JIN Qing-Hui

Prof. JIN Qing-Hui


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2021 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
YCYuemeng Cheng
Yuemeng Cheng
Kan WangKan Wang
Kan Wang
HXHao Xu
Hao Xu
TLTangan Li
Tangan Li
JQJIN Qing-Hui
JIN Qing-Hui
DCDaxiang Cui
Daxiang Cui

1 September 2019 in Talanta
Verified
Journal Article
Closed access
JYJinchuan Yang
Jinchuan Yang
Kan WangKan Wang
Kan Wang
HXHao Xu
Hao Xu
WYWenqiang Yan
Wenqiang Yan
JQJIN Qing-Hui
JIN Qing-Hui
DCDaxiang Cui
Daxiang Cui

1 December 2015 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
XBXiaojun Bian
Xiaojun Bian
FJFengxiang Jing
Fengxiang Jing
GLGang Li
Gang Li
XFXiaoyun Fan
Xiaoyun Fan
CJChunping Jia
Chunping Jia
JZJianlong Zhao
Jianlong Zhao

18 August 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
JSJianbo Shao
Jianbo Shao
LWLei Wu
Lei Wu
JWJianzhang Wu
Jianzhang Wu
YZYunhuan Zheng
Yunhuan Zheng
HZHui Zhao
Hui Zhao
JZJianlong Zhao
Jianlong Zhao
For a comprehensive understanding of cells or tissues, it is important to enable multiple studies under the controllable microenvironment of a chip. In this report, we present an integrated microfluidic cell culture platform in which endothelial cells (ECs) are under static conditions or exposed to a pulsatile and oscillatory shear stress. Through the integration of a microgap, self-contained flow loop, pneumatic pumps, and valves, the novel microfluidic chip achieved multiple functions: pulsatile and oscillatory fluid circulation, cell trapping, cell culture, the formation of ECs barrier, and adding shear stress on cells. After being introduced into the chip by gravity, the ECs arranged along the microgap with the help of hydrodynamic forces and grew in the microchannel for more than 7 days. The cells proliferated and migrated to form a barrier at the microgap to mimic the vessel wall, which separated the microenvironment into two compartments, microchannel and microchamber. An optimized pneumatic micropump was embedded to actuate flow circulation in a self-contained loop that induced a pulsatile and oscillatory shear stress at physiological levels on the ECs in the microchannel. All the analyses were performed under either static or dynamic conditions. The performance of the barrier was evaluated by the diffusion and distribution behaviors of fluorescently labeled albumin. The permeability of the barrier was comparable to that in traditional in vitro assays. The concentration gradients of the tracer formed in the microchamber can potentially be used to study cell polarization, migration and communications in the future. Additionally, the morphology and cytoskeleton of the ECs response to the pulsatile and oscillatory shear stress were analyzed. The microfluidic chip provided a multifunctional platform to enable comprehensive studies of blood vessels at the cell or tissue level.

21 January 2021 in The Analyst
Verified
Journal Article
Closed access
PDF file
CZChujun Zheng
Chujun Zheng
Kan WangKan Wang
Kan Wang
WZWei Zheng
Wei Zheng
YCYuemeng Cheng
Yuemeng Cheng
TLTangan Li
Tangan Li
DCDaxiang Cui
Daxiang Cui
Schematic of two main research directions of lateral flow assays for nucleic acid detection.

10 December 2009 in The Analyst
Verified
Journal Article
Closed access
PDF file
MLMeiying Liu
Meiying Liu
CJChunping Jia
Chunping Jia
YHYunyan Huang
Yunyan Huang
XLXinhui Lou
Xinhui Lou
SYShihua Yao
Shihua Yao
JXJiaqing Xiang
Jiaqing Xiang
A highly sensitive protein detection method based on a novel enzyme-labeled gold nanoparticle (AuNP) probe has been developed. In this method, we firstly prepared the enzyme-labeled AuNP probe by coating AuNP with antibody, single-stranded DNA (ssDNA), and horseradish peroxidase (HRP). Magnetic microparticle (MMP) functionalized with another antibody was used as capture probe. Then, target protein was sandwiched by the enzyme-labeled AuNP probe and the capture probe through immunoreaction. The target immunoreaction event could be sensitively transduced via the enzymatically amplified optical signal. By using this strategy, carcinoembryonic antigen (CEA), as a model protein, was detected with high sensitivity and good specificity. The detection limit for this approach was 12 ng L−1, which was approximately 130-fold more sensitive than the conventional enzyme-linked immunosorbent assay (ELISA). The practical application of the proposed immunoassay was carried out for determination of CEA in serum samples. The demonstrated capability of the proposed method shows potentially applications for early diagnoses of diseases.