Farzana Mim

Ms. Farzana Mim


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2022 in Cureus
Verified
Journal Article
Open access
NMNusrat Mannan
Nusrat Mannan
RRRuksana Raihan
Ruksana Raihan
UPUmmey Shahnaz Parvin
Ummey Shahnaz Parvin
SASheikh Mohammad Fazle Akbar
Sheikh Mohammad Fazle Akbar
MRMd. Selim Reza
Md. Selim Reza
MKMohammad Jahidur Rahman Khan
Mohammad Jahidur Rahman Khan
Background: Self-collection of nasal swabs for the detection of SARS-CoV-2 RNA by reverse transcription-polymerase chain reaction (RT-PCR) would considerably increase the testing capability and decrease the risk of transmission among healthcare workers (HCW) and the use of personal protective equipment (PPE). Objectives: This study aimed to evaluate the performance of self-collected nasal swabs compared with professionally collected nasopharyngeal (NP) swabs for detection of SARS-CoV-2 RNA by RT-PCR. Materials and methods: We performed a cross-sectional study where the suspected cases of coronavirus disease 2019 (COVID-19) were instructed about the self-collection of nasal swabs from their mid-turbinate. The results were compared to a nasopharyngeal swab collected by a trained healthcare worker in the same patient at the same sitting. Results: We enrolled 100 participants, of which, 69 (69%) were male and 31 (31%) were female. The median age of the study participant was 36 years. Of the participants, 58 (58%) were symptomatic, and the commonest clinical presentation was cough, which was present in 42 (42%) participants. Out of 100 samples, 31 (31%) professionally collected nasopharyngeal swabs and 28 (28%) self-collected nasal swabs were positive for SARS-CoV-2 by RT-PCR. Out of 31 professionally collected positive samples, three samples were negative in self-collection. Out of 28 self-collected positive samples, no sample was negative in the professional collection. The sensitivity and specificity of self-collected nasal swabs compared to professionally collected nasopharyngeal swabs were 90.32% and 100.00%, respectively. The sensitivity of self-collected nasal was 100% when the cycle threshold (Ct) value of the professionally collected NP swab was less than 30. Conclusion: Our study showed that self-collected nasal swabs' sensitivities were similar to professionally collected NP swabs with a high viral load (low Ct value). Hence, this method could be used when the patient is symptomatic and come to the health providers in the early stage of COVID-19 illness.

22 December 2021 in Cureus
Verified
Journal Article
Open access
FMFarzana Mim
Farzana Mim
SRSelim Reza
Selim Reza
MKMohammad Jahidur Rahman Khan
Mohammad Jahidur Rahman Khan
NKNurul Karim
Nurul Karim
MRMohammad A Rahman
Mohammad A Rahman
RBRajib Biswas
Rajib Biswas
The coronavirus disease 2019 (COVID-19) pandemic has manifested into an unprecedented public health crisis. The rapid spread of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has facilitated reagent developers to customize and receive authorization for nucleic acid testing kits in a short period, which would have resulted in some shortcomings in the quality parameters of the kits. Consequently, in-house clinical validations of innovative real-time quantitative polymerase chain reaction (RT-qPCR) kits are required. This research aims to determine the sensitivity, specificity, and accuracy of various RT-qPCR kits available in Bangladesh. A total of 150 samples were obtained from patients with suspected COVID-19 infection when the delta variant was predominant, followed by RNA extraction performed using a nucleic acid isolation kit. Subsequently, three commercially available PCR kits named Sansure (China), STAT-NATⒷ (Sentinel Diagnostics, Italy), and Roche Biochem (Switzerland) were applied to detect SARS-CoV-2. The results showed that the STAT-NATⒷ kit is more sensitive than the other two, as indicated by the cycle threshold (Ct) values of respective genes. STAT-NATⒷ RT-qPCR can detect the ORF1ab gene sensitively (p < 0.001) compared to Sansure. STAT-NATⒷ was also capable of detecting E and RdRp genes more sensitively (p < 0.001) compared to Roche. Regarding specificity, STAT-NATⒷ (95% confidence interval [Cl] = 92.29-99.73%). RT-qPCR showed more accuracy than Sansure (95% Cl = 90.77-99.32%) and Roche (95% Cl = 81.17-94.38%). The area under the curve for E, ORF1ab, and RdRp genes of the STAT NATⒷ PCR kit was 0.952, 0.959, and 0.981, respectively. This study concluded that STAT-NATⒷ is a better diagnostic RT-qPCR kit compared to Sansure and Roche for detecting SARS-CoV-2.

17 April 2022 in Cureus
Verified
Journal Article
Open access
MKMohammad Jahidur Rahman Khan
Mohammad Jahidur Rahman Khan
SSSamshad Jahan Shumu
Samshad Jahan Shumu
FMFarzana Mim
Farzana Mim
RRRuksana Raihan
Ruksana Raihan
NMNusrat Mannan
Nusrat Mannan
PDParoma Deb
Paroma Deb
Background: Healthcare workers (HCWs) at the frontline are confronting a substantial risk of infection during the COVID-19 pandemic. This emerging virus created specific hazards to researchers and laboratory staff in a clinical setting, underlined by rapid and extensive worldwide transmission. Objectives: This study aimed to investigate the prevalence of SARS-CoV-2 infection among COVID-19 reverse transcription-polymerase chain reaction (RT-PCR) laboratory health workers in Bangladesh. Materials and methods: This retrospective study was conducted between October 2 to December 2, 2020. A total of 508 participants, including doctors, scientific officers, medical technologists, and cleaners working in several COVID-19 RT-PCR laboratories, were included in this study. Data were collected from each participant using a semi-structured questionnaire prepared in the format of an anonymous Google form. All statistical analyses were performed using SPSS, version 25.0 (SPSS Inc., Chicago, IL, USA). Results: Out of the 508 participants, 295 tested positive for SARS-CoV-2 RT-PCR. Among the positive cases, 202 were men, and 93 were women, with a median age of 30 years. The most positive cases were medical technologists (53.22%) followed by doctors (28.8%). Out of the 271 symptomatic positive cases, the most typical symptoms were fever (78.5%), fatigue (70%), loss of smell and taste (65%), and cough (64%). Hypertension, obesity, and diabetes were found in 8.8%, 8.8%, and 7.1% positive cases. A + blood group was present in 37% of the positive cases, followed by the B+ blood group (27%) and O+ blood group (25%). Inadequate supply of personal protective equipment (PPE), absence of negative pressure ventilation, laboratory contamination, and no training on molecular test methods were found in 13.8%, 67.8%, 44.7%, and 40.6% of positive cases, respectively. Conclusion: Evaluating the infection status of laboratory HCWs is crucial for drawing attention from the public, providing practical suggestions for government agencies, and increasing protective measures for laboratory HCWs.

24 May 2023 in COVID
Verified
Journal Article
Open access
PDF file
FMFarzana Mim
Farzana Mim
MRMd. Selim Reza
Md. Selim Reza
IKIbrahim Khalil
Ibrahim Khalil
NKNurul Karim
Nurul Karim
HSHussain Md. Shahjalal
Hussain Md. Shahjalal
MHMd. Sabir Hossain
Md. Sabir Hossain
Background: Chronic obstructive pulmonary disease (COPD) is the most prevalent long-term respiratory condition. Patients with COPD experience detrimental effects of COVID-19 infection. Objective: To figure out whether COPD is a risk factor influencing the progression of COVID-19 and to explore the clinical value of laboratory biomarkers to assess the severity of COVID-19 in patients with COPD comorbidity. Methods: In total, 1572 participants aged 35 to 70 years were enrolled to a tertiary hospital in Bangladesh between March 2022 and October 2022. Participants were categorized into four groups: (1) control, (2) COPD, (3) COVID-19, and (4) COVID-19 with COPD, and blood levels of clinical laboratory markers were assessed to analyze how these markers differ among the study groups. Results: COVID-19 patients with COPD had a significantly lower level of sodium (131.81 ± 2.8 mmol/L) and calcium (1.91 ± 0.28 mmol/L), and a significantly higher level of NT-proBNP (568.45 ± 207.40 pg/mL), bilirubin (1.34 ± 0.54 mg/dL), fibrinogen (577.27 ± 145.24 mg/dL), D-dimer (2.97 ± 2.25 μg/mL), C-reactive protein (71.08 ± 62.42 mg/L), interleukin-6 (166.47 ± 174.39 pg/mL), and procalcitonin (0.25 ± 0.30 ng/mL) compared to other study groups patients (p < 0.0001). In addition, the GOLD 4 group demonstrated significantly altered clinical parameters among COVID-19 patients with COPD. Furthermore, NT-proBNP, interleukin 6, D-dimer, C-reactive protein, and fibrinogen demonstrated excellent diagnostic performance in predicting disease severity among the COVID-19 patients with COPD, with a cut-off value of 511.2 pg/mL, 51.375 pg/mL, 1.645 μg/mL, 40.2 mg/L, and 510 mg/dL, respectively. Our results also indicate that inflammatory markers had significant positive correlations with the biochemical and coagulation markers in the COVID-19 patients suffering with COPD (p < 0.0001). Conclusions: NT-proBNP, interleukin 6, D-dimer, C-reactive protein, and fibrinogen are the most potential parameters for differentiating severe cases of COVID-19.