Thermal barrier coatings (TBCs) suffer from the thermo-chemo-mechanical coupling action of thermal shock and calcium–magnesium–alumina–silicate (CMAS) corrosion. However, the failure mechanism of TBCs under the synergistic effect of thermal shock and CMAS corrosion is still unclear due to a lack of an environmental simulator. Herein, an 8YSZ ceramic coating is deposited on a PtAl bond coating/DD419 nickel-based single crystal superalloy substrate using the electron beam physical vapor deposition (EB-PVD) method. The thermo-chemo-mechanical coupling effect of TBCs is achieved in a self-developed environmental simulator. The interaction of volume expansion induced by the phase transition of ZrO2, structural degradation and thermal fatigue further increases the out-of-plane tensile stress and in-plane shear stress in the ceramic coating, which accelerates the initiation and propagation of surface vertical cracks and horizontal cracks. As multiple surface vertical cracks propagate to the interface and merge with interfacial cracks, the ceramic coating spalls from the substrate.
Thermal barrier coatings (TBCs) have been seriously threatened by calcium-magnesium-alumina-silicate (CMAS) corrosion. The search for novel ceramic coatings for TBCs with excellent resistance to CMAS corrosion is ongoing. Herein, CMAS corrosion resistance behavior and the mechanism of a promising Hf6Ta2O17 ceramic coating for TBCs are investigated. The results show that temperature is the most important factor affecting the CMAS behavior and mechanism. At 1250 °C, the corrosion products are composed of dense reaction products (HfSiO4, CaXHf6−xTa2O17−x) and CMAS self-crystallization products. At 1300 and 1400 °C, the corrosion products are mainly dense CaTa2O6 and HfO2, which prevent further CMAS infiltration.
The non-contact long pulse thermography method is commonly used to detect the defects in thermal barrier coatings (TBCs). The profile of interfacial defect in TBCs can be monitored by infrared camera under the irradiation of the excitation source. Unfortunately, the defect profile is always blurry due to heat diffusion between the defect area and the intact area. It is difficult to quantify the size of defect size in TBCs. In this work, combined with derived one-dimensional heat conduction analytical model, a non-contact long pulse thermography (LPT) method is applied to quantitatively investigate the interface defects in TBCs. Principal component analysis (PCA) and background subtraction method are used to improve the contrast of the defect profile in collected thermal images. By fitting the results between the profile of the interface defect in thermal images and the predicted shape of the model, the interface defect size can be determined. Furthermore, a simple extension of proposed method for interfacial defects with irregular shape is presented. The predicted errors for round defect with diameters of 3 mm, 5 mm and 7 mm are roughly distributed in the range of 3%~6%, which are not affected by the defect diameter.