Purpose: To evaluate the outcomes of carotid artery stenting (CAS) with Wallstents in a single-center experience. Methods: From January 2003 to December 2013, 1000 carotid artery lesions were treated with Carotid Wallstents under cerebral protection in 877 patients (mean age 71.7±8 years; 621 men). Indications for treatment were de novo lesions (>70% asymptomatic and >60% symptomatic); stenoses following carotid endarterectomy, radiation, or neck surgery; contralateral laryngeal nerve palsy; and high surgical risk. All the patients underwent duplex ultrasound and clinical evaluation during follow-up; radiography was performed when fracture or stent migration was suggested by ultrasound. Results: Procedure success was achieved in 99.3% of patients. Major and minor 30-day adverse events occurred in 2.1% of patients, including stroke (1.8%: 1.3% minor, 0.5% major), myocardial infarction (0.1%), and death (0.2%). Plaque morphology, nature of stenosis, and symptomatic status were significantly associated with the risk of postoperative neurologic events. Restenosis occurred in 3.2% at a mean 45.5-month follow-up and was significantly associated with diabetes, smoking, symptomatic stenosis, de novo stenosis, and calcification (plaque III/IV). No fracture or migration was registered during follow-up. Conclusion: CAS is a valid method for treating carotid artery disease, with very low rates of major adverse events and neurologic complications. The Carotid Wallstent seems to have excellent results, even with complex plaque morphology, and a low incidence of restenosis at follow-up.
Aortic dissection is a life-threatening vascular disease associated with high rates of morbidity and mortality, especially in medically underserved communities. Understanding patients’ blood flow patterns is pivotal for informing evidence-based treatment as they greatly influence the disease outcome. The present study investigates the flow patterns in the false lumen of three aorta dissections (fully perfused, partially thrombosed, and fully thrombosed) in the chronic phase, and compares them to a healthy aorta. Three-dimensional geometries of aortic true and false lumens (TLs and FLs) are reconstructed through an ad hoc developed and minimally supervised image analysis procedure. Computational fluid dynamics (CFD) is performed through a finite volume unsteady Reynolds-averaged Navier–Stokes approach assuming rigid wall aortas, Newtonian and homogeneous fluid, and incompressible flow. In addition to flow kinematics, we focus on time-averaged wall shear stress and oscillatory shear index that are recognized risk factors for aneurysmal degeneration. Our analysis shows that partially thrombosed dissection is the most prone to false lumen degeneration. In all dissections, the arteries connected to the false lumen are generally poorly perfused. Further, both true and false lumens present higher turbulence levels than the healthy aorta, and critical stagnation points. Mesh sensitivity and a thorough comparison against literature data together support the reliability of the CFD methodology. Image-based CFD simulations are efficient tools to assess the possibility of aortic dissection to lead to aneurysmal degeneration, and provide new knowledge on the hemodynamic characteristics of dissected versus healthy aortas. Similar analyses should be routinely included in patient-specific hemodynamics investigations, to plan and design tailored therapeutic strategies, and to timely assess their effectiveness.