Christian Mitschke

Dr. Christian Mitschke

Chemnitz University of Technology
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2017 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
CMChristian Mitschke
Christian Mitschke
FZFalk Zaumseil
Falk Zaumseil
TMThomas L. Milani
Thomas L. Milani
Increasingly, inertial sensors are being used for running analyses. The aim of this study was to systematically investigate the influence of inertial sensor sampling frequencies (SF) on the accuracy of kinematic, spatio-temporal, and kinetic parameters. We hypothesized that running analyses at lower SF result in less signal information and therefore the inability to sufficiently interpret measurement data. Twenty-one subjects participated in this study. Rearfoot strikers ran on an indoor running track at a velocity of 3.5 ± 0.1 ms-1. A uniaxial accelerometer was attached at the tibia and an inertial measurement unit was mounted at the heel of the right shoe. All sensors were synchronized at the start and data was measured with 1000 Hz (reference SF). Datasets were reduced to 500, 333, 250, 200, and 100 Hz in post-processing. The results of this study showed that a minimum SF of 500 Hz should be used to accurately measure kinetic parameters (e.g. peak heel acceleration). In contrast, stride length showed accurate results even at 333 Hz. 200 Hz were required to calculate parameters accurately for peak tibial acceleration, stride duration, and all kinematic measurements. The information from this study is necessary to correctly interpret measurement data of existing investigations and to plan future studies.

5 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
CMChristian Mitschke
Christian Mitschke
PKPierre Kiesewetter
Pierre Kiesewetter
TMThomas L. Milani
Thomas L. Milani
Previous studies have used accelerometers with various operating ranges (ORs) when measuring biomechanical parameters. However, it is still unclear whether ORs influence the accuracy of running parameters, and whether the different stiffnesses of footwear midsoles influence this accuracy. The purpose of the present study was to systematically investigate the influence of OR on the accuracy of stride length, running velocity, and on peak tibial acceleration. Twenty-one recreational heel strike runners ran on a 15-m indoor track at self-selected running speeds in three footwear conditions (low to high midsole stiffness). Runners were equipped with an inertial measurement unit (IMU) affixed to the heel cup of the right shoe and with a uniaxial accelerometer at the right tibia. Accelerometers (at the tibia and included in the IMU) with a high OR of ±70 g were used as the reference and the data were cut at ±32, ±16, and at ±8 g in post-processing, before calculating parameters. The results show that the OR influenced the outcomes of all investigated parameters, which were not influenced by tested footwear conditions. The lower ORs were associated with an underestimation error for all biomechanical parameters, which increased noticeably with a decreasing OR. It can be concluded that accelerometers with a minimum OR of ±32 g should be used to avoid inaccurate measurements.

19 September 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CMChristian Mitschke
Christian Mitschke
THTobias Heß
Tobias Heß
TMThomas L. Milani
Thomas L. Milani
Accelerometers and gyroscopes are used to detect foot strike (FS), i.e., the moment when the foot first touches the ground. However, it is unclear whether different conditions (footwear hardness or foot strike pattern) influence the accuracy and precision of different FS detection methods when using such micro-electromechanical sensors (MEMS). This study compared the accuracy of four published MEMS-based FS detection methods with each other and the gold standard (force plate) to establish the most accurate method with regard to different foot strike patterns and footwear conditions. Twenty-three recreational runners (12 rearfoot and 11 forefoot strikers) ran on a 15-m indoor track at their individual running speed in three footwear conditions (low to high hardness). MEMS and a force plate were sampled at a rate of 3750 Hz. Individual accuracy and precision of FS detection methods were found which were dependent on running styles and footwear conditions. Most of the methods were characterized by a delay which generally increased from rearfoot to forefoot strike pattern and from high to low midsole hardness. It can be concluded that only one of the four methods can accurately determine FS in a variety of conditions.

27 June 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CMChristian Mitschke
Christian Mitschke
MÖMatthias Öhmichen
Matthias Öhmichen
TMThomas L. Milani
Thomas L. Milani
Gyroscopes have been used in previous studies to measure the peak angular velocity of the shoe or foot in the frontal plane (evVel). However, it is not clear whether different test conditions (footwear hardness or locomotion speed) can influence the accuracy of evVel. The purpose of the present study was to compare the accuracy of gyroscopes and electrogoniometers when measuring evVel and the time until evVel (t_evVel) in 12 different conditions using a single axis gyroscope attached to the heel cap. Twenty-four recreational runners were instructed to walk and run on a 15-m indoor track at four locomotion speeds (1.5, 2.5, and 3.5 m/s, and individual running speed) and in three footwear conditions (low to high hardness). The gyroscope data and electrogoniometer data were sampled at a rate of 1000 Hz. Comparisons between both measurement devices showed small mean differences up to 49.8 ± 46.9 deg/s for evVel and up to 5.3 ± 3.5 ms for t_evVel. Furthermore, strong relationships between gyroscope and electrogoniometer data were found for evVel as well as for t_evVel for all conditions. It can be concluded that gyroscopes can be used to accurately determine evVel and t_evVel under a variety of conditions.

8 August 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PKPierre Kiesewetter
Pierre Kiesewetter
SBSabrina Bräuer
Sabrina Bräuer
RHRalf Haase
Ralf Haase
NNNico Nitzsche
Nico Nitzsche
CMChristian Mitschke
Christian Mitschke
TMThomas L. Milani
Thomas L. Milani
Footwear properties can influence physiological and biomechanical variables, which may lead to positive changes in distance running performance. One innovative development in running shoe technology is adding carbon fiber plates to increase midsole bending stiffness. However, there are only a few studies investigating the influence of shoe conditions on both physiological and biomechanical variables, simultaneously, when running for longer than 5 min or for distances > 1 km. Hence, the purpose of the current study was to investigate the influence of different running shoe concepts with carbon fiber plates on physiological and biomechanical parameters during a 10 km treadmill run. Twenty-three athletes participated in the study, which comprised four measurement days for each subject. On the first day, subjects performed a treadmill exhaustion test to determine maximum oxygen uptake. On the second, third, and fourth days, each subject ran 10 km at 70% of their maximum oxygen uptake in one of three shoe models. Significant differences were found between the shoe conditions for the biomechanical parameters, but not for the physiological parameters. It seems that runners adjusted their running styles to the shoe conditions during the 10 km run to reduce the load on the lower extremities without compromising their endurance performance. These results may have practical implications for runners, coaches, and shoe manufacturers.

1 October 2014 in International Journal of Sports Science & Coaching
Verified
Journal Article
Closed access
CMChristian Mitschke
Christian Mitschke
TMThomas L. Milani
Thomas L. Milani
Many studies investigate kinematic and kinetic aspects of instep and inside soccer kicks to understand these techniques. However, there are currently no studies which show how often these techniques are used in a soccer match. Therefore, soccer games of the UEFA EURO 2012 in the Ukraine and Poland were studied to close this gap. The focus was on which part of the foot or body was used to pass the ball. Length and height of the passes, accuracy, starting position of the pass on field and the change of all these statistics during the whole match were investigated. From all 28271 analysed passes, 59.6% were played in different forms using the inside of the foot, 14.6% with the inner instep, 9.1% with the instep and 16.7% with other body parts, like the outside of the foot, the toes or head.