Yan He

Ms. Yan He


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YHYan He
Yan He
YZYahui Zhang
Yahui Zhang
XFXiaohua Feng
Xiaohua Feng
SDShuwei Deng
Shuwei Deng
ZWZhiwen Wang
Zhiwen Wang
This paper proposes a new optimized parameter model that enhances the pointing accuracy of moving-platform electro-optical telescopes (MPEOTs). The study begins by comprehensively analyzing the error sources, including the telescope and the platform navigation system. Next, a linear pointing correction model is established based on the target positioning process. To eliminate multicollinearity, stepwise regression is applied to obtain the optimized parameter model. The experimental results show that the MPEOT corrected by this model outperforms the mount model, with pointing errors of less than 50 arcsec for approximately 23 h. In the three tests conducted, the modified azimuth error(s) (RMS) were 14.07″, 12.71″, and 28.93″, and the elevation error(s) (RMS) were 12.94″, 12.73″, and 28.30″, respectively.

16 January 2024 in IEEE Photonics Journal
Verified
Journal Article
Open access
YHYan He
Yan He
YZYahui Zhang
Yahui Zhang
ZWZhiwen Wang
Zhiwen Wang
SDShuwei Deng
Shuwei Deng
To improve the pointing accuracy of mobile photoelectric telescopes with inertial navigation systems (INSs), a modified inertial pointing and control system is proposed, where the inertial measurement units are transferred from the motion platform to the pointing instrument. As a result, the INS is decoupled from the platform. This paper firstly utilizes coordinate transformations to establish the measurement equations for a mobile telescope system with two structures respectively. Next, an exhaustive error analysis is performed, which involves identifying the error sources and corresponding distributions. Accordingly, the Monte Carlo method is adopted to synthesize and evaluate the pointing error. The simulation results indicates that the mobile photoelectric telescopes with improved structures achieve better pointing accuracy without highly accurate shaft angle encoders, thus simplifying the design and affording greater reliability. Specifically, In terms of means, the systematic error is reduced by over 97%; with standard deviation, the elevation random error is reduced by about 62%.

18 September 2024 in IEEE Photonics Journal
Verified
Journal Article
Open access
ZLZhenghao Li
Zhenghao Li
YZYahui Zhang
Yahui Zhang
YHYan He
Yan He
Pointing accuracy, as one of the important indexes to measure the performance of optical tele-scope products, is directly related to the observation quality and efficiency of the telescope, but affected by a variety of complex factors, the timeliness problem of pointing correction affects the smooth progress of the work. In this study, this paper focuses on the error modelling of optical telescope pointing system under limited observation conditions. In this paper, we first explore the changing law of each parameter and the unknown system error. On this basis, assuming that the system is in a stable state, a digital twin modelling model applied to the pointing system of an electro-optical telescope is proposed, which significantly improves the accuracy of the local pointing error correction by means of a limited observing condition: one newly captured star, and simulates and evaluates the feasibility of the twin model by using the experimental data from the external field, which provides the conditions for the evaluation of the maintenance status of the equipment.