The Greenhouse gases Monitoring Instrument on GaoFen-5 satellite-II (GMI-II) uses spatial heterodyne spectroscopy (SHS) for quantitative monitoring of atmospheric greenhouse gases (GHG). Unlike the traditional SHS, the interferometer component of the GMI-II was designed with zero optical path difference offset, effectively improving spectral resolution while maintaining the same detector specifications. The secondary imaging system with non-isometric scaling of spatial and spectral dimensions was designed to decrease the integration time of a frame image or improve the spectral signal-to-noise ratio (SNR) under the same integration time. This paper introduces the design, manufacture, adjustment methods, and test results of the main performance indexes of the GMI-II that indicate that the spectral resolution of the O2 A-band detection channel is better than 0.6 cm−1 and other channels are better than 0.27 cm−1. Under the typical radiance of other carbon monitors’ on-orbit statistics, the spectral SNR of the GMI-II is more than 300. These test results demonstrate that the GMI-II can be well adapted to quantitative remote sensing monitoring of atmospheric GHG.
Considering the distribution characteristics of interference data of a temporally and spatially modulated spatial heterodyne interference imaging spectrometer, an algorithm based on spatial dimension baseline of interference data for the detection and correction of invalid data is proposed. The intensity ratio of the target interference data far away from the zero optical path difference has been extracted and calculated, and the intensity of the interference data is compensated; the baseline of the compensated interference data is carried out along the spatial dimension direction, and the deviation matrix is calculated, and combined with the method for the detection and correction of invalid data. A simulation experiment is carried out in the laboratory to obtain the target push-sweep imaging interference data, and the spectrum is the output spectrum of the integrating sphere halogen tungsten lamp. The experimental results show that the invalid data in the interference data (including invalid data near zero optical path difference) can be effectively identified and corrected using the invalid data detection and correction algorithm described in this paper, which has a good effect on the correction of fixed invalid data and flash pixel.
The Greenhouse Gas Monitoring Instrument (GMI), carried by Gaofen 5 (GF5-01), and the Hyperspectral Observation Satellite (GF5-02) were successfully launched on 9 May 2018, and September 7, 2021, respectively, and are the only passive greenhouse gas payloads in China that can regularly obtain effective detection data in-orbit at this stage. Before launch, the research team carried out much laboratory calibration work and designed an on-board calibration system based on solar radiation sources which guarantees the quantitative accuracy of the payload data to the greatest extent. In order to more effectively meet the high frequency calibration requirements over the whole life cycle of the payload, the research team carried out research using the on-track site calibration method based on digital calibration field network technology, and the obtained calibration coefficient effectively complements the laboratory and on-board calibration results. The working principle of the GMI is quite different from that of a traditional imaging payload. Spatial heterodyne spectroscopy (SHS) is used to detect the absorption spectrum of greenhouse gases, has a large field of view and is non-imaging and hyperspectral. The existing fixed-site alternative calibration methods cannot fully meet the requirements of calibration tasks. In this paper, we propose a set of global digital calibration radiation field screening criteria that can meet the characteristics of the GMI and design a method to calculate the site calibration coefficients of non-absorption spectral channels according to the characteristics of hyperspectral data. Based on the historical observation data of the GMI, the initial calibration calculation of the payload launch was carried out, and the calibration results of four spectral channels of the GMI were obtained: The calibration coefficient range of the O2 channel is 1.05–1.15, the mean value is 1.10 and the standard deviation is 2.72%; the calibration coefficient of the CO2-1 channel is 1.05–1.13, the mean value is 1.09 and the standard deviation is 2.64%; the calibration coefficient of the CH4 channel is 1.08–1.10, the mean value is 1.11 and the standard deviation is 2.73%; the calibration coefficient of the CO2-2 channel is 1.09–1.14, the mean value is 1.12 and the standard deviation is 2.93%. The above results show that the radiation performance of each channel of the GMI shows no significant attenuation during this period, that the site calibration coefficient has no significant fluctuation and that the in-orbit operation state is stable.
Interference data obtained by a spatial heterodyne spectrometer (SHS) is subject to various error factors and suffers from complex phase distortion. Traditional phase correction methods, such as the Amplitude, Merzt, and Forman methods, extract phase distortion in the spectral domain and correct it, which cannot effectively correct spatial phase distortion. Through theoretical derivation and numerical simulation, the spatial phase distortion is firstly determined and corrected in the interference domain. The frequency-dependent phase distortion is then extracted in the spectral domain and corrected. This novel phase distortion correction method named the phase decomposition method was applied to the in-orbit interference data of Greenhouse gases Monitoring Instrument-II (GMI-II). Compared with traditional phase correction methods, the root-mean-square error of the spectrum corrected using the phase decomposition method is reduced by 81.37%.
The wafer eccentricity deviation caused by misalignment between the center of the wafer and rotary table will lead to edge image distortion and quality degradation of the defect signals during automated inspection. However, wafer end jump and edge topography change will bring great challenges to the accurate measurement of micrometer deviations. A new wafer eccentricity deviation measurement method based on line-scanning chromatic confocal sensors (LSCCSs) is proposed. Firstly, the LSCCS with Z-axis submicron resolution used in the experiment acquires the 3D profile height of the wafer edge as the turntable rotates, and the edge distance is calculated at each rotation angle. Secondly, a robust Fourier-LAR fitting method is used to fit edge distance serial to reduce sensitivity to outliers. Finally, the wafer eccentricity deviation that is equal to the wafer center coordinate can be calculated using the wafer eccentricity deviation model. In the simulated experiment, the results show that the eccentricity deviation measurement accuracy was insensitivity to noise and reached the micron level. Additionally, the measurement uncertainty of eccentricity deviation coordinate was (0.53 µm, 1.4 µm) in the actual data of the 12-inch wafers.