Purpose: To obtain normative values of angle kappa in a normal population by synoptophore and Orbscan II and to compare the reliability of these devices. Methods: Three hundred consecutive healthy individuals were enrolled in the study. A complete orthoptic and ophthalmologic examination was performed. Synoptophore and Orbscan II corneal topography were used to measure angle kappa. To evaluate the association of the angle kappa and refraction measures, individuals were further classified according to the degree of myopia and hyperopia. The spherical equivalent error measures were grouped into six categories: ⩾−3.00 diopters (D); −2.75 to −1.50 D; −1.25 to −0.50 D; +0.50 to +1.25 D; +1.50 to +2.75 D; and ⩾+3.00 D. Paired t test and Pearson's correlation test were used for statistical analysis. Results: The mean age of the individuals was 28.74±1.63 years (range: 20 to 40 years). The angle kappa values obtained by synoptophore and Orbscan II were normally distributed. In the myopic group, angle kappa values decreased significantly towards negative refractive errors. In contrast, a correlation existed between large positive angles and positive refractive errors in the hyperopic group. Angle kappa values obtained by Orbscan II were significantly higher in all groups when compared to synoptophore ( P <.0001). A significant correlation was noted between synoptophore and Orbscan II measurements (r=0.932, P <.0001). Conclusions: A significant correlation exists between positive refractive errors and large positive angle kappa values. Refractive surgeons must take into account angle kappa, especially in hyperopic patients, to avoid complications related to decentration of the ablation zone. [ J Refract Surg . 2007;23:456–460.]
To compare the efficacy, safety, and long-term results of intraocular pressure (IOP) reduction by diode laser contact cyclophotocoagulation (DCPC) and Ahmed glaucoma valve (AGV) implant in cases of neovascular glaucoma. A total of 66 eyes of 66 patients with neovascular glaucoma were prospectively assigned to either DCPC or AGV implantation. All patients underwent a baseline complete ophthalmologic examination and IOP measurement by Goldmann applanation tonometry before and after 1,3, 6, 12, and 24 months follow-up. Complications and the number of medications were recorded. Mean age of the patients was 60.0±11.7 years (range: 20 to 85) in the DCPC group and 57.2±10.3 years (range: 20 to 85) in the AGV group. The preoperative IOP was 43.4±11.9 mm Hg and 43.3±7.4 mm Hg for the DCPC and AGV group, respectively (P>0.05). The postoperative IOP was 16.5±11.3 mm Hg and 22.09±7.6 mm Hg for the DCPC and AGV groups, respectively (P>0.05) at the last visit. Kaplan-Meier survival analysis showed a probability of success at 24 months of 61.18% and 59.26% for the DCPC and AGV groups (P>0.05). All the patients had a visual acuity of hand movement or worse preoperatively. Visual acuity decreased in 6 eyes (24%) in the DCPC group and 9 eyes (27%) in AGV group. Complications included anterior segment inflammation in 5 eyes (20%), neurotrophic keratitis in 2 eyes (8%), and hypotony in 3 eyes (15%) in the DCPC group and hyphema in 5 eyes (15%) and tube occlusion in 3 eyes (9%) in AGV group. There was no significant difference in the success rate between the DCPC and AGV implantation in neovascular glaucoma treatment. However, DCPC is less time consuming and easier method for lowering IOP in patients with neovascular glaucoma.
Purpose: To compare the long-term follow-up results of the bare sclera technique (BST), limbal-conjunctival autograft technique (LCAT) and amniotic membrane graft technique (AMGT) in primary pterygium excisions. Materials and Methods: In this study, 48 eyes of 48 patients who underwent pterygium surgery using BST (group 1), 63 eyes of 63 patients who underwent pterygium surgery using LCAT (group 2) and 52 eyes of 52 patients who underwent pterygium surgery using AMGT (group 3) were compared with respect to corneal epithelialization, recurrence and complication of the procedures. The mean ages of the groups were 47.88 ± 14.21 years in group 1, 49.63 ± 14.42 years in group 2 and 47.92 ± 15.52 years in group 3. Patients were followed up to 72.39 ± 11.03 months in group 1, 69.91 ± 12.41 months in group 2 and 61.43 ± 9.83 months in group 3. Results: Postoperative corneal epithelialization was completed in 5.62 ± 1.74 days in group 1, 4.33 ± 0.91 days in group 2 and 4.79 ± 1.39 days in group 3. Corneal epithelialization time was earlier in group 2 than in groups 1 (p < 0.01) and 3 (p < 0.05). Recurrences were detected in 19 eyes (39.58%) in group 1, 11 eyes (14.29%) in group 2 and 12 eyes (23.08%) in group 3. The recurrence rate was significantly lower in group 2 than in groups 1 and 3 (p < 0.001). Postoperative complications were not seen in any of the groups. Graft retraction and necrosis were not detected in the LCAT and AMGT groups during the follow-up period. Conclusions: LCAT was found to be a more effective procedure than BST and AMGT, with decreased recurrence rates after pterygium excision. Limbal-conjunctival autograft seems to be a useful treatment in pterygium surgery due to higher success rates and lower recurrence rates. Amniotic membrane grafts may be an alternative surgical technique for pterygium treatment for patients with or without glaucoma who might need glaucoma surgery in the future.
Purpose To establish the intraobserver and interobserver reliability of the rebound tonometer (RBT) in healthy schoolchildren and to test patient tolerance in an unanesthetized eye. Subjects and Methods To examine the reproducibility of the RBT, 2 experienced ophthalmologists undertook 3 consecutive intraocular pressure (IOP) measurements with the RBT without an anesthetic in 304 eyes of 152 healthy schoolchildren. Any pain or discomfort experienced by the children was recorded. Intraobserver and interobserver reliabilities were established by calculating correlation coefficients (r). Results Of the 152 patients, 78 (51.3%) were males and 74 (48.7%) were females. The mean patient age was 11.2±2.6 years (range: 7 to 15 y). Mean IOP values obtained by examiners 1 and 2 were 16.48±2.82 mm Hg and 17.27±3.27 mm Hg for the right eyes and 17.15±3.36 mm Hg and 17.06±3.21 mm Hg for the left eyes. Intraobserver correlation coefficients for examiner 1 were 0.970 for the right eyes and 0.974 for the left eyes. For examiner 2, intraobserver correlation coefficients were 0.963 for the right eyes and 0.970 for the left eyes. The interobserver correlation coefficients were 0.798 for the right eyes and 0.858 for the left eyes (all P<0.0001). With the RBT, 98.6% of the subjects felt no pain and/or discomfort. Conclusions Measurement of IOP with the RBT is a highly reproducible method in schoolchildren showing high intraobserver and interobserver correlation and it seems to be very comfortable when performing IOP measurements in schoolchildren without an anesthetic.