Parsa Taheri-Tehrani

Dr. Parsa Taheri-Tehrani


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
PTParsa Taheri-Tehrani
Parsa Taheri-Tehrani
ACAnthony Dorian Challoner
Anthony Dorian Challoner
DHDavid A. Horsley
David A. Horsley
Towards the objective of direct angle measurement using a rate integrating gyroscope (RIG) without a minimum rate threshold and with performance limited only by electrical and mechanical thermal noise, in this paper we present the implementation of a generalized electronic feedback method for the compensation of MEMS gyroscope damping asymmetry (anisodamping) and stiffness asymmetry (anisoelasticity) on a stand-alone digital signal processing (DSP) platform. Using the new method, the precession angle-dependent bias error and minimum rate threshold, two issues identified by Lynch for a MEMS RIG [1] due to anisodamping are overcome. To minimize angle-dependent bias, we augment the electronic feedback force of the amplitude regulator with a non-unity gain output distribution matrix selected to correct for anisodamping. Using this method, we have decreased the angle-dependent bias error by a factor of 12, resulting in a minimum rate threshold of ~3 °/s. To further improve RIG performance, an electronically-induced self-precession rate is incorporated and successfully demonstrated to lower the rate threshold.

1 March 2015
Verified
Conference Paper
Closed access
PTParsa Taheri-Tehrani
Parsa Taheri-Tehrani
OIOleg Izyumin
Oleg Izyumin
IIIgor Izyumin
Igor Izyumin
CAChae H. Ahn
Chae H. Ahn
ENEldwin J. Ng
Eldwin J. Ng
DHDavid A. Horsley
David A. Horsley
We present a demonstration of a whole-angle mode operation of a 0.6 mm single-crystal silicon disk resonator gyroscope (DRG). This device has a Q factor of ~80,000 and a resonant frequency of ~250 kHz and is fabricated in the epi-seal process. Discrete-time control algorithms for rate-integrating gyro operation were implemented based on Lynch's algorithm. Despite the fact that this DRG is over 5 orders of magnitude smaller than the 58 mm HRG, the device's error sources are shown to be accurately modeled by the basic error models developed by Lynch.

17 July 2014 in IEEE Sensors Journal
Verified
Journal Article
Closed access
TSTsanh-Hung Su
Tsanh-Hung Su
SNSarah H. Nitzan
Sarah H. Nitzan
PTParsa Taheri-Tehrani
Parsa Taheri-Tehrani
MKMitchell H. Kline
Mitchell H. Kline
BBBernhard E. Boser
Bernhard E. Boser
DHDavid A. Horsley
David A. Horsley
We present a 2-mm diameter, 35- $\mu $ m-thick disk resonator gyro (DRG) fabricated in silicon with integrated 0.35- $\mu $ m CMOS analog front-end circuits. The device is fabricated in the commercial InvenSense Fabrication MEMS-CMOS integrated platform, which incorporates a wafer-level vacuum seal, yielding a quality factor ( $Q$ ) of 2800 at the DRGs 78-kHz resonant frequency. After performing electrostatic tuning to enable mode-matched operation, this DRG achieves a $55~\mu $ V/°/s sensitivity. Resonator vibration in the sense and drive axes is sensed using capacitive transduction, and amplified using a low-noise, on-chip integrated circuit. This allows the DRG to achieve Brownian noise-limited performance. The angle random walk is measured to be 0.008°/s/ $\surd $ Hz and the bias instability is 20°/h.

9 July 2015 in IEEE Electron Device Letters
Verified
Journal Article
Closed access
SSSoner Sonmezoglu
Soner Sonmezoglu
PTParsa Taheri-Tehrani
Parsa Taheri-Tehrani
CVCarlo Valzasina
Carlo Valzasina
LFLuca G. Falorni
Luca G. Falorni
SZSarah Zerbini
Sarah Zerbini
DHDavid A. Horsley
David A. Horsley
This letter presents a micromachined silicon three-axis gyroscope based on a triple tuning-fork structure utilizing a single vibrating element. The mechanical approach proposed in this letter uses a secondary “auxiliary” mass rather than a major “proof” mass to induce motion in the proof mass frame for Coriolis force coupling to the sense mode. These auxiliary masses reduce the unwanted mechanical coupling of force and motion from the drive mode to the three sense modes. The experimental data show that the bias error due to coupling is reduced by a factor up to 10, and the bias instability of each sense axis is reduced by a factor of up to 3 when the gyroscope is actuated using the auxiliary masses rather than the major masses. The gyroscope exhibits a bias instability of 0.016°/s, 0.004°/s, and 0.043°/s for the x-, y-, and z-sense modes, respectively. Furthermore, initial temperature characterization results show that the gyroscope actuated by the auxiliary masses ensures a better bias instability performance in each sense axis over a temperature range from 10 °C to 50 °C in comparison with the gyroscope actuated by the major masses.

11 November 2013 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
AHAmir Heidari
Amir Heidari
MCMei-Lin Chan
Mei-Lin Chan
HYHsueh-An Yang
Hsueh-An Yang
GJGerardo Jaramillo
Gerardo Jaramillo
PTParsa Taheri-Tehrani
Parsa Taheri-Tehrani
DHDavid A Horsley
David A Horsley

23 February 2016 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SNSarah H. Nitzan
Sarah H. Nitzan
PTParsa Taheri-Tehrani
Parsa Taheri-Tehrani
MDMartial Defoort
Martial Defoort
SSSoner Sonmezoglu
Soner Sonmezoglu
DHDavid A. Horsley
David A. Horsley
This paper addresses the impact of cubic nonlinearity on the operation of a rate-integrating gyroscope (RIG). It is demonstrated that below the bifurcation threshold, cubic nonlinearity results in angle-dependent frequency split between the two resonant modes of the gyroscope, which impacts angle-dependent bias, quadrature error, and controller efficacy in addition to distorting the scale factor due to off-resonant excitation. These errors are experimentally demonstrated using a high-Q disk resonator gyroscope, which are shown to be in close agreement with theory. A method of compensating for angle-dependent frequency error is proposed and experimentally validated. It is demonstrated that mode mismatch can be experimentally reduced to the level of thermal noise, effectively cancelling the effects of nonlinearity and eliminating the distortion of readout angle.