Jinzhong Yang

Dr. Jinzhong Yang

Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015 in Investigative Radiology
Verified
Journal Article
Closed access
DMDennis Mackin
Dennis Mackin
XFXenia Bs Fave
Xenia Bs Fave
LZLifei Zhang
Lifei Zhang
DFDavid Bs Fried
David Bs Fried
Jinzhong YangJinzhong Yang
Jinzhong Yang
LCLaurence Edward Court
Laurence Edward Court
Objectives The purpose of this study was to determine the significance of interscanner variability in CT image radiomics studies. Materials and Methods We compared the radiomics features calculated for non–small cell lung cancer (NSCLC) tumors from 20 patients with those calculated for 17 scans of a specially designed radiomics phantom. The phantom comprised 10 cartridges, each filled with different materials to produce a wide range of radiomics feature values. The scans were acquired using General Electric, Philips, Siemens, and Toshiba scanners from 4 medical centers using their routine thoracic imaging protocol. The radiomics feature studied included the mean and standard deviations of the CT numbers as well as textures derived from the neighborhood gray-tone difference matrix. To quantify the significance of the interscanner variability, we introduced the metric feature noise. To look for patterns in the scans, we performed hierarchical clustering for each cartridge. Results The mean CT numbers for the 17 CT scans of the phantom cartridges spanned from −864 to 652 Hounsfield units compared with a span of −186 to 35 Hounsfield units for the CT scans of the NSCLC tumors, showing that the phantom's dynamic range includes that of the tumors. The interscanner variability of the feature values depended on both the cartridge material and the feature, and the variability was large relative to the interpatient variability in the NSCLC tumors for some features. The feature interscanner noise was greatest for busyness and least for texture strength. Hierarchical clustering produced different clusters of the phantom scans for each cartridge, although there was some consistent clustering by scanner manufacturer. Conclusions The variability in the values of radiomics features calculated on CT images from different CT scanners can be comparable to the variability in these features found in CT images of NSCLC tumors. These interscanner differences should be considered, and their effects should be minimized in future radiomics studies.

24 April 2014 in Medical Physics
Verified
Journal Article
Open access
PDF file
GSGregory Sharp
Gregory Sharp
KFKarl D. Fritscher
Karl D. Fritscher
VPVladimir Pekar
Vladimir Pekar
MPMarta Peroni
Marta Peroni
NSNadya Shusharina
Nadya Shusharina
Jinzhong YangJinzhong Yang
Jinzhong Yang
Due to rapid advances in radiation therapy (RT), especially image guidance and treatment adaptation, a fast and accurate segmentation of medical images is a very important part of the treatment. Manu...

3 April 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XFXenia Fave
Xenia Fave
LZLifei Zhang
Lifei Zhang
Jinzhong YangJinzhong Yang
Jinzhong Yang
DMDennis Mackin
Dennis Mackin
PBPeter Balter
Peter Balter
LCLaurence Edward Court
Laurence Edward Court
Radiomics is the use of quantitative imaging features extracted from medical images to characterize tumor pathology or heterogeneity. Features measured at pretreatment have successfully predicted patient outcomes in numerous cancer sites. This project was designed to determine whether radiomics features measured from non–small cell lung cancer (NSCLC) change during therapy and whether those features (delta-radiomics features) can improve prognostic models. Features were calculated from pretreatment and weekly intra-treatment computed tomography images for 107 patients with stage III NSCLC. Pretreatment images were used to determine feature-specific image preprocessing. Linear mixed-effects models were used to identify features that changed significantly with dose-fraction. Multivariate models were built for overall survival, distant metastases, and local recurrence using only clinical factors, clinical factors and pretreatment radiomics features, and clinical factors, pretreatment radiomics features, and delta-radiomics features. All of the radiomics features changed significantly during radiation therapy. For overall survival and distant metastases, pretreatment compactness improved the c-index. For local recurrence, pretreatment imaging features were not prognostic, while texture-strength measured at the end of treatment significantly stratified high- and low-risk patients. These results suggest radiomics features change due to radiation therapy and their values at the end of treatment may be indicators of tumor response.

25 February 2015 in Medical Physics
Verified
Journal Article
Closed access
LZLifei Zhang
Lifei Zhang
DFDavid V. Fried
David V. Fried
XFXenia J. Fave
Xenia J. Fave
LHLuke A. Hunter
Luke A. Hunter
Jinzhong YangJinzhong Yang
Jinzhong Yang
LCLaurence Edward Court
Laurence Edward Court

24 August 2018 in Medical Physics
Verified
Journal Article
Closed access
PDF file
Jinzhong YangJinzhong Yang
Jinzhong Yang
HVHarini Veeraraghavan
Harini Veeraraghavan
SASamuel G. Armato
Samuel G. Armato
KFKeyvan Farahani
Keyvan Farahani
JKJustin S. Kirby
Justin S. Kirby
GSGregory C. Sharp
Gregory C. Sharp

1 December 2015 in Medical Physics
Verified
Journal Article
Closed access
XFXenia Fave
Xenia Fave
DMDennis Mackin
Dennis Mackin
Jinzhong YangJinzhong Yang
Jinzhong Yang
JZJoy Zhang
Joy Zhang
DFDavid Fried
David Fried
LCLaurence Edward Court
Laurence Edward Court