Andrea Cirillo

Mr. Andrea Cirillo


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2021 in The European Physical Journal Plus
Verified
Journal Article
Open access
PDF file
ACAndrea Cirillo
Andrea Cirillo
RMRuggero Meucci
Ruggero Meucci
MCMichele Caresana
Michele Caresana
MCMarco Caresana
Marco Caresana
Soil moisture is a crucial variable in evaluating soil properties and its interaction with the atmosphere, yet none of the techniques currently employed is fully adequate for evaluating the water content in soil over an area of hectares and depth of tens of centimeters. In recent times, it has been shown how the water content over this volume can be accurately assessed measuring changes in the epithermal flux of cosmic neutrons, which is extremely sensitive to the moderation caused by hydrogen. The instruments employed for neutron flux measurements are usually neutron counters, covered with moderator coatings for enhancing their sensitivity in the epithermal energy range. On the other hand, the worldwide shortage of $${}^{3}$$ 3 He caused a considerable increase in the costs associated with the manufacturing of proportional counters based on this gas, which were widely employed for their great sensitivity and noise rejection capability. In this work, we developed a $${}^{3}$$ 3 He-free neutron spectrometer for performing these measurements, which detects neutrons in the energy range from 0.01 ev to 1 GeV. The reconstruction of the energy spectrum allows a more accurate evaluation of the epithermal neutron flux and provides other information which improves the quality of soil moisture measurements. Irradiations performed with neutron sources of $${}^{241}$$ 241 Am and AmBe allowed to evaluate the spectrometric capability of the instrument, whereas the measurements of cosmic neutrons were employed to assess its sensitivity to cosmic radiation. The sensitivity of the instrument is slightly less than the one of the neutron counters currently employed, yet the access to the spectrometric information should provide greater accuracy in the epithermal flux measurements.

4 April 2025 in Medical Physics
Verified
Journal Article
Open access
MBMatteo Bolzonella
Matteo Bolzonella
MCMarco Caresana
Marco Caresana
ACAndrea Cirillo
Andrea Cirillo
JMJosep M. Martí‐Climent
Josep M. Martí‐Climent
EMEvangelina Martínez‐Francés
Evangelina Martínez‐Francés
JVJosé Vedelago
José Vedelago
Background: In hadron therapy, out‐of‐field doses, which may in the long‐term cause secondary cancers, are mostly due to neutrons. Very recently, 4 He and 16 O beams have been added to protons and 12 C ions for clinical therapy. Purpose: The focus of this article is to compare secondary neutron doses produced by clinical protons, 4 He, 12 C, and 16 O ion beams. Methods: Ambient dose equivalent, H *(10), measurements were performed, with five types of rem counters, of the neutron field produced by the four primary ions impinging on a water phantom. This experiment was performed at the Heidelberg Ion Beam Therapy Center (HIT) in the framework of the activities of the European Radiation Dosimetry Group (EURADOS). The experimental data are normalized to both unit primary particle and target dose, and are further compared to Monte Carlo (MC) simulations performed with the FLUKA and MCNP codes. Results: The intensity of the neutron field increases with ion mass, and the trend is more significant in the forward direction. The minimum H *(10) for all ions, 5µSv/Gy to 10µSv/Gy, was measured in the transverse and backward directions, whereas the maximum measured value was about 1.3 mSv/Gy for primary 16 O ions in the forward direction. Additional MC simulations are presented for a more detailed analysis of the rem counters’ response in the presence of heavy charged fragments. In the downstream direction, for 12 C and 16 O ions, approximately only 30% of the instruments’ counts are due to neutrons. Conclusion: The four extended‐range instruments provide reliable and consistent results, whereas the conventional rem counter underestimates H *(10) in a neutron field with a large high‐energy component. FLUKA and MCNP provide consistent predictions, within a factor of 1.6 for the downstream position and lower differences in the other cases, and are in agreement with the experimental data. It was found that under certain conditions neutrons do not represent the only secondary radiation field to be monitored; the presence of charged particles affects the performance of moderator‐type neutron detectors.

24 August 2023 in The European Physical Journal Plus
Verified
Journal Article
Open access
PDF file
ACAndrea Cirillo
Andrea Cirillo
MCMarco Caresana
Marco Caresana
The LUPIN is a Rem counter for neutron dosimetry in pulsed radiation fields, i.e., those fields whose intensity varies greatly on short timescales with respect to the characteristic time of the utilized detector. This work describes the characterization of the energy response of the instrument. The response function was calculated with the Monte Carlo code MCNP6, representing the geometry and material composition of the LUPIN and simulating an irradiation in expanded and aligned monoenergetic neutron fields. The calculated response was validated in the monoenergetic fields of the National Physical Laboratory. The agreement between the calculated and measured responses is satisfactory, with a maximum discrepancy of 5%.

11 October 2023 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
MCMarco Caresana
Marco Caresana
ACAndrea Cirillo
Andrea Cirillo
MBMatteo Bolzonella
Matteo Bolzonella
Dosimetry in pulsed and mixed radiation fields represents an important challenge in radiation measurements, because in several accelerator technologies, the acceleration occurs in bunches of particles with short time duration, producing intense radiation pulses spaced by a relatively long time of beam off. The stray mixed radiation field generated around these installations maintains the same time structure as the primary beam and causes a problem in workplace fields’ monitoring. Active neutron detectors normally used in steady neutron fields, specifically REM-counters and Bonner sphere spectrometers, can suffer pulsed fields because of the high dead time losses during the bursts and are often inadequate for pulsed field monitoring. This work reviews the efforts of European Radiation Dosimetry Group (EURADOS), and in particular of the Working Group 11 ‘High Energy Radiation Fields’, to define the problem, characterize instrumentation and to propose solutions to the issue of pulsed and mixed radiation fields. Despite the EURADOS initiative, several open issues still remain. A metrological traceability for pulsed neutron fields is missing. There is still room for the optimization and better characterization of available instruments. Initiatives of education and training are required.

6 July 2022 in The European Physical Journal Plus
Verified
Journal Article
Open access
PDF file
ACAndrea Cirillo
Andrea Cirillo
MCMarco Caresana
Marco Caresana
Over the last year, Politecnico di Milano has developed the W-PIE, a cosmic neutron spectrometer employed for environmental measurements. The W-PIE is based on the Artkis M800 thermal neutron detector and works as a 4-channel spectrometer for detecting neutrons in the energy range 0.01eV – 1GeV. In this paper, the calibration of the instrument in monoenergetic neutron fields at the PIAF facility of PTB is discussed. These measurements were intended to calibrate the detector and validate the response functions. Despite obtaining satisfactory results in terms of fluence and dose calculations, the irradiation in the monoenergetic fields suggested that the detector sensitivity to fast neutrons was greater than expected by the calculated response functions. This discrepancy was investigated and a reasonable explanation for it was proposed.

11 October 2023 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
ACAndrea Cirillo
Andrea Cirillo
MCMarco Caresana
Marco Caresana
The W-PIE is a cosmic neutron spectrometer used for environmental measurements, developed by Politecnico di Milano. The instrument is based on the Artkis M800 thermal neutron detector and works as a 4-channel spectrometer for detecting neutrons in the energy range of 0.01 eV–1 GeV. After the spectrometer had been calibrated in some monoenergetic neutron fields at the PIAF facility of PTB, the instrument was tested in the neutron field generated at the CERF facility, whose spectrum fairly resembles the cosmic one. This measurement is a precious tool for predicting the performance of the instrument in a realistic situation.