Rahimi Baharom

Dr. Rahimi Baharom


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2016
Verified
Conference Paper
Closed access
KMKhairul Safuan Muhammad
Khairul Safuan Muhammad
RBRahimi Baharom
Rahimi Baharom
MSMohd Khairul Mohd Salleh
Mohd Khairul Mohd Salleh
DLDylan Lu
Dylan Lu
In this paper, a bridgeless boost rectifier with open circuit fault tolerant capability is proposed. The proposed converter is based on a H-bridge rectifier configuration. It possesses a redundancy feature such that only two out of four switches require to be functional to ensure the continuity of the converter operation with power factor correction (PFC). A detailed analysis of the converter operation under all open circuit faults of the switches are presented. In order to achieve smooth input current waveform, a PWM controller is proposed and developed which combines a conventional average current mode PFC controller with several logic gates and a phase detector. An experimental prototype is developed and tested to verify the converter performance.

1 April 2014
Verified
Conference Paper
Closed access
AIAnuar Idris
Anuar Idris
RBRahimi Baharom
Rahimi Baharom
NHNgah Ramzi Hamzah
Ngah Ramzi Hamzah
MHMustafar Kamal Hamzah
Mustafar Kamal Hamzah
In this paper, a computer simulation model of Hysteresis Current Control (HCC) technique for AC to DC converter fed permanent magnet DC motor (PMDC) using single-phase matrix converter (SPMC) topology is investigated. As the AC-DC converter fed PMDC motor yields a non-linear load, this can affect the generating of harmonics resulting high total harmonics distortion (THD) level hence low power factor. In addition, this phenomenon also have a set back in deteriorating the system operating performances. The use of HCC to achieve high power factor and low total harmonic distortion (THD) level is proposed. On the basis of the proposed modelling, the switching algorithm of the hysteresis control for the active power filter function (APF) is firstly studied and investigated. Simulation results are presented to verify the accuracy and feasibility of the proposed solution.

12 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
MRMUHAMMAD SHAWWAL BIN MOHAMAD RAWI
MUHAMMAD SHAWWAL BIN MOHAMAD RAWI
RBRahimi Baharom
Rahimi Baharom
MRMohd Amran Mohd Radzi
Mohd Amran Mohd Radzi
This study introduces a novel uninterruptible power supply (UPS) configuration that integrates active power filter (APF) capabilities within a single-phase matrix converter (SPMC) framework. Power disruptions, particularly affecting critical loads, can lead to substantial economic damages. Historically, conventional UPS systems utilized dual separate converters to function as a rectifier and an inverter, without incorporating any power factor correction (PFC) mechanisms. Such configurations suffered from diminished power density, compromised reliability, and spatial limitations. To address these issues, this research proposes an enhanced UPS design that incorporates APF features into the SPMC. The focus of this investigation is on the efficiency of alternating current (AC) to direct current (DC) conversion and the reverse process utilizing this advanced UPS model. The SPMC is selected to supplant the rectifier and inverter units traditionally employed in UPS architectures. A novel integrated switching strategy is formulated to facilitate the operation of the UPS in either rectifier (charging) or inverter (discharging) modes, contingent upon the operational state. The performance and efficacy of the devised circuit design and switching technique are substantiated through simulations conducted in MATLAB/Simulink 2019 and empirical evaluations using a test rig. The findings demonstrate that the voltage generated is sinusoidal and synchronized with the supply current, thereby minimizing the total harmonic distortion (THD) and enhancing both the power factor and the transition efficiency of the UPS system between its charging and discharging states.

1 June 2022 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
MRMuhammad Shawwal Mohamad Rawi
Muhammad Shawwal Mohamad Rawi
RBRahimi Baharom
Rahimi Baharom
NANur Hidayah Abdullah
Nur Hidayah Abdullah
This paper presents a computer simulation model of the unity power factor uninterruptible power supply (UPS) topology using single-phase matrix converter (SPMC) that focuses on the switching integration for both rectifier and inverter operations. The proposed integrated switches capable of controlling the SPMC to operate as a rectifier operation to charge the DC battery during the normal operation and to switch the SPMC to operate as an inverter during power outage conditions continuously and instantaneously using a single power converter circuit. The use of a single power converter circuit can solve the typical UPS system that requires at least two separate power converter circuits, thus contributing to the higher power semiconductor losses and complicated control circuits. With the proposed circuit topology, it can improve the power density of the power electronics converter system resulting in low power losses. The active power filter (APF) function has been used to improve the supply current waveform to follow the shape of the sinusoidal reference current to be in phase with the supply voltage waveform, thus reduce the total harmonic distortion (THD) level and improve the power factor. To verify the proposed operation, the selected simulation results are presented, and the proposed work has been done through the MATLAB/Simulink.

1 September 2019 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
DODygku Aniqnatasa Awg Osman
Dygku Aniqnatasa Awg Osman
RBRahimi Baharom
Rahimi Baharom
DJDalina Johari
Dalina Johari
MHMuhamad Nabil Hidayat
Muhamad Nabil Hidayat
KMKhairul Safuan Muhammad
Khairul Safuan Muhammad
The development of active power filter (APF) using rectifier boost technique has been identified to compensate for the pulsating nature of the distorted supply current waveform of non-linear load. In this work, investigation is carried out on the operation of rectifier without any filters function. This is then extended to operate the rectifier converter with an active power filter function. APF function is implemented by enabling the closed-loop control using standard proportional integral control to rectify the distorted supply current to become continuous, sinusoidal and in-phase with the supply voltage waveform. Consequently, the total harmonic distortion (THD) level was reduced to meet the acceptable limit defined in the standard of IEEE-519 1992. The selected simulation results obtained from MATLAB/Simulink are presented to justify the proposed filter structure.

1 September 2020 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
RBRahimi Baharom
Rahimi Baharom
IYIhsan Mohd Yassin
Ihsan Mohd Yassin
NHNabil M. Hidayat
Nabil M. Hidayat
This paper presents the Hysteresis Current Control (HCC) to improve the power quality of power electronic converters. The development of HCC was implemented using Active Power Filter (APF) function based on rectifier boost technique to control the range of upper and lower bands. Through this technique, the supply current waveform followed the shape of the sinusoidal reference signal, thus, the distorted input current waveform becomes sinusoidal and in the same phase with the input voltage. As a result, the THD level and switching losses can be reduced, thus improving the power factor of the power supply system. In order to verify the proposed operation, validation of the proposed HCC was done through MATLAB. Selected simulation results are presented.