Swathi Naraparaju

Mrs. Swathi Naraparaju


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2020 in Current Green Chemistry
Verified
Journal Article
Closed access
PDF file
BDBarla Karuna Devi
Barla Karuna Devi
SNSwathi Naraparaju
Swathi Naraparaju
CSChaganti Soujanya
Chaganti Soujanya
SGSayan Dutta Gupta
Sayan Dutta Gupta
Green chemistry emphasizes designing novel routes to overcome health and environmental problems that occur during a chemical reaction. Green solvents are used in place of conventional solvents that are hazardous to both human and the environment. Solvents like water, ionic liquids, supercritical CO2, biosolvents, organic carbonates, and deep eutectic mixtures can be used as green solvents. The review focuses on the properties, applications, and limitations of these solvents.

17 July 2018 in Turkish Journal of Pharmaceutical Sciences
Verified
Journal Article
Closed access
SNSwathi Naraparaju
Swathi Naraparaju
PAPani Kumar D. Anumolu
Pani Kumar D. Anumolu
SGsunitha gurrala
sunitha gurrala
RGRajeshwari Galennagari
Rajeshwari Galennagari
The present study was undertaken with the objective to develop and validate a simple spectrofluorimetric method for the simultaneous quantification of tamsulosin hydrochloride and solifenacin succinate. First-derivative synchronous spectrofluorimetry was attempted for the simultaneous quantification of the analytes. Tamsulosin hydrochloride was quantified at a wavelength of 322 nm (zero-crossing wavelength point of solifenacin succinate) and solifenacin succinate was measured at 570 nm (zero-crossing wavelength point of tamsulosin hydrochloride). Calibration plots were constructed over the concentration range of 2-10 µg/mL for tamsulosin hydrochloride and 30-150 µg/mL for solifenacin succinate. The method gave satisfactory results when it is validated for linearity, specificity, accuracy, precision, LOD and LOQ as per the ICH guidelines. The assay values in the commercial formulation were found to be in the percentage range of 95.0 for tamsulosin hydrochloride and 103.5 for solifenacin succinate by the proposed method. These results were well in agreement with their label claim. The proposed synchronous analytical method can be employed for routine quality control analysis of tamsulosin hydrochloride/solifenacin succinate in tablet dose forms.

25 February 2022 in Turkish Journal of Pharmaceutical Sciences
Verified
Journal Article
Closed access
SGsunitha gurrala
sunitha gurrala
SRShiva Raj
Shiva Raj
SCSubrahmanyam Cvs
Subrahmanyam Cvs
DADurga Panikumar Anumolu
Durga Panikumar Anumolu
SNSwathi Naraparaju
Swathi Naraparaju
HNHarika Nizampet
Harika Nizampet
Design of experiments assisted spectrophotometric methods have been established for the quantification of saxagliptin in pharmaceutical formulation via charge transfer complexation and Schiff’s base formation. Box-Behnken design was exploited in method-1, involved the measurement of absorbance of green/blue-colored complex (at 600 nm), formed by the reaction of saxagliptin with 3-methyl-2-benzothiazolinone hydrazone in the presence of ferric chloride. The central composite design was employed in method-2, involved the determination of absorbance of Ruhemann’s purple (at 585 nm), formed by the reaction of the primary amine group of saxagliptin with ninhydrin reagent in presence of sodium hydroxide. Optimization of reaction variables namely, reagent concentration (A), oxidizing agent/alkalinity (B) and reaction/heat time (C) was performed through response surface methodology for the response (Y) i.e. absorbance of colored compound. The reliability of both methods was investigated through validation as per International Council for Harmonisation guidelines. Saxagliptin executed linearity in the concentration range of 0.01-0.25 μg/mL and 1-10 μg/mL by method-1 and 2. A high value of molar absorptivity, low values of Sandell’s sensitivity and limit of detection/limit of quantification divulges the good sensitivity methods. The % assay of saxagliptin in the marketed formulation was found to be 100.27 and 99.86 by method-1 and method-2, respectively. The proposed eco-friendly and economical methods can be routinely employed in quality control for the analysis of saxagliptin in the pharmaceutical dosage forms.

30 November 2020 in Future Journal of Pharmaceutical Sciences
Verified
Journal Article
Open access
PDF file
SNSwathi Naraparaju
Swathi Naraparaju
DTDurai Ananda Kumar Thirumoorthy
Durai Ananda Kumar Thirumoorthy
SGSunitha Gurrala
Sunitha Gurrala
AJAsra Jabeen
Asra Jabeen
PAPani Kumar D. Anumolu
Pani Kumar D. Anumolu
Background: A simple and sensitive spectrophotometric method was developed for the quantitative measurement of dolutegravir in pure form and pharmaceutical formulation. The present method was based on redox reaction between dolutegravir and ferric chloride, which upon complexation with 1,10-phenanthroline formed an orange-colored complex that showed absorption maximum at 520.0 nm.Results: The developed method obeyed linearity in the concentration range of 40.00–140.00 μg/mL. The method was also validated as per International Council for Harmonization guidelines and the results were within acceptance values. The validated method was employed for the determination of dolutegravir in pharmaceutical dosage form and the percentage assay value was found to be 102.5, which is in agreement with its label claimed.Conclusion: The developed redox-based colorimetric method could be used in the routine quality control analysis of dolutegravir present in various pharmaceutical dosage forms.

12 June 2023 in Current Pharmaceutical Analysis
Verified
Journal Article
Closed access
PDF file
BDBarla Karuna Devi
Barla Karuna Devi
KMKuchana Madhavi
Kuchana Madhavi
SNSwathi Naraparaju
Swathi Naraparaju
RDRajeshwari Deverakonda
Rajeshwari Deverakonda
Spectrofluorimetry is an analytical technique with high sensitivity, specificity, and simplicity, and is very economical. Drugs that lack native fluorescence are derivatized with reagents so that highly fluorescent compounds are formed that can be readily detected by spectrofluorimetry. There are different reagents such as 4-chloro-7-nitrobenz-2-oxa-1,3-diazole (NBD-Cl), N- methylnicotinamide chloride (NMNCl), 9-flurenylmethylchloroformate (FMOC-Cl), dansylchloride (DNS-Cl), 3-methyl-2-benzothiazolinone hydrazone hydrochloride (MBTH), 1,2- naphthoquinone-4-sulfonate (NQS), 1,4- benzoquinone, 4-fluro-7-nitrobenzofurazan (NBD-F), ninhydrin, benzoin, N- bromo succinimide (NBS), acetylacetone & HCHO, ortho-phthalaldehyde (OPA), and 2-cyanoacetamide used in spectrofluorimetric determination of the drugs that lack native fluorescence. The present review highlights these reagents with principle, reaction conditions, and their applications.

22 August 2023 in Turkish Journal of Pharmaceutical Sciences
Verified
Journal Article
Closed access
SNSwathi Naraparaju
Swathi Naraparaju
AMAmbati Mukti
Ambati Mukti
DADurga Panikumar Anumolu
Durga Panikumar Anumolu
SCSoujanya Chaganti
Soujanya Chaganti
A new, simple, and affordable spectrofluorimetric method was established for quantification of capecitabine in bulk and in marketed formulations. Native fluorescence of capecitabine in 0.1% (w/v) cetrimide was measured at 386 nm after excitation at 313 nm. A linear relationship between fluorescence intensity and capecitabine concentration was noticed in 0.2-1.0 μg/mL range. The method was supported by checking several validation parameters as stated using International Conference on Harmonization (ICH) guidelines. The limit of detection (LOD) and quantification (LOQ) values (0.032 and 0.096 μg/mL, respectively) and results of validation parameters demonstrated that the method procedure were sensitive, accurate, precise, and reproducible (% relative standard deviation <2.0). The percentage assay in commercial formulation was found to be 99.2, which agrees with ICH guidelines. Due to the above findings, developed method can be successfully adopted for routine analysis of capecitabine in pharmaceutical dosage forms.