Noura Alothman

Dr. Noura Alothman

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in Journal of Otology
Verified
Journal Article
Open access
NANoura Alothman
Noura Alothman
REReem Elbeltagy
Reem Elbeltagy
RMReem Mulla
Reem Mulla
Newborn hearing screening (NHS) programs are essential to identify hearing loss early in life and to improve outcomes in children. In Saudi Arabia, the national NHS program has been operational since 2016; however, few studies have evaluated its status, and none have covered all provinces across the country. This cross-sectional retrospective study provides an overview of the program's status across all provinces, focusing on screening coverage rates, referral/fail rates, and follow-up procedures. In 2021, 199,034 newborns were screened, with a coverage rate of 92.6% and an overall referral/fail rate of 1.87%. These performance measures provide a foundation for future progress and improvements. This study highlights the importance of ongoing efforts to enhance the program's effectiveness and sustainability.

Verified
Journal Article
Open access
PDF file
NANoura Alothman
Noura Alothman
FAFida Almuhawas
Fida Almuhawas
RBReem Badghaish
Reem Badghaish
AAAl Hanouf Alotaibi
Al Hanouf Alotaibi
SASalman F Alhabib
Salman F Alhabib
AHAbdulrahman Hagr
Abdulrahman Hagr
The effect of insertion depth and position of cochlear implant (CI) electrode arrays on speech perception remains unclear. This study aimed to determine the relationship between cochlear coverage and speech performance in children with prelingual hearing loss with CI. Pure tone audiometry (PTA) and speech audiometry, including speech reception threshold (SRT) using spondee words and speech discrimination score (SDS) using phonetically balanced monosyllabic words, were tested. The Categories of Auditory Performance (CAP) and Speech Intelligibility Rating (SIR) scales were also used. Thirty-one ears were implanted with the FLEX 28 electrode array, and 54 with the FORM 24 were included in the current study. For the studied ear, the mean cochlear duct length was 30.82 ± 2.24 mm; the mean cochlear coverage was 82.78 ± 7.49%. Cochlear coverage was a significant negative predictor for the mean pure tone threshold across frequecnies of 0.5, 1, 2, and 4 kHz (PTA4) (p = 0.019). Cochlear coverage was a significant positive predictor of SDS (p = 0.009). In children with cochlear coverage ≥ 82.78%, SDS was significantly better than in those with coverage < 82.78% (p = 0.04). Cochlear coverage was not a significant predictor of the SRT, CAP, or SIR. In conclusion, the cochlear coverage of the CI electrode array has an impact on the users’ SDS. Further long-term studies with larger sample sizes should be conducted to address the most critical factors affecting CI recipients’ outcomes.

24 July 2023 in International Journal of Pediatric Otorhinolaryngology
Verified
Journal Article
Open access
NANoura Alothman
Noura Alothman
MAMunira Alotaibi
Munira Alotaibi
GAGhadeer Alshawairkh
Ghadeer Alshawairkh
MAMaryam Almutairi
Maryam Almutairi
RARawan Aldosari
Rawan Aldosari
AAAmal Alqhtany
Amal Alqhtany
Newborn hearing screening (NHS) program was officially initiated in Saudi Arabia in 2016. Although the rate of follow-up default is considered one of the major challenges to the NHS program, no studies have investigated the NHS rate of follow-up default and its reasons in Saudi Arabia. This study aimed to investigate the rate of follow-up default in a hospital-based NHS program and the possible reasons for it. All newborns who were delivered at a tertiary hospital-based NHS program between June 2020 and February 2022 were retrospectively included. The number of live births, newborns who passed NHS, newborns who referred NHS, and newborns who did not complete the appropriate screening or diagnostic stages were reviewed. In a prospective study, parents of all newborns who defaulted the follow-up on screening or diagnosis were telephonically interviewed about the reasons for their follow-up default. In total, 2312 newborns were screened. Screening coverage of 96% and referral rate of 0.6% were found, which align well with the international benchmark. The follow-up default was 18%, which was higher than the benchmark. Parents of all newborns who defaulted the follow-up (n = 424) were also included. The most frequent reasons for follow-up default were related to the parents' unawareness of the recommended follow-up screening (39.5%) and their perception that follow-up was not necessary (24.7%). Coronavirus disease 2019 was also reported by 15.8% of the parents as a reason for follow-up default. Lack of knowledge regarding recommendations made for follow-up and the importance of NHS were the most common reasons for default. Reducing follow-up defaults is essential for successful NHS programs, which can be achieved by implementing a tracking system to remind and encourage parents. Further studies are needed to evaluate the national NHS and investigate the reasons for follow-up defaults from different demographic regions in Saudi Arabia.

8 August 2023 in Ear, Nose & Throat Journal
Verified
Journal Article
Open access
AAAsma Alahmadi
Asma Alahmadi
YAYassin Abdelsamad
Yassin Abdelsamad
NANoura Alothman
Noura Alothman
AAAfrah Muteb Alshalan
Afrah Muteb Alshalan
FAFida Almuhawas
Fida Almuhawas
AHAbdulrahman Hagr
Abdulrahman Hagr
Objectives: The present literature review discusses the chronological evolution of Cochlear Implant (CI) activation and its definition among the relevant studies in the literature. In addition, the benefits of standardizing the early activation process in implantation centers worldwide are discussed. Methods: A comprehensive literature search was conducted in the major databases such as PubMed, Scopus, and Embase to retrieve all the relevant articles that reported early activation approaches following CI. Results: The evolution of the timing of early activation after CI has been remarkable in the past few years. Some studies reported the feasibility of early activation 1 day after the CI surgery in their users. Conclusions: Within the last decade, some studies have been published to report the feasibility and outcomes of its early activation. However, the process of early activation was not adequately defined, and no apparent guidelines could be found in the literature.

1 January 2024 in South African Journal of Communication Disorders
Verified
Journal Article
Open access
PDF file
NANoura Alothman
Noura Alothman
Ahmad A. AlanaziAhmad A. Alanazi
Ahmad A. Alanazi
Background: Hearing loss in children is a global concern. Early identification and intervention are critical for minimising the adverse effects of hearing loss. Despite the implementation of hearing screening programmes in Saudi Arabia, more research is needed on the audiological profiles of first-grade students. Objectives: This study aimed to characterize the audiological profile of first-grade students in Saudi Arabia and to raise awareness among parents, schools, and decision-makers about the need for hearing screening programs and the implementation of an effective monitoring and management system in the country. Method: This cross-sectional descriptive study assessed the audiological profile of 308 first-grade students in Riyadh, the capital of Saudi Arabia, using pure-tone audiometry (PTA) and tympanometry. Additionally, two questionnaire-based assessments, one for parents and one for the home teacher, were developed to predict students who failed PTA. Results: Among the students screened, 26.3% failed PTA. Tympanometry identified abnormal middle ear function in 30.5% of the students. The discrimination capacity of both questionnaires in identifying students who failed PTA screening was poor. Conclusion: A 26.3% prevalence rate of PTA screening failure, and a 30.5% of middle ear pathologies were noted. Both parent and teacher questionnaires were ineffective tools for identifying hearing loss among first-grade children who failed PTA screening. Contribution: This pilot study recommends that primary schools incorporate hearing screening as a regular practice of their preventative healthcare system. The study emphasises the importance of establishing international standards for school-based hearing screening to enhance its efficacy and develop more effective hearing screening questionnaires.

23 May 2024 in International Journal of Pediatric Otorhinolaryngology
Verified
Journal Article
Open access
NANoura Alothman
Noura Alothman
YAYassin Abdelsamad
Yassin Abdelsamad
FAFida Almuhawas
Fida Almuhawas
HAHussain Allami
Hussain Allami
AHAbdulrahman Hagr
Abdulrahman Hagr
Objectives: The newborn hearing screening (NHS) program was globally established for early hearing loss (HL) identification and intervention. Early intervention is essential to minimize or prevent the negative consequences of HL. In Saudi Arabia, the NHS was officially implemented in 2016. Currently, its impact on the timing of cochlear implantations (CIs) in Saudi Arabia remains unclear, and information on potential hospital-related delays affecting early implantation is lacking. Thus, this study aimed to evaluate the effect of implementing the NHS on age at CI in children with prelingual deafness in a CI center in Saudi Arabia, and to evaluate the hospital timing in the CI process. Methods: All pediatric CI users who presented for the first time to the CI committee (CIC) at a tertiary center and received their implants between 2015 and 2022 were enrolled in this study. Date of birth (DOB), date of presentation to the CI committee (DOCIC), and date of CI surgery (DOCIS) were retrospectively reviewed. Results: In total, 304 CI children were included in the analysis. Approximately 55 % of the children (n = 167) were screened for HL through the NHS, whereas 45 % of the children (n = 137) were born before the launch of the NHS. Both age at the presentation to the CIC (i.e. difference between DOCIC and DOB) and age at implantation (i.e. difference between DOCIS and DOB) were significantly earlier in children who were screened for HL through the NHS than those who were not screened (P < 0.0001). The time difference between the DOCIC and DOCIS was not significantly different between the screened and unscreened children (P > 0.05). Conclusion: The implementation of the NHS in the tertiary center has a significant positive effect on age at presentation to the CIC and age at implantation, but not on the actual CI surgery. Further research is needed to reduce the hospital delays before the actual surgery in order to increase the likelihood of children receiving implantation early in their life.