Joseph T. Lynch

Dr. Joseph T. Lynch


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Journal of Biomechanics
Verified
Journal Article
Closed access
JLJoseph T. Lynch
Joseph T. Lynch
MSMarco T.Y. Schneider
Marco T.Y. Schneider
DPDiana M. Perriman
Diana M. Perriman
JSJennie M. Scarvell
Jennie M. Scarvell
MPMark R. Pickering
Mark R. Pickering
PSPaul N. Smith
Paul N. Smith


1 January 2021 in The Bone & Joint Journal
Verified
Journal Article
Closed access
JLJoseph T. Lynch
Joseph T. Lynch
DPDiana M. Perriman
Diana M. Perriman
JSJennie M. Scarvell
Jennie M. Scarvell
MPMark R. Pickering
Mark R. Pickering
CGCatherine R. Galvin
Catherine R. Galvin
PSPaul N. Smith
Paul N. Smith
Aims: Modern total knee arthroplasty (TKA) prostheses are designed to restore near normal kinematics including high flexion. Kneeling is a high flexion, kinematically demanding activity after TKA. The debate about design choice has not yet been informed by six-degrees-of-freedom in vivo kinematics. This prospective randomized clinical trial compared kneeling kinematics in three TKA designs. Methods: In total, 68 patients were randomized to either a posterior stabilized (PS-FB), cruciate-retaining (CR-FB), or rotating platform (CR-RP) design. Of these patients, 64 completed a minimum one year follow-up. Patients completed full-flexion kneeling while being imaged using single-plane fluoroscopy. Kinematics were calculated by registering the 3D implant models onto 2D-dynamic fluoroscopic images and exported for analysis. Results: CR-FB designs had significantly lower maximal flexion (mean 116° (SD 2.1°)) compared to CR-RP (123° (SD 1.6°)) and PS-FB (125° (SD 2.1°)). The PS-FB design displayed a more posteriorly positioned femur throughout flexion. Furthermore, the CR-RP femur was more externally rotated throughout kneeling. Finally, individual patient kinematics showed high degrees of variability within all designs. Conclusion: The increased maximal flexion found in the PS-FB and CR-RP designs were likely achieved in different ways. The PS-FB design uses a cam-post to hold the femur more posteriorly preventing posterior impingement. The external rotation within the CR-RP design was surprising and hasn’t previously been reported. It is likely due to the polyethylene bearing being decoupled from flexion. The findings of this study provide insights into the function of different knee arthroplasty designs in the context during deep kneeling and provide clinicians with a more kinematically informed choice for implant selection and may allow improved management of patients' functional expectations. Cite this article: Bone Joint J 2021;103-B(1):105–112.

10 August 2023 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
PHPhillipa E. Hodge
Phillipa E. Hodge
OROwen J. Rabak
Owen J. Rabak
DPDiana M. Perriman
Diana M. Perriman
JSJennie M. Scarvell
Jennie M. Scarvell
PSPaul N. Smith
Paul N. Smith
JLJoseph T. Lynch
Joseph T. Lynch

1 June 2018 in Journal of Biomechanics
Verified
Journal Article
Open access
JSJennie M. Scarvell
Jennie M. Scarvell
CGCatherine R. Galvin
Catherine R. Galvin
DPDiana M. Perriman
Diana M. Perriman
JLJoseph T. Lynch
Joseph T. Lynch
RDRobert W.M. van Deursen
Robert W.M. van Deursen
While several studies describe kinematics of healthy and osteoarthritic knees using the accurate imaging and computer modelling now possible, no systematic review exists to synthesise these data. A systematic review extracted quantitative observational, quasi-experimental and experimental studies from PubMed, Scopus, Medline and Web of Science that examined motion of the bony or articular surfaces of the tibiofemoral joint during any functional activity. Studies using surface markers, animals, and in vitro studies were excluded. 352 studies were screened to include 23 studies. Dynamic kinematics were recorded for gait, step-up, kneeling, squat and lunge and quasi-static squat, knee flexion in side-lying or supine leg-press. Kinematics were described using a diverse range of measures including six degrees of freedom kinematics, contact patterns or the projection of the femoral condylar axis above the tibia. Meta-analysis of data was not possible since no three papers recorded the same activity with the same measures. Visual evaluation of data revealed that knees with osteoarthritis maintained a more adducted position and showed less posterior translation of the lateral femoral condylar axis than healthy knees. Variability in activities and in recording measures produced greater variation in kinematics, than did knee osteoarthritis. Differences in kinematics between osteoarthritic and healthy knees were observed, however, these differences were more subtle than expected. The synthesis and progress of this research could be facilitated by a consensus on reference systems for axes and kinematic reporting.

7 February 2019 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
SESarah H. Ellis
Sarah H. Ellis
DPDiana M. Perriman
Diana M. Perriman
ABAlexander W. R. Burns
Alexander W. R. Burns
TNTeresa M. Neeman
Teresa M. Neeman
JLJoseph T. Lynch
Joseph T. Lynch
PSPaul N. Smith
Paul N. Smith