SARA MARTINEZ CASTRO

Dr. SARA MARTINEZ CASTRO

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2019 in Critical Care
Verified
Journal Article
Open access
PDF file
Gerardo AguilarGerardo Aguilar
Gerardo Aguilar
RFRafael Ferriols
Rafael Ferriols
SCSARA MARTINEZ CASTRO
SARA MARTINEZ CASTRO
CECarlos Ezquer-Garin
Carlos Ezquer-Garin
EPErnesto Pastor
Ernesto Pastor
DNDavid Navarro
David Navarro

24 September 2021 in Respiratory Care
Verified
Journal Article
Closed access
PDF file
SCSARA MARTINEZ CASTRO
SARA MARTINEZ CASTRO
FNFrancisco Javier Belda Nacher
Francisco Javier Belda Nacher
CNCarlos Delgado Navarro
Carlos Delgado Navarro
JBJaume Puig Bernabeu
Jaume Puig Bernabeu
BACKGROUND: The growing number of patients on home mechanical ventilation has driven considerable progress in the performance and functionality of ventilators, with features comparable with those used in the ICU. However, a publication gap exists in the evaluation and comparison of their performance and each ventilator choice depends on machine characteristics defined by manufacturers. METHODS: We bench tested 8 home-care ventilators that are currently available: Monnal T50, EOVE EO-150, Puritan Bennet 560, Weinmann, PrismaVent 50, Trilogy Evo, Astral 150, and Vivo 60 by using an active lung model. These devices were tested under 18 experimental conditions that combined 3 variables: respiratory mechanics, ventilatory mode, and inspiratory muscle effort. The volume delivered, trigger response, pressurization capacity, and synchronization were analyzed. RESULTS: Significant differences were observed in the performance among the devices. Decreased inspiratory muscle effort caused changes in the delivered volume, which worsened the response-to-trigger time, pressurization capacity, and synchronization. Increased pressure support favored the development of asynchronies. All the ventilators developed asynchronies under at least 1 set of conditions, but the EOVE and Trilogy Evo ventilators showed the fewest asynchronies during the experimental conditions studied. CONCLUSIONS: Great variability in terms of technical performance was observed among the 8 home-care ventilators analyzed. Asynchronies became a major issue when home mechanical ventilation was used under higher pressure-support values and lower muscle efforts. Our results may prove to be useful in helping choose the best suited machine based on a patient’s clinical therapy needs.

31 July 2023 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
SCSARA MARTINEZ CASTRO
SARA MARTINEZ CASTRO
FNFrancisco Javier Belda Nacher
Francisco Javier Belda Nacher
JBJaume Puig Bernabeu
Jaume Puig Bernabeu
MDMarina B Soro Domingo
Marina B Soro Domingo
CNCarlos Delgado Navarro
Carlos Delgado Navarro
HPHéctor Ortega Pons
Héctor Ortega Pons
Global pandemic due to COVID-19 has increased the interest for ventilators´ use worldwide. New devices have been developed and older ones have undergone a renewed interest, but we lack robust evidence about performance of each ventilator to match appropriate device to a given patient and care environment. The aim of this bench study was to investigate the performance of six devices for noninvasive ventilation, and to compare them in terms of volume delivered, trigger response, pressurization capacity and synchronization in volume assisted controlled and pressure support ventilation. All ventilators were tested under thirty-six experimental conditions by using the lung model ASL5000® (IngMar Medical, Pittsburgh, PA). Two leak levels, two muscle inspiratory efforts and three mechanical patterns were combined for simulation. Trigger function was assessed by measurement of trigger-delay time. Pressurization capacity was evaluated as area under the pressure–time curve over the first 500 ms after inspiratory effort onset. Synchronization was evaluated by the asynchrony index and by incidence and type of asynchronies in each condition. All ventilators showed a good performance, even if pressurization capacity was worse than expected. Leak level did not affect their function. Differences were found during low muscle effort and obstructive pattern. In general, Philips Trilogy Evo/EV300 and Hamilton C3 showed the best results. NIV devices successfully compensate air leaks but still underperform with low muscle effort and obstructive lungs. Clinicians´ must have a clear understanding of the goals of NIV both for devices´ choice and set main parameters to achieve therapy success.

10 January 2020 in Critical Care
Verified
Journal Article
Open access
PDF file
Gerardo AguilarGerardo Aguilar
Gerardo Aguilar
RFRafael Ferriols
Rafael Ferriols
SCSARA MARTINEZ CASTRO
SARA MARTINEZ CASTRO
CECarlos Ezquer-Garin
Carlos Ezquer-Garin
EPErnesto Pastor
Ernesto Pastor
DNDavid Navarro
David Navarro

5 September 2024 in BMJ Open
Verified
Journal Article
Open access
PDF file
MTManuel Taboada
Manuel Taboada
AEAna Estany-Gestal
Ana Estany-Gestal
JFJorge Fernández
Jorge Fernández
OVOlalla Vázquez vazquez-cancela
Olalla Vázquez vazquez-cancela
APAzucena Pajares
Azucena Pajares
TCTeresa Cabaleiro
Teresa Cabaleiro
Introduction Compared with the operating room, tracheal intubations in the intensive care unit (ICU) are associated with worsened glottic view, decreased first-time success rate and increase in the technical difficulty of intubation and incidence of complications. Videolaryngoscopes (VLs) have been proposed to improve airway management, and while recent studies have confirmed that VLs improve intubation conditions in this patient population, there remains a lack of clarity regarding the selection between a standard Macintosh blade or a hyperangulated one, to determine which yields the best outcomes. The purpose of this study was to compare successful intubation on the first attempt with the Macintosh VL versus the hyperangulated VL during tracheal intubation in ICU patients. We hypothesise that tracheal intubation using the hyperangulated VL will improve the frequency of successful intubation on the first attempt. Methods and analysis The INtubation VIdeolaryngoscopy BLADE-ICU trial is a prospective, multicentre, open-label, interventional, randomised, controlled superiority study conducted in 29 ICUs in Spain. Patients will be randomly assigned in a 1:1 ratio to undergo intubation using a Macintosh VL (control group) or a hyperangulated VL (experimental group) for the first intubation attempt. The primary outcome is successful intubation on the first attempt. The secondary outcomes include the time to intubation, attempts for successful intubation, laryngoscopic vision assessed with the modified Cormack-Lehane scale, the need for adjuvant airway devices for intubation, difficulty assessed by the anaesthesiologist and complications during tracheal intubation. Enrolment began on 1 May 2024 and is expected to be completed in 2025. Ethics and dissemination The study protocol was approved on 29 February 2024, by the Ethics Committee of Galicia (CEImG, code No. 2024-031). The results will be submitted for publication in a peer-reviewed journal. Trial registration number NCT06322719.

22 April 2022 in Research Square
Verified
Preprint
Open access
PDF file
SCSARA MARTINEZ CASTRO
SARA MARTINEZ CASTRO
FNFrancisco Javier Belda Nacher
Francisco Javier Belda Nacher
JBJaume Puig Bernabeu
Jaume Puig Bernabeu
MDMarina Soro Domingo
Marina Soro Domingo
CNCarlos Delgado Navarro
Carlos Delgado Navarro
HPHéctor Ortega Pons
Héctor Ortega Pons
Background: Global pandemic due to COVID-19 has increased the interest for ventilators´ use worldwide. New devices have been developed and older ones have undergone a renewed interest, but we lack robust evidence about performance of each ventilator to match appropriate device to a given patient and care environment.Methods: The aim of this bench study was to investigate the performance of six devices for noninvasive ventilation, and to compare them in terms of volume delivered, trigger response, pressurization capacity and synchronization in volume assisted controlled and pressure support ventilation. All ventilators were tested under thirty-six experimental conditions by using the lung model ASL5000® (IngMar Medical, Pittsburgh, PA). Two leaks levels, two muscle inspiratory efforts and three mechanical patterns were combined for simulation. Trigger function was assessed by measurement of trigger-delay time. Pressurization capacity was evaluated as the net area under the pressure-time curve over the first 500 ms after inspiratory effort onset. Synchronization was evaluated by the asynchrony index and by the incidence and type of asynchronies in each condition. Results: All ventilators showed a good performance, even if pressurization capacity was worse than expected. Leak level did not affect their function. Differences were found during low muscle effort and obstructive pattern. In general, Philips EV300 and Hamilton C3 showed the best results.Conclusions: NIV devices successfully compensate air leaks but still underperform with low muscle effort and obstructive lungs. Clinicians´ must have a clear understanding of the goals of NIV both for devices´ choice and set main parameters to achieve therapy success.