candidate as wound dressing. Graphical abstract
Microbial contaminants are responsible for several infectious diseases, and they have been introduced as important potential food- and water-borne risk factors. They become a global burden due to their health and safety threats. In addition, their tendency to undergo mutations that result in antimicrobial resistance makes them difficult to treat. In this respect, rapid and reliable detection of microbial contaminants carries great significance, and this research area is explored as a rich subject within a dynamic state. Optical sensing serving as analytical devices enables simple usage, low-cost, rapid, and sensitive detection with the advantage of their miniaturization. From the point of view of microbial contaminants, on-site detection plays a crucial role, and portable, easy-applicable, and effective point-of-care (POC) devices offer high specificity and sensitivity. They serve as advanced on-site detection tools and are pioneers in next-generation sensing platforms. In this review, recent trends and advances in optical sensing to detect microbial contaminants were mainly discussed. The most innovative and popular optical sensing approaches were highlighted, and different optical sensing methodologies were explained by emphasizing their advantages and limitations. Consequently, the challenges and future perspectives were considered.
24 October 2012 in Journal of Molecular Recognition