For nearly 20 years, the Test Feeder Working Group of the Distribution System Analysis Subcommittee has been developing openly available distribution test feeders for use by researchers. The purpose of these test feeders is to provide models of distribution systems that reflect the wide diversity in design and their various analytic challenges. Because of their utility and accessibility, the test feeders have been used for a wide range of research, some of which has been outside the original scope of intended uses. This paper provides an overview of the existing distribution feeder models and clarifies the specific analytic challenges that they were originally designed to examine. Additionally, this paper will provide guidance on which feeders are best suited for various types of analysis. The purpose of this paper is to provide the original intent of the Working Group and to provide the information necessary so that researchers may make an informed decision on which of the test feeders are most appropriate for their work.
28 October 2008 in IEEE Transactions on Power Systems
Vulnerability assessment is a requirement of NERC's cybersecurity standards for electric power systems. The purpose is to study the impact of a cyber attack on supervisory control and data acquisition (SCADA) systems. Compliance of the requirement to meet the standard has become increasingly challenging as the system becomes more dispersed in wide areas. Interdependencies between computer communication system and the physical infrastructure also become more complex as information technologies are further integrated into devices and networks. This paper proposes a vulnerability assessment framework to systematically evaluate the vulnerabilities of SCADA systems at three levels: system, scenarios, and accesspoints. The proposed method is based on cyber systems embedded with the firewall and password models, the primary mode of protection in the power industry today. The impact of a potential electronic intrusion is evaluated by its potential loss of load in the power system. This capability is enabled by integration of a logic-based simulation method and a module for the power flow computation. The IEEE 30-bus system is used to evaluate the impact of attacks launched from outside or from within the substation networks. Countermeasures are identified for improvement of the cybersecurity.
3 June 2010 in IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans
Disruption of electric power operations can be catastrophic on national security and the economy. Due to the complexity of widely dispersed assets and the interdependences among computer, communication, and power infrastructures, the requirement to meet security and quality compliance on operations is a challenging issue. In recent years, the North American Electric Reliability Corporation (NERC) established a cybersecurity standard that requires utilities' compliance on cybersecurity of control systems. This standard identifies several cyber-related vulnerabilities that exist in control systems and recommends several remedial actions (e.g., best practices). In this paper, a comprehensive survey on cybersecurity of critical infrastructures is reported. A supervisory control and data acquisition security framework with the following four major components is proposed: (1) real-time monitoring; (2) anomaly detection; (3) impact analysis; and (4) mitigation strategies. In addition, an attack-tree-based methodology for impact analysis is developed. The attack-tree formulation based on power system control networks is used to evaluate system-, scenario -, and leaf-level vulnerabilities by identifying the system's adversary objectives. The leaf vulnerability is fundamental to the methodology that involves port auditing or password strength evaluation. The measure of vulnerabilities in the power system control framework is determined based on existing cybersecurity conditions, and then, the vulnerability indices are evaluated.
Cybersecurity of the substations in a power system is a major issue as the substations become increasingly dependent on computer and communication networks. This paper is concerned with anomaly detection in the computer network environment of a substation. An anomaly inference algorithm is proposed for early detection of cyber-intrusions at the substations. The potential scenario of simultaneous intrusions launched over multiple substations is considered. The proposed detection method considers temporal anomalies. Potential intrusion events are ranked based on the credibility impact on the power system. Snapshots of anomaly entities at substations are described. Simulation results using the modified IEEE 118-bus system have shown the effectiveness of the proposed method for systematic identification. The result of this research is a tool to detect cyber-intrusions that are likely to cause significant damages to the power grid.
16 February 2015 in IEEE Transactions on Smart Grid
As information and communication networks are highly interconnected with the power grid, cyber security of the supervisory control and data acquisition (SCADA) system has become a critical issue in the electric power sector. By exploiting the vulnerabilities in cyber components and intruding into the local area networks of the control center, corporation, substations, or by injecting false information into communication links, the attackers are able to eavesdrop critical data, reconfigure devices, and send trip commands to the intelligent electronic devices that control the system breakers. Reliability of the power system can thus be impacted by various cyber attacks. In this paper, four attack scenarios for cyber components in networks of the SCADA system are considered, which may trip breakers of physical components. Two Bayesian attack graph models are built to illustrate the attack procedures and to evaluate the probabilities of successful cyber attacks. A mean time-to-compromise model is modified and adopted considering the known and zero-day vulnerabilities on the cyber components, and the frequencies of intrusions through various paths are estimated. With increased breaker trips resulting from the cyber attacks, the loss of load probabilities in the IEEE reliability test system 79 are estimated. The simulation results demonstrate that the power system becomes less reliable as the frequency of successful attacks on the cyber components increases and the skill levels of attackers increase.
28 October 2008 in IEEE Transactions on Power Systems
This paper proposes an extensive fault location model for underground power cable in distribution system using voltage and current measurements at the sending-end. First, an equivalent circuit that models a faulted underground cable system is analyzed using distributed parameter approach. Then, the analysis of sequence networks in three-phase network is obtained by applying the boundary conditions. This analysis is used to calculate a fault distance in single section using voltage and current equations. The extension to multi-section is further analyzed based on Korean distribution systems. This method is an iterative process to determine a faulted section from the network. Finally, the case studies are evaluated with variations of fault distance and resistance, which also includes the evaluation of its robustness to load uncertainty.