This report describes a clinical and laboratory protocol used in the fabrication of a removable partial dental prosthesis with a digital workflow in a 73-year-old patient. The metal framework was produced with a selective laser melting technique. For quality assurance and discrepancy analysis, the framework was superimposed and compared to the respective digital design file, and the printed model was also compared to the digital impression and rendered as a 3D colour map. Differences were detected in the framework on the clasp of tooth 17 (upper right second molar) and on the printed model on the interproximal surfaces of the abutments, particularly on tooth 17 and palatine area. The use of this digital workflow allowed for the achievement of an removable partial dental prosthesis with a good fit and occlusion with minimal adjustments, with the reduction of both clinical and laboratory time. Further studies are needed to gain a better understanding of these techniques.
8 June 2021 in Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial
The selective laser melting technology is an additive digital method that permits producing metal frameworks for removable partial dentures. The existing literature has compared this technique with the classic technique in terms of precision, quality of fit, and function. This work describes a clinical case of a metal framework produced by the selective laser melting technique in a patient rehabilitated with a removable partial denture. No adjustments were required when the metal framework was inserted, showing good adaptation and stability to the abutment teeth and surrounding tissues. Further studies are necessary for a significant assessment of this technique’s clinical applicability.
Titanium is the most commonly used material to manufacture dental implants and abutments. Recently, zirconia abutments have been manufactured with better aesthetic properties. However, zirconia abutments are harder than titanium implants; therefore, they could wear the implant surface. Therefore, this article aims to describe a sphere-plane system that can be used to assess the wear that different abutment materials cause in the titanium of dental implants when submitted to cyclic loading. This method can be used to simulate the oral cavity, where the abutment (sphere) applies loads onto the implant (titanium plane). The spheres were made of different materials (titanium and zirconia), and the specimens were loaded for 4,000,000 cycles. The scar size and area on titanium planes were measured with stereoscopic images and analysed through profilometry. The wear of titanium planes was similar when tested against zirconia or titanium spheres. The sphere-plane system is a method that can be used to evaluate and quantify the wear of the titanium of dental implants, and compared with methods that use real implants, this system is simpler and less expensive. This method could facilitate further research to evaluate the wear of titanium against different materials and under different testing conditions.
The most commonly used material in dental implants and their abutments is titanium. Zirconia is a more aesthetic alternative to titanium abutments; however, it is much harder. There are concerns that zirconia could damage the surface of the implant over time, especially in less stable connections. The aim was to evaluate the wear of implants with different platforms connected to titanium and zirconia abutments. A total of six implants were evaluated, two of each connection type: external hexagon, tri-channel, and conical connections (n = 2). Half of the implants were connected to zirconia abutments, and the other half to titanium abutments (n = 3). The implants were then cyclically loaded. The implant platforms were evaluated by digital superimposing micro CT files and calculating the area of the loss surface (wear). In all the implants, a statistically significant loss of the surface area (p = 0.028) was observed when comparing the area before and after cyclic loading. The average lost surface area was 0.38 mm2 with titanium abutments and 0.41 mm2 with zirconia abutments. The average lost surface area was 0.41 mm2 with the external hexagon, 0.38 mm2 with the tri-channel, and 0.40 mm2 with the conical connection. In conclusion, the cyclic loads induced implant wear. However, neither the type of abutment (p = 0.700) nor the connection (p = 0.718) influenced the amount of surface area lost.
4 October 2022 in Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial
Objectives: To evaluate the effects of the abutment material and the connection type on the implant-abutment connection rigidity. Methods: The study evaluated eighteen implants with three different types of connections: external-hexagon, tri-channel, and conical connection. Half of the implants were connected to titanium abutments, and the other half to zirconia abutments, forming six study groups (n=3). The implants were submitted to 1,200,000 load cycles with a force amplitude of 90 N. During load application, the implant-abutment connection rigidity was determined in each cycle. The values obtained were analyzed with the two-way ANOVA test according to the abutment and connection types. Results: Rigidity tended to increase during loading cycles. The abutment material did not influence rigidity (p=0.883). The external-hexagon connection presented lower rigidity than the internal connections, with statistically significant differences (p=0.013). Conclusions: The abutment material does not influence the implant-abutment connection’s rigidity. The external-hexagon connection proved to be less rigid and stable than the internal connections.
30 December 2023 in Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial
Objectives: To evaluate the communication between dentists and dental technicians in Lisbon for the construction of metal frameworks for removable partial dentures (R...