Extracellular cues stimulate the Abl family nonreceptor tyrosine kinase Arg to promote actin-based cell edge protrusions. Several Arg-interacting proteins are potential links to the actin cytoskeleton, but exactly how Arg stimulates actin polymerization and cellular protrusion has not yet been fully elucidated. We used affinity purification to identify N-WASp as a novel binding partner of Arg. N-WASp activates the Arp2/3 complex and is an effector of Abl. We find that the Arg SH3 domain binds directly to N-WASp. Arg phosphorylates N-WASp on Y256, modestly increasing the affinity of Arg for N-WASp, an interaction that does not require the Arg SH2 domain. The Arg SH3 domain stimulates N-WASp-dependent actin polymerization in vitro, and Arg phosphorylation of N-WASp weakly stimulates this effect. Arg and N-WASp colocalize to adhesion-dependent cell edge protrusions in vivo. The cell edge protrusion defects of arg−/− fibroblasts can be complemented by re-expression of an Arg-yellow fluorescent protein (YFP) fusion, but not by an N-WASp binding-deficient Arg SH3 domain point mutant. These results suggest that Arg promotes actin-based protrusions in response to extracellular stimuli through phosphorylation of and physical interactions with N-WASp.
Calcifications associated with ductal carcinoma in situ (DCIS) are more extensive at diagnosis and grow faster than those associated with benign breast disease. BackgroundMost ductal carcinoma in situ (DCIS) lesions are first detected on screening mammograms as calcifications. However, false-positive biopsy rates for calcifications range from 30% to 87%. I...
We sought to develop new quantitative approaches to characterize the spatial distribution of mammographic density and contrast enhancement of suspicious contrast-enhanced mammography (CEM) findings to improve malignant vs. benign classifications of breast lesions. We retrospectively analyzed all breast lesions that underwent CEM imaging and tissue sampling at our institution from 2014–2020 in this IRB-approved study. A penalized linear discriminant analysis was used to classify lesions based on the averaged histograms of radial distributions of mammographic density and contrast enhancement. T-tests were used to compare the classification accuracies of density, contrast, and concatenated density and contrast histograms. Logistic regression and AUC-ROC analyses were used to assess if adding demographic and clinical data improved the model accuracy. A total of 159 suspicious findings were evaluated. Density histograms were more accurate in classifying lesions as malignant or benign than a random classifier (62.37% vs. 48%; p < 0.001), but the concatenated density and contrast histograms demonstrated a higher accuracy (71.25%; p < 0.001) than the density histograms alone. Including the demographic and clinical data in our models led to a higher AUC-ROC than concatenated density and contrast images (0.81 vs. 0.70; p < 0.001). In the classification of invasive vs. non-invasive malignancy, the concatenated density and contrast histograms demonstrated no significant improvement in accuracy over the density histograms alone (77.63% vs. 78.59%; p = 0.504). Our findings suggest that quantitative differences in the radial distribution of mammographic density could be used to discriminate malignant from benign breast findings; however, classification accuracy was significantly improved with the addition of contrast-enhanced imaging data from CEM. Adding patient demographic and clinical information further improved the classification accuracy.