Agustina Mariana Portu

Mrs. Agustina Mariana Portu

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2015 in International Journal of Radiation Biology
Verified
Journal Article
Closed access
PDF file
APAgustina Mariana Portu
Agustina Mariana Portu
AMAna Julia Molinari
Ana Julia Molinari
STSilvia Inés Thorp
Silvia Inés Thorp
EPEmiliano César Cayetano Pozzi
Emiliano César Cayetano Pozzi
PCPaula Curotto
Paula Curotto
GMGisela Saint Martin
Gisela Saint Martin
Purpose: We previously reported the therapeutic efficacy of Sequential Boron Neutron Capture Therapy (Seq-BNCT), i.e., BPA (boronophenylalanine) – BNCT followed by GB-10 (decahydrodecaborate) – BNCT 1 or 2 days later, in the hamster cheek pouch oral cancer model. We have utilized the neutron autoradiography methodology to study boron microdistribution in tissue. The aim was to use this method to evaluate if the distribution of GB-10 is altered by prior application of BPA-BNCT in Sequential BNCT protocols. Materials and methods: Extensive qualitative and quantitative autoradiography analyses were performed in the following groups: G1 (animals without boron); G2 (animals injected with BPA); G3 (animals injected with GB-10); G4 (same as G3, 24 h after BPA-BNCT); and G5 (same protocol as G4, 48 h interval). Results: A detailed study of boron localization in the different tissue structures of tumor, premalignant and normal tissue in the hamster cheek pouch was performed. GB-10 accumulated preferentially in non-neoplastic connective tissue, whereas for BPA neoplastic cells showed the highest boron concentration. Boron distribution was less heterogeneous for GB-10 than for BPA. In premalignant and normal tissue, GB-10 and BPA accumulated mostly in connective tissue and epithelium, respectively. Conclusions: BPA-BNCT could alter boron microlocalization of GB-10 administered subsequently. Boron targeting homogeneity is essential for therapeutic success.

1 June 2019 in Microscopy and Microanalysis
Verified
Journal Article
Closed access
PDF file
MGMario A. Gadan
Mario A. Gadan
RLRodrigo Lloyd
Rodrigo Lloyd
GMGisela Saint Martin
Gisela Saint Martin
MOMaría S. Olivera
María S. Olivera
LPLucía Policastro
Lucía Policastro
APAgustina Mariana Portu
Agustina Mariana Portu
Our group has reported the imprint formation of biological material on polycarbonate nuclear track detectors by UV-C exposure, which is used as an approach to simultaneously visualize cell imprints and nuclear tracks coming from the boron neutron capture reaction. Considering that the cell nucleus has a higher UV-C absorption than the cytoplasm and that hematoxylin preferentially stains the nucleus, we proposed to enhance the contrast between these two main cell structures by hematoxylin staining before UV-C sensitization. In this study, several experiments were performed in order to optimize UV-C exposure parameters and chemical etching conditions for cell imprint formation using the SK-BR-3 breast cancer cell line. The proposed method improves significantly the resolution of the cell imprints. It allows clear differentiation of the nucleus from the rest of the cell, together with nuclear tracks pits. Moreover, it reduces considerably the UV-C exposure time, an important experimental issue. The proposed methodology can be applied to study the boron distribution independently from the chosen cell line and/or boron compounds.

1 November 2020 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
MEMaría Sol Espain
María Sol Espain
AVAna Mailén Dattoli Viegas
Ana Mailén Dattoli Viegas
VTVerónica Andrea Trivillin
Verónica Andrea Trivillin
GMGisela Saint Martin
Gisela Saint Martin
STSilvia Inés Thorp
Silvia Inés Thorp
APAgustina Mariana Portu
Agustina Mariana Portu

1 March 2016 in Reports of Practical Oncology and Radiotherapy
Verified
Journal Article
Closed access
APAgustina Mariana Portu
Agustina Mariana Portu
ARAndrés Eugenio Rossini
Andrés Eugenio Rossini
MGMario Alberto Gadan
Mario Alberto Gadan
OBOmar Alberto Bernaola
Omar Alberto Bernaola
STSilvia Inés Thorp
Silvia Inés Thorp
GMGisela Saint Martin
Gisela Saint Martin
In this work we present a methodology to produce an "imprint" of cells cultivated on a polycarbonate detector by exposure of the detector to UV C radiation. The distribution and concentration of (10)B atoms in tissue samples coming from BNCT (Boron Neutron Capture Therapy) protocols can be determined through the quantification and analysis of the tracks forming its autoradiography image on a nuclear track detector. The location of boron atoms in the cell structure could be known more accurately by the simultaneous observation of the nuclear tracks and the sample image on the detector. A UV C irradiator was constructed. The irradiance was measured along the lamp direction and at different distances. Melanoma cells were cultured on polycarbonate foils, incubated with borophenylalanine, irradiated with thermal neutrons and exposed to UV C radiation. The samples were chemically attacked with a KOH solution. A uniform irradiation field was established to expose the detector foils to UV C light. Cells could be seeded on the polycarbonate surface. Both imprints from cells and nuclear tracks were obtained after chemical etching. It is possible to yield cellular imprints in polycarbonate. The nuclear tracks were mostly present inside the cells, indicating a preferential boron uptake.

1 November 2015 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
APAgustina Mariana Portu
Agustina Mariana Portu
IPIan Postuma
Ian Postuma
MGMario Alberto Gadan
Mario Alberto Gadan
GMGisela Saint Martin
Gisela Saint Martin
MOMaria Silvina Olivera
Maria Silvina Olivera
Silva BortolussiSilva Bortolussi
Silva Bortolussi

9 July 2015 in Microscopy and Microanalysis
Verified
Journal Article
Closed access
PDF file
APAgustina Mariana Portu
Agustina Mariana Portu
ARAndrés Eugenio Rossini
Andrés Eugenio Rossini
STSilvia Inés Thorp
Silvia Inés Thorp
PCPaula Curotto
Paula Curotto
EPEmiliano César Cayetano Pozzi
Emiliano César Cayetano Pozzi
GMGisela Saint Martin
Gisela Saint Martin
The distribution of boron in tissue samples coming from boron neutron capture therapy protocols can be determined through the analysis of its autoradiography image on a nuclear track detector. A more precise knowledge of boron atom location on the microscopic scale can be attained by the observation of nuclear tracks superimposed on the sample image on the detector. A method to produce an “imprint” of cells cultivated on a polycarbonate detector was developed, based on the photodegradation properties of UV-C radiation on this material. Optimal conditions to generate an appropriate monolayer of Mel-J cells incubated with boronophenylalanine were found. The best images of both cells and nuclear tracks were obtained for a neutron fluence of 1013cm−2, 6 h UV-C (254 nm) exposure, and 4 min etching time with a KOH solution. The imprint morphology was analyzed by both light and scanning electron microscopy. Similar samples, exposed to UV-A (360 nm) revealed no cellular imprinting. Etch pits were present only inside the cell imprints, indicating a preferential boron uptake (about threefold the incubation concentration). Comparative studies of boron absorption in different cell lines andin vitroevaluation of the effect of diverse boron compounds are feasible with this methodology.