Laura Zarnitz

Ms. Laura Zarnitz


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2022 in Antioxidants
Verified
Journal Article
Open access
PDF file
EEEileen Edgworth
Eileen Edgworth
LELisa Ernst
Lisa Ernst
Zoltan CziganyZoltan Czigany
Zoltan Czigany
Turgay SaritasTurgay Saritas
Turgay Saritas
LZLaura Zarnitz
Laura Zarnitz
Christian BleilevensChristian Bleilevens
Christian Bleilevens
Normothermic machine perfusion (NMP) of kidneys in combination with an optimized perfusate composition may increase donor organ preservation quality, especially in the case of marginal donor grafts. Optimization of currently employed perfusates is still a subject of present research. Due to the advantages of being cell-free, easy to store, and having minimal antigenicity, hemoglobin-based oxygen carriers, such as HBOC-301 (Oxyglobin®, Hemoglobin Oxygen Therapeutics LLC, Souderton, PA, USA), offer an alternative to the commonly used perfusates based on packed red blood cells (pRBC). As previously described, using HBOC results in formation of methemoglobin (metHb) as an adverse effect, inducing hypoxic conditions during the perfusion. As a potential counterpart to metHb formation, the application of the antioxidant ascorbic acid (VitC) is of high interest. Therefore, this study was conducted in four experimental groups, to compare the effect of NMP with (1) HBOC or (3) pRBC, and additionally examine a beneficial effect of VitC in both groups (2) HBOC + VitC and (4) pRBC + VitC. All groups were subjected to NMP for 6 h at a pressure of 75 mmHg. Kidneys in the HBOC groups had a significantly lower renal blood flow and increasing intrarenal resistance, with reduced renal function in comparison to the pRBC groups, as demonstrated by significantly lower creatinine clearance and higher fractional sodium excretion rates. Clinical chemistry markers for tissue damage (LDH, lactate) were higher in the HBOC groups, whereas no significant histological differences were observed. Although the application of VitC decreased oxidative stress levels, it was not able to significantly increase the outcome parameters mentioned above in either group. This study demonstrated that HBOC-301 is inferior to pRBCs in our porcine kidney NMP model, independent of additional VitC administration. Oxidative stress and fragmentation of the hemoglobin polymers could be detected as a possible reason for these results, hence further research, focusing on the use of cell-free oxygen carriers that do not exhibit this complex of issues, is required.

21 March 2023 in Antioxidants
Verified
Journal Article
Open access
PDF file
LZLaura Zarnitz
Laura Zarnitz
BDbm doorschodt
bm doorschodt
LELisa Ernst
Lisa Ernst
AHAisa Hosseinnejad
Aisa Hosseinnejad
EEEileen Edgworth
Eileen Edgworth
Christian BleilevensChristian Bleilevens
Christian Bleilevens
Donor organ-shortage has resulted in the increased use of marginal grafts; however, normothermic machine perfusion (NMP) holds the potential for organ viability assessment and restoration of marginal grafts prior to transplantation. Additionally, cell-, oxygen carrier-free and antioxidants-supplemented solutions could potentially prevent adverse effects (transfusion reactions, inflammation, hemolysis), associated with the use of autologous packed red blood cell (pRBC)-based perfusates. This study compared 6 h NMP of porcine kidneys, using an established pRBC-based perfusate (pRBC, n = 7), with the novel cell- and oxygen carrier-free organ preservation solution Ecosol, containing taurine (Ecosol, n = 7). Despite the enhanced tissue edema and tubular injury in the Ecosol group, related to a suboptimal molecular mass of polyethylene glycol as colloid present in the solution, functional parameters (renal blood flow, intrarenal resistance, urinary flow, pH) and oxygenation (arterial pO2, absence of hypoxia-inducible factor 1-alpha) were similar to the pRBC group. Furthermore, taurine significantly improved the antioxidant capacity in the Ecosol group, reflected in decreased lactate dehydrogenase, urine protein and tubular vacuolization compared to pRBC. This study demonstrates the feasibility of 6 h NMP using a taurine containing, cell- and oxygen carrier-free perfusate, achieving a comparable organ quality to pRBC perfused porcine kidneys.

17 March 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HKHannah Katharina Krüger
Hannah Katharina Krüger
BDBenedict Doorschodt
Benedict Doorschodt
Zoltan CziganyZoltan Czigany
Zoltan Czigany
OBOliver Beetz
Oliver Beetz
FOFelix Oldhafer
Felix Oldhafer
Christian BleilevensChristian Bleilevens
Christian Bleilevens
Background/Objectives: The growing shortage of organs for transplantation requires optimized preservation techniques. Normothermic (NMP) and Subnormothermic Machine Perfusion (SMP) allow for the assessment of organ viability prior to transplantation and enable targeted therapeutic interventions while maintaining a metabolically active state in contrast to hypothermic settings. Methods: In this study, the synthetic perfusion solution “Omnisol” was used in a 6 h ex vivo setting with porcine kidneys (n = 6 NMP; n = 6 SMP). Perfusion parameters (arterial flow, intrarenal resistance and urinary flow), renal function (excretory and filtration performance), renal injury (cellular and circulating biomarkers) and tissue and perfusate oxygenation were assessed. Results: NMP resulted in better arterial flow and lower intrarenal resistance during the first 3 h of perfusion, while SMP surpassed NMP from 3 to 6 h. Renal injury biomarkers increased in the NMP group after 3 h, while no increase was detectable in the SMP group. Omnisol fully met the oxygen requirements of the kidneys in both groups, despite being fully synthetic. Conclusions: Both NMP and SMP offer distinct advantages for kidney preservation, and the synthetic perfusate Omnisol appears to be feasible for both methods. In this experimental setting, the data indicate that NMP of porcine kidneys was associated with favorable functional parameters during the early phase of perfusion, whereas SMP showed comparatively stable parameters at later time points. These findings should primarily be considered exploratory observations and require validation in future studies, especially for the translation into a clinical scenario using human kidneys.