Application of massive data to structural health monitoring (SHM) may lead to serious problems such as difficulty, computational inefficiency, and low damage detectability. This paper proposes innovative hybrid methods in order to detect damage under massive data, ambient vibration, and environmental and/or operational variability. Each of the proposed methods consists of a three-stage algorithm including response modelling via a time series representation, Gaussian mixture model (GMM) for dimensionality reduction, and an outlier detector. Due to the importance of response modelling under ambient vibration, this article employs the combination of AR with ARX called the ARARX model. In the second stage, a GMM is individually fitted to residual samples extracted from ARARX regarding the undamaged and damaged conditions to obtain low-dimensional features from massive data. Eventually, outlier analyses are carried out by the Mahalanobis distance and an auto-associative neural network to make a decision about the occurrence of damage. Two different kinds of threshold limits are also considered to examine the performances of the proposed methods. A large-scale cable-stayed bridge is applied to validate the reliability and effectiveness of these methods with several comparative studies. Results demonstrate that both proposed methods are effective tools for damage detection.
16 January 2021 in Journal of Civil Structural Health Monitoring
Concrete has good strength and durability; however, it suffers from spalling and significant reduction of strength when exposed to fire. This study was aimed to enhance the fire resistance of concrete by applying two different techniques: 1) reinforcing with fiber, and 2) applying a fire-proof coating. For this purpose, mixes were made with steel fiber (SF), glass fiber (GF), and polypropylene fiber (PPF) applied at 0.5-2% of cement weight; in addition to a mix prepared with a 15 mm layer of fireproof coating material and a control mix. All mixes were subjected to elevated temperatures of 200-800 °C, and physical and mechanical properties were evaluated. According to the test results, both techniques were effective in enhancing the fire resistance of concrete mixes. The maximum residual compressive and flexural strengths were obtained for mix containing 0.5% GF, which were 117% and 145% higher than that of the control mix at 800 °C, respectively. Also, concrete with fireproof coating showed up to 76% and 113% higher compressive and flexural strengths compared to that of the control mix, respectively. It was found that addition of fibers in the manufacturing process of the concrete is a more desirable and economically-efficient approach to enhance the fire resistance. However, for an existing concrete structure, applying fireproof coating is the only option and can enhance the fire resistance comparably.