Currently, hip braces are recommended and typically worn by femoroacetabular impingement (FAI) patients after hip arthroscopic surgery. However, there is currently a lack of literature regarding the biomechanical effectiveness of hip braces. The purpose of this study was to investigate the biomechanical effect of hip braces after hip arthroscopic surgery for FAI. Overall, 11 patients who underwent arthroscopic FAI correction and labral preservation surgery were included in the study. Standing-up and walking tasks in unbraced and braced conditions were performed at 3 weeks postoperatively. For the standing-up task, videotaped images of the hip’s sagittal plane were recorded while patients stood from a seated position. After each motion, the hip flexion-extension angle was calculated. For the walking task, acceleration of the greater trochanter was measured using a triaxial accelerometer. For the standing-up motion, the mean peak hip flexion angle was found to be significantly lower in the braced condition than in the unbraced condition. Furthermore, the mean peak acceleration of the greater trochanter was significantly lower in the braced condition than in the unbraced condition. Patients undergoing arthroscopic FAI correction surgery would benefit from usage of a hip brace in terms of protecting repaired tissues during early postoperative recovery.
17 February 2026 in Prosthetics and Orthotics International
Background: Spinal bracing remains the gold standard for conservative management of adolescent idiopathic scoliosis (AIS). However, poor adherence often limits treatment efficacy. The development of a brace that enhances compliance while maintaining sufficient corrective force is crucial. Objectives: This study aimed to develop and evaluate the effectiveness of a novel semi-rigid brace for AIS based on wearing time and correction rate. Study design: Multicenter prospective observational study. Methods: We enrolled patients who met the following Scoliosis Research Society criteria for brace treatment: (1) confirmed AIS diagnosis, (2) Risser sign ≤2, (3) Cobb angle between 25° and 40°, (4) age ≥10 years, and (5) single-curve pattern. Wearing time was objectively measured over 180 d using embedded temperature sensors. Correction rates were assessed at initiation and after 12 months or more. Results: A total of 60 patients with AIS were included. Among them, 24 had thoracic curves, and 36 had thoracolumbar/lumbar curves. The mean daily wearing time was 16.3 h for thoracic curves and 18.2 h for thoracolumbar/lumbar curves. The median initial correction rate was 32% for thoracic curves and 45% for thoracolumbar/lumbar curves. After 12 months or more, the median correction rate was 20% and 48%, respectively. The dropout rate was 5%, and no severe skin complications were observed. Conclusions: The novel semi-rigid brace demonstrated high compliance and effective curve correction over 12 months. These findings support its potential as a comfortable and effective conservative treatment option for patients with AIS.