Jason Wiebrecht

Mr. Jason Wiebrecht

Cleveland State University, Cleveland, Georgia, USA
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
AGAnthony Clarence Chua Goo
Anthony Clarence Chua Goo
CLCurt A. Laubscher
Curt A. Laubscher
JWJason Wiebrecht
Jason Wiebrecht
RFRyan J. Farris
Ryan J. Farris
JSJerzy Sawicki
Jerzy Sawicki
Exoskeleton technology has undergone significant developments for the adult population but is still lacking for the pediatric population. This paper presents the design of a hip–knee exoskeleton for children 6 to 11 years old with gait abnormalities. The actuators are housed in an adjustable exoskeleton frame where the thigh part can adjust in length and the hip cradle can adjust in the medial-lateral and posterior-anterior directions concurrently. Proper control of exoskeletons to follow nominal healthy gait patterns in a time-invariant manner is important for ease of use and user acceptance. In this paper, a hybrid zero dynamics (HZD) controller was designed for gait guidance by defining the zero dynamics manifold to resemble healthy gait patterns. HZD control utilizes a time-invariant feedback controller to create dynamically stable gaits in robotic systems with hybrid models containing both discrete and continuous dynamics. The effectiveness of the controller on the novel pediatric exoskeleton was demonstrated via simulation. The presented preliminary results suggest that HZD control provides a viable method to control the pediatric exoskeleton for gait guidance.

9 February 2023 in Robotics
Verified
Journal Article
Open access
PDF file
AGAnthony Clarence Chua Goo
Anthony Clarence Chua Goo
JWJason Wiebrecht
Jason Wiebrecht
DWDouglas A Wajda
Douglas A Wajda
JSJerzy Sawicki
Jerzy Sawicki
While several lower-limb exoskeletons have been designed for adult patients, there remains a lack of pediatric-oriented devices. This paper presented a human factor assessment of an adjustable pediatric lower-limb exoskeleton for childhood gait assistance. The hip and knee exoskeleton uses an adjustable frame for compatibility with children 6–11 years old. This assessment evaluates the device’s comfort and ease of use through timed donning, doffing, and reconfiguration tasks. The able-bodied study participants donned the device in 6 min and 8 s, doffed it in 2 min and 29 s, and reconfigured it in 8 min and 23 s. The results of the timed trials suggest that the exoskeleton can be easily donned, doffed, and reconfigured to match the anthropometrics of pediatric users. A 6-min unpowered walking experiment was conducted while the child participant wore the exoskeletal device. Inspection of both the device and participant yielded no evidence of damage to either the device or wearer. Participant feedback on the device was positive with a system usability scale rating of 80/100. While minor improvements can be made to the adjustability indicators and padding placement, the results indicate the exoskeleton is suitable for further experimental evaluation through assistive control assessments.

4 March 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JSJacob A. Strick
Jacob A. Strick
JWJason Wiebrecht
Jason Wiebrecht
RFRyan J. Farris
Ryan J. Farris
JSJerzy Sawicki
Jerzy Sawicki
Accurate detection of gait events, such as heel strike (HS) and toe off (TO), is critical for the implementation of many lower limb exoskeleton control strategies. While underfoot force sensors are commonly used, their limitations have inspired the development of algorithms to detect these events from kinematic information obtained from inertial measurement units (IMUs) placed on limb segments and encoders at the joints. This work presents an adaptive, user-independent approach to gait event detection, using kinematic information from the embedded sensors of an exoskeleton. These included hip and knee joint encoders and a thigh-worn IMU; additionally, event detection only considered ipsilateral data. The algorithm was evaluated in real-time with seven healthy subjects walking in the Indego Explorer exoskeleton on an instrumented treadmill at varying speeds and slopes. The experiment yielded mean gait phase errors of 0.38% ± 1.82% for HS and 0.54% ± 1.14% for TO, at an accuracy of 99.93% over a total of 4104 steps. The results of this validation suggest that the presented algorithm is a viable solution to inertial-based gait event detection for the application of lower limb exoskeleton control. Future directions for this work include evaluating the algorithm for overground walking and for a controller providing gait assistance.

28 April 2025 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
JWJason Wiebrecht
Jason Wiebrecht
JSJacob A. Strick
Jacob A. Strick
RFRyan J. Farris
Ryan J. Farris
JSJerzy T. Sawicki
Jerzy T. Sawicki
Robot-assisted gait rehabilitation is an increasingly common therapeutic intervention for enhancing locomotion and improving quality of life for children with lower-limb mobility impairments. However, there are few systems specifically designed for pediatric use, and those that do exist are largely cumbersome, bulky, and noncustom devices that ultimately reduce therapy effectiveness. This paper introduces the Cable-Driven Joint System (CDJS), a novel approach for pediatric gait rehabilitation that addresses these shortcomings in a lightweight and compact robotic device using the patient's professionally fitted orthosis. The CDJS consists of a 2.1 kg actuation unit that is held by a clinician which delivers assistive torques through a Bowden cable transmission to a 0.3 kg joint mounted to user-custom bracing. This work details an actuator benchtop evaluation, demonstrating a peak torque of 20 N·m, peak velocity of 7.2 rad/s, bandwidth of 9.7 Hz, and a mass moment of inertia of 58.38 kg cm2. An actuator model was developed and evaluated in simulation, showing a strong correlation with the experimental torque data (R-squared = 0.95) and indicating a transmission efficiency of 72%. In-air gait tracking experiments on an emulated subject showed that the CDJS assisted the subject to track a nominal knee trajectory with an average root-mean-squared error of 2.56 deg at a continuous torque of 1.37 N·m. These results suggest that the cable-driven actuator meets the design requirements for use in pediatric gait rehabilitation and is ready for implementation in clinical device trials.