Yong Wang

Dr. Yong Wang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MHMiao Hao
Miao Hao
RZRongan Zhai
Rongan Zhai
YWYong Wang
Yong Wang
CRChanghai Ru
Changhai Ru
BYBin Yang
Bin Yang
Sperm morphology assessment plays a vital role in semen analysis and the diagnosis of male infertility. By quantitatively analyzing the morphological characteristics of the sperm head, midpiece, and tail, it provides essential insights for assisted reproductive technologies (ARTs), such as in vitro fertilization (IVF). However, traditional manual evaluation methods not only rely on staining procedures that can damage the cells but also suffer from strong subjectivity and inconsistent results, underscoring the urgent need for an automated, accurate, and non-invasive method for multi-sperm morphology assessment. To address the limitations of existing techniques, this study proposes a novel method that combines a multi-scale part parsing network with a measurement accuracy enhancement strategy for non-stained sperm morphology analysis. First, a multi-scale part parsing network integrating semantic segmentation and instance segmentation is introduced to achieve instance-level parsing of sperm, enabling precise measurement of morphological parameters for each individual sperm instance. Second, to eliminate measurement errors caused by the reduced resolution of non-stained sperm images, a measurement accuracy enhancement method based on statistical analysis and signal processing is designed. This method employs an interquartile range (IQR) method to exclude outliers, Gaussian filtering to smooth data, and robust correction techniques to extract the maximum morphological features of sperm. Experimental results demonstrate that the proposed multi-scale part parsing network achieves 59.3% APvolp, surpassing the state-of-the-art AIParsing by 9.20%. Compared to evaluations based solely on segmentation results, the integration of the measurement accuracy enhancement strategy significantly reduces measurement errors, with the largest reduction in errors for head, midpiece, and tail measurements reaching up to 35.0%.

30 March 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
MHMiao Hao
Miao Hao
BYBin Yang
Bin Yang
CRChanghai Ru
Changhai Ru
CYChunfeng Yue
Chunfeng Yue
ZHZongjie Huang
Zongjie Huang
CDChangsheng Dai
Changsheng Dai
In order to improve the positioning accuracy of the micromanipulation system, a comprehensive error model is first established to take into account the microscope nonlinear imaging distortion, camera installation error, and the mechanical displacement error of the motorized stage. A novel error compensation method is then proposed with distortion compensation coefficients obtained by the Levenberg–Marquardt optimization algorithm combined with the deduced nonlinear imaging model. The compensation coefficients for camera installation error and mechanical displacement error are derived from the rigid-body translation technique and image stitching algorithm. To validate the error compensation model, single shot and cumulative error tests were designed. The experimental results show that after the error compensation, the displacement errors were controlled within 0.25 μm when moving in a single direction and within 0.02 μm per 1000 μm when moving in multiple directions.

19 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RZRongan Zhai
Rongan Zhai
MHMiao Hao
Miao Hao
YWYong Wang
Yong Wang
CRChanghai Ru
Changhai Ru
JZJunhui Zhu
Junhui Zhu
The removal of cumulus cells from cumulus–oocyte complexes is a critical step in clinical in vitro fertilization. Since the oocyte is partially occluded by the surrounding cumulus cells and individual cumulus cells are small in size, it is difficult for embryologists to assess the oocyte's maturity before cumulus cell removal and to completely remove all the cumulus cells manually . Furthermore, it is easy for the oocyte to become lost inside the micropipette during aspiration due to the inaccuracy of manual control. To deal with these difficulties, a robotic system was developed to completely remove cumulus cells from mature oocytes. In this study, an EPSANet50 network was developed to accurately assess the maturity of oocytes, avoiding the removal of cumulus cells around the immature oocyte. An adaptive controller was designed to accurately position oocytes at the target position, reducing the loss of oocytes inside the micropipette. An improved Yolov5s network was proposed to quantify the number and size of cumulus cells and assess the completeness of cumulus cell removal. The experimental results on mouse cumulus–oocyte complexes showed that the robotic system had a higher success rate (98.0 ± 1.8% vs. 85.3 ± 2.4%) and lower discard rate (4.1 ± 2.7% vs. 19.6 ± 3.5%) than the manual operation. Moreover, a higher amplification rate and lower non-specific rate were also achieved by the robotic system in the subsequent genetic testing procedure, indicating reduced genetic contamination from the cumulus cells.