Joeri Kok

Dr. Joeri Kok

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
JXJietao Xu
Jietao Xu
SFShorouk Fahmy-Garcia
Shorouk Fahmy-Garcia
MWMarinus A. Wesdorp
Marinus A. Wesdorp
NKNicole Kops
Nicole Kops
LFLucia Forte
Lucia Forte
GOGerjo J.V.M. Van Osch
Gerjo J.V.M. Van Osch
Despite promising clinical results in osteochondral defect repair, a recently developed bi-layered collagen/collagen-magnesium-hydroxyapatite scaffold has demonstrated less optimal subchondral bone repair. This study aimed to improve the bone repair potential of this scaffold by adsorbing bone morphogenetic protein 2 (BMP-2) and/or platelet-derived growth factor-BB (PDGF-BB) onto said scaffold. The in vitro release kinetics of BMP-2/PDGF-BB demonstrated that PDGF-BB was burst released from the collagen-only layer, whereas BMP-2 was largely retained in both layers. Cell ingrowth was enhanced by BMP-2/PDFG-BB in a bovine osteochondral defect ex vivo model. In an in vivo semi-orthotopic athymic mouse model, adding BMP-2 or PDGF-BB increased tissue repair after four weeks. After eight weeks, most defects were filled with bone tissue. To further investigate the promising effect of BMP-2, a caprine bilateral stifle osteochondral defect model was used where defects were created in weight-bearing femoral condyle and non-weight-bearing trochlear groove locations. After six months, the adsorption of BMP-2 resulted in significantly less bone repair compared with scaffold-only in the femoral condyle defects and a trend to more bone repair in the trochlear groove. Overall, the adsorption of BMP-2 onto a Col/Col-Mg-HAp scaffold reduced bone formation in weight-bearing osteochondral defects, but not in non-weight-bearing osteochondral defects.

1 March 2019 in Clinical Biomechanics
Verified
Journal Article
Closed access
JKJoeri Kok
Joeri Kok
AŠAurimas Širka
Aurimas Širka
LGLorenzo Grassi
Lorenzo Grassi
Deepak RainaDeepak Raina
Deepak Raina
ŠTŠarūnas Tarasevičius
Šarūnas Tarasevičius
HIHanna Isaksson
Hanna Isaksson

10 January 2025 in Acta Biomaterialia
Verified
Journal Article
Open access
MPMaria Pierantoni
Maria Pierantoni
KSKunal Sharma
Kunal Sharma
JKJoeri Kok
Joeri Kok
VNVladimir Novak
Vladimir Novak
PEPernilla Eliasson
Pernilla Eliasson
HIHanna Isaksson
Hanna Isaksson
While the number of studies investigating Achilles tendon pathologies has grown exponentially, more research is needed to gain a better understanding of the complex relation between its hierarchical structure, mechanical response, and failure. At the microscale, collagen fibers are, with some degree of dispersion, primarily aligned along the principal loading direction. However, during tension, rearrangements and reorientations of these fibers are believed to occur. As 3D micro-movements are hard to capture, the precise nature of this fiber reorganization remains unknown. This study aimed to visualize and quantify the intricate fiber changes occurring within rat Achilles tendons under tension. Rat tendons were in situ loaded with concurrent synchrotron phase contrast microCT imaging. The results are heterogenous and show that collagen fibers' response to loading is nonuniform and depends on anatomical orientation. Furthermore, damage propagation could be visualized, revealing that in the presence of heterotopic ossification damage proceeds within the ossified deposits rather than at the interface between hard and soft tissues. Our approach could effectively capture the microstructural changes occurring during loading and shows promise in understanding the relation between microstructure and mechanical response for ex-vivo Achilles tendons and other biological tissues. STATEMENT OF SIGNIFICANCE: Achilles tendons endure high mechanical loads during daily motion and physical activities. Understanding the structural and mechanical responses of Achilles tendons to such loads is vital for elucidating their function in health and pathology. We have combined the use of synchrotron phase contrast microCT with in situ mechanical loading contributing a better understanding of the relation between microstructural response and organ scale mechanical properties. The proposed methodology will be valuable for future research into the interplay between structure, mechanics, and pathology of tendons, and for the development of more effective strategies to preserve tendon function and possibly mitigating musculoskeletal disorders.

1 June 2021 in Journal of Biomechanics
Verified
Journal Article
Open access
JKJoeri Kok
Joeri Kok
LGLorenzo Grassi
Lorenzo Grassi
AGAnna Gustafsson
Anna Gustafsson
HIHanna Isaksson
Hanna Isaksson
Low impact falls to the side are the main cause of hip fractures in elderly. Finite element (FE) models of the proximal femur may help in the assessment of patients at high risk for a hip fracture. However, extensive validation is essential before these models can be used in a clinical setting. This study aims to use strain measurements from bilateral digital image correlation to validate an FE model against ex vivo experimental data of proximal femora under a sideways fall loading condition. For twelve subjects, full-field strain measurements were available on the medial and lateral side of the femoral neck. In this study, subject-specific FE models were generated based on a consolidated procedure previously validated for stance loading. The material description included strain rate dependency and separate yield and fracture strain limits in tension and compression. FE predicted fracture force and experimentally measured peak forces showed a strong correlation (R2 = 0.92). The FE simulations predicted the fracture initiation within 3 mm distance of the experimental fracture line for 8/12 subjects. The predicted and measured strains correlated well on both the medial side (R2 = 0.87) and the lateral side (R2 = 0.74). The lower correlation on the lateral side is attributed to the irregularity of the cortex and presence of vessel holes in this region. The combined validation against bilateral full-field strain measurements and peak forces has opened the door for a more elaborate qualitative and quantitative validation of FE models of femora under sideways fall loading.

2 September 2024 in European Journal of Radiology
Verified
Journal Article
Open access
JKJoeri Kok
Joeri Kok
MBMelissa S.A.M. Bevers
Melissa S.A.M. Bevers
BRBert van Rietbergen
Bert van Rietbergen
EOEdwin H.G. Oei
Edwin H.G. Oei
RBRonald Booij
Ronald Booij
Accurate measurements of trabecular bone microarchitecture are required for a proper assessment of bone fragility. Photon-counting detector CT (PCD-CT) has different technical properties than conventional CT, resulting in higher resolution and thereby potentially enabling in-vivo measurement of trabecular microarchitecture. The purpose of this study was to quantify trabecular bone microarchitectural parameters with PCD-CT at varying radiation doses and compare this to µCT as gold standard. Both distal radii, distal tibiae, femoral heads, and two vertebrae were dissected from one human. All specimens were scanned ex-vivo on a PCD-CT system (slice increment 0.1 mm; pixel size 0.1042-0.127 mm) and a µCT system (isotropic voxel size 49-68.4 µm). The radiation doses of the PCD-CT scans were varied from 2.5 to 120 mGy based on the volume CT dose index (CTDIvol32). For the PCD-CT scans, contrast-to-noise ratio and trabecular sharpness were calculated and compared between radiation doses. µCT and PCD-CT scans were registered. The trabecular bone was then segmented from all PCD-CT and µCT scans and split into cubes with 6-mm edge length. For each cube, bone volume over total volume, trabecular thickness, trabecular number, and trabecular heterogeneity were calculated and compared between corresponding PCD-CT and µCT cubes. With increasing dose, contrast-to-noise ratio and trabecular sharpness values increased for the PCD-CT images. Already at the lowest dose, high correlations between the trabecular microarchitectural parameters between µCT and PCD-CT were found (R2 = 0.55-0.95), which improved with increasing radiation dose (R2 = 0.76-0.96 at 20 mGy). PCD-CT can be used to quantify trabecular bone microarchitecture, with accuracy comparable to µCT and at clinically relevant radiation doses.

12 May 2021 in Medical Engineering & Physics
Verified
Journal Article
Open access
JKJoeri Kok
Joeri Kok
ASAurimas Sirka
Aurimas Sirka
YLYang Liu
Yang Liu
ŠTŠarūnas Tarasevičius
Šarūnas Tarasevičius
JBJuozas Belickas
Juozas Belickas
Deepak RainaDeepak Raina
Deepak Raina
Internal fixation failure in hip fractures can lead to reoperation. Calcium sulfate/hydroxyapatite (CaS/HA) is a biomaterial that can be used for augmenting fracture fixation. We aimed to determine whether an injection of 2 ml CaS/HA increases the fixation of a dynamic hip screw inserted in synthetic and human trabecular bone. The study consists of two parts: 1) synthetic bone blocks (n = 74), with three subgroups: empty (cannulated screw, no injection), cannulated, and fenestrated; and 2) osteoporotic human femoral heads (n = 29), with the same subgroups. The heads were imaged using µCT. Bone volume fraction, insertion angle, and head diameter were measured. Pullout tests were performed and peak force, stiffness, and work were measured. The fenestrated group showed increases in pullout strength compared to no injection in the synthetic blocks. The cannulated group showed a higher pullout strength in low-density blocks. In the femoral heads, the variation was larger and there were no significant differences between groups. The bone volume fraction correlated with the peak force and work, and the insertion angle correlated with the stiffness. CaS/HA can improve the fixation of a dynamic hip screw. For clinical use, spreading of the material around the threads of the screw must be ensured.