Jorma Järnstedt

Dr. Jorma Järnstedt


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Jari KangasJari Kangas
Jari Kangas
SKsriram kumar
sriram kumar
HMHelena Mehtonen
Helena Mehtonen
JJJorma Järnstedt
Jorma Järnstedt
RRRoope Raisamo
Roope Raisamo
Virtual reality devices are used for several application domains, such as medicine, entertainment, marketing and training. A handheld controller is the common interaction method for direct object manipulation in virtual reality environments. Using hands would be a straightforward way to directly manipulate objects in the virtual environment if hand-tracking technology were reliable enough. In recent comparison studies, hand-based systems compared unfavorably against the handheld controllers in task completion times and accuracy. In our controlled study, we compare these two interaction techniques with a new hybrid interaction technique which combines the controller tracking with hand gestures for a rigid object manipulation task. The results demonstrate that the hybrid interaction technique is the most preferred because it is intuitive, easy to use, fast, reliable and it provides haptic feedback resembling the real-world object grab. This suggests that there is a trade-off between naturalness, task accuracy and task completion time when using these direct manipulation interaction techniques, and participants prefer to use interaction techniques that provide a balance between these three factors.

9 February 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HRHanna-Riikka Rantamaa
Hanna-Riikka Rantamaa
Jari KangasJari Kangas
Jari Kangas
SKSriram Kumar
Sriram Kumar
HMHelena Mehtonen
Helena Mehtonen
JJJorma Järnstedt
Jorma Järnstedt
RRRoope Raisamo
Roope Raisamo
In medical surgery planning, virtual reality (VR) provides a working environment, where 3D images of the operation area can be utilized. VR allows 3D imaging data to be viewed in a more realistic 3D environment, reducing perceptual problems and increasing spatial understanding. In the present experiment, we compared a mouse, hand tracking, and a combination of a VR stylus and a grab-enabled VR controller as interaction methods in VR. The purpose was to investigate the suitability of the methods in VR for object manipulation and marking tasks in medical surgery planning. The tasks required interaction with 3D objects and high accuracy in the creation of landmarks. The combination of stylus and controller was the most preferred interaction method. According to subjective results, it was considered as the most appropriate because it allows the manipulation of objects in a way that is similar to the use of bare hands. In the objective results, the mouse interaction method was the most accurate.

15 September 2018 in Diagnostics
Verified
Journal Article
Open access
PDF file
JLJussi Leppilahti
Jussi Leppilahti
UHUlla Harjunmaa
Ulla Harjunmaa
JJJorma Järnstedt
Jorma Järnstedt
CMCharles Mangani
Charles Mangani
Marcela HernándezMarcela Hernández
Marcela Hernández
TSTimo Sorsa
Timo Sorsa
A novel qualitative point-of-care test of activated matrix metalloproteinase-8 (aMMP-8) using noninvasive oral rinse sampling procedures has been developed for the early detection of collagen breakdown indicating periodontal tissue destruction. The main object of this study was to assess the reliability of the test in a low-income setting to identify participants with history of periodontal destruction detected as alveolar bone loss (ABL) in radiographs. This cross-sectional study included 486 women who had recently delivered in rural Malawi. The aMMP-8 test and dental panoramic radiographs were taken within 48 h of delivery. The performance of the test in comparison to radiological examinations was tested by following the standards for reporting of diagnostic accuracy studies protocol (STARD) with respective statistical measures and 95% confidence intervals. From the 486 eligible participants, 461 mothers with complete data, aged from 15 to 46 years (mean 24.8, SD 6.0) were included in the analysis. ABL was identified in 116 of 461 participants. There was 56% agreement between the aMMP-8 test results and detected ABL (yes or no) in radiographs. Calculated sensitivity of the test was 80% (72–87%), specificity 48% (43–54%), positive predictive value 34% (31–37%), negative predictive value 88% (83–91%), positive likelihood ratio 1.55 (1.35–1.77), and negative likelihood ratio 0.41(0.28–0.60). The aMMP-8 test sensitivity and negative predictive value to identify the ABL cases were relatively high, but there was additionally a high rate of test-positive results in participants without ABL, especially in young mothers, leading to low overall agreement between the test results and radiological bone loss. Further longitudinal studies are needed to examine if the test positive subjects are in risk of future bone loss before the detectable signs of periodontitis in radiographs.

20 August 2018 in BMC Research Notes
Verified
Journal Article
Open access
PDF file
MPMikko J. Pyysalo
Mikko J. Pyysalo
LPLiisa M. Pyysalo
Liisa M. Pyysalo
JHJenni Hiltunen
Jenni Hiltunen
JJJorma Järnstedt
Jorma Järnstedt
MHMika Helminen
Mika Helminen
TPTanja Pessi
Tanja Pessi
Dental bacterial DNA and bacterial-driven inflammation markers have previously been detected in intracranial aneurysm tissue samples. This study aimed (i) to assess the possible presence of dental infectious foci, (ii) and the possible association between typical odontogenic bacteria and clinical dental findings in patients undergoing pre-operative dental examination before surgical treatment of saccular intracranial aneurysm. Ninety patients with an intracranial aneurysm were recruited to the study, and the patients’ teeth were routinely investigated. Clinical data and bacterial samples from the gingival pockets were collected from a subpopulation of 60 patients. Five typical dental pathogens and total bacteria amounts were measured from gingival samples using real-time quantitative PCR. The amounts of total bacterial and Fusobacterium nucleatum DNA were significantly higher in the patients with ≥ 6 mm gingival pockets than patients without them (p < 0.01 and p < 0.01, respectively). A total of 43% of patients with an aneurysm had gingival pockets of 6 mm or deeper. Dental infectious foci are fairly common in the Finnish population, with the prevalence of severe periodontitis being around 20%. The frequency of chronic dental infections, especially periodontitis seems to be higher in patients with intracranial aneurysm.

15 June 2022 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
HRHanna-Riikka Rantamaa
Hanna-Riikka Rantamaa
Jari KangasJari Kangas
Jari Kangas
MJMaarit Jordan
Maarit Jordan
HMHelena Mehtonen
Helena Mehtonen
JMJohn Mäkelä
John Mäkelä
RRRoope Raisamo
Roope Raisamo
Purpose: In dental implantology, the optimal placement of dental implants is important to meet functional and aesthetic requirements. Planning dental implants in virtual three-dimensional (3D) environment is possible using virtual reality (VR) technologies. The three-dimensional stereoscopic virtual reality environment offers advantages over three-dimensional projection on a two-dimensional display. The use of voice commands in virtual reality environment to replace button presses and other simple actions frees the user’s hands and eyes for other tasks. Methods: Six dentomaxillofacial radiologists experimented using a prototype version of a three-dimensional virtual reality implant planning tool, and used two different tool selection methods, using either only button presses or also voice commands. We collected objective measurements of the results and subjective data of the participant experience to compare the two conditions. Results: The tool was approved by the experts and they were able to do the multiple-implant planning satisfactorily. The radiologists liked the possibility to use the voice commands. Most of the radiologists were willing to use the tool as part of their daily work routines. Conclusion: The voice commands were useful, natural, and accurate for mode change, and they could be expanded to other tasks. Button presses and the voice commands should be both available and used in parallel. The input methods can be further improved based on the expert comments.

1 January 2023 in Dentomaxillofacial Radiology
Verified
Journal Article
Open access
PDF file
ACArnon Charuakkra
Arnon Charuakkra
PMPhattaranant Mahasantipiya
Phattaranant Mahasantipiya
ALAntti Lehtinen
Antti Lehtinen
JKJuha Koivisto
Juha Koivisto
JJJorma Järnstedt
Jorma Järnstedt
Objectives: To compare the cone-beam computed tomography (CBCT) image quality and effective dose between low-dose scanning and standard manufacturer-recommended protocols among different CBCT units. Methods: Three human-equivalent phantoms were scanned using the ultra-low-dose (ULD), low dose (LD), and standard dose (STD) modes of ProMax 3D Mid (Planmeca Oy, Helsinki, Finland) and Orthophos SL (Sirona, Bensheim, German) for the CBCT images. The quality of the dental anatomical images was assessed by four experienced oral and maxillofacial radiologists using a 5-point Likert scale. OnDemand3D (Cybermed Co., Seoul, Korea) was used as the third-party software for viewing. The percentage of absolute agreement was calculated to determine intra- and interrater agreements among the observers. The effective doses for all CBCT scanning protocols were also calculated. Results: The STD protocol yielded a higher image quality than did the ULD and LD protocols in both ProMax 3D Mid and Orthophos SL. The ULD and LD protocols demonstrated an “acceptable-to-good” sense of visual perception of the CBCT images. The visibility scores significantly differed between the ULD and LD and the STD protocols in ProMax 3D Mid and Orthophos SL, except for the 120-kVp setting in ProMax 3D Mid. The average intra- and interrater agreement scores ranged from 0.63 to 0.89 and from 0.44 to 0.76, respectively. The ULD and LD protocols reduced the radiation dose sixfold compared with the STD protocol. Conclusions: High-tube-voltage protocols could remarkably reduce the imaging dose without degrading the image quality. Specifically, ULD and LD CBCT protocols may be adopted as routine practice for diagnosis and treatment planning.