Ziyi Liu

Ms. Ziyi Liu

School of Physics and Optoelectronic Engineering, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou, Zhejiang, China
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
LJLiangchen Jia
Liangchen Jia
XLXiangfeng Liu
Xiangfeng Liu
WXWeiming Xu
Weiming Xu
学许学森 许
学森 许
LLLuning Li
Luning Li
RSRong Shu
Rong Shu
The Mars Surface Composition Detector (MarSCoDe) carried by the Zhurong rover of China’s Tianwen-1 mission uses Laser-Induced Breakdown Spectroscopy (LIBS) to detect and analyze the material composition on Martian surfaces. As one extraterrestrial remote LIBS system, it is necessary to adopt effective and reliable preprocessing methods to correct the spectral drift caused by the changes in environmental conditions, to ensure the analysis accuracy of LIBS scientific data. This paper focuses on the initial spectral drift correction and estimates the accuracy of on-board wavelength calibration on the LIBS calibration target measured by the MarSCoDe LIBS. There may be two cases during the instrument launch and landing, as well as the long-term operation: (a) the initial wavelength calibration relationship can still apply to the on-board LIBS measurement; and (b) the initial wavelength calibration relationship has been changed, and a new on-board calibration is needed to establish the current relationship. An approach of matching based on global iterative registration (MGR) is presented in respect to case (a). It is also compared with the approach of particle swarm optimization (PSO) for case (b). Furthermore, their accuracy is estimated with the comparison to the National Institute of Standards and Technology (NIST) database. The experimental results show that the proposed approach can effectively correct the drift of the on-board LIBS spectrum. The the root-mean-square error (RMSE) of the internal accord accuracy for three channels is 0.292, 0.223 and 0.247 pixels, respectively, compared with the corrected Ti-alloy spectrum and the NIST database, and the RMSE of the external accord accuracy is 0.232, 0.316 and 0.229 pixels, respectively, for other samples. The overall correction accuracy of the three channels is better than one-third of the sampling interval.

28 June 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
ZLZiyi Liu
Ziyi Liu
LLLuning Li
Luning Li
WXWeiming Xu
Weiming Xu
学许学森 许
学森 许
ZCZhicheng Cui
Zhicheng Cui
RSRong Shu
Rong Shu
As part of China’s Tianwen-1 Mars mission, the Mars Surface Composition Detector (MarSCoDe) instrument on the Zhurong rover adopts laser-induced breakdown spectroscopy (LIBS) to perform chemical component detection of the materials on the Martian surface. However, it has always been a challenging issue to achieve high accuracy in LIBS quantification. This study investigated the effect of chemometrics and spectral data preprocessing approaches on LIBS quantification accuracy based on different chemometrics algorithms and diverse preprocessing methods. A total of 2340 LIBS spectra were collected from 39 kinds of geochemical samples by a laboratory duplicate model of the MarSCoDe instrument. The samples and the MarSCoDe laboratory model were placed in a simulated Martian atmosphere environment based on equipment called the Mars-Simulated Detection Environment Experiment Platform (MarSDEEP). To quantify the concentration of MgO in the samples, we employed two common LIBS chemometrics; i.e., partial least squares (PLS) and a back-propagation neural network (BPNN). Meanwhile, in addition to necessary routine preprocessing such as dark subtraction, we used five specific preprocessing approaches, namely intensity normalization, baseline removal, Mg-peak wavelength correction, Mg-peak feature engineering, and concentration range reduction. The results indicated that the performance of the BPNN was better than that of the PLS and that the preprocessing of Mg-peak wavelength correction had the most prominent effect to improve the quantification accuracy. The results of this study are expected to provide inspiration for the processing and analysis of the in situ LIBS data acquired by MarSCoDe on Mars.