Elshad Guliyev

Dr. Elshad Guliyev

Electrical Engineering and Information Technology, Technische Universität Ilmenau, Ilmenau, Thuringia, Germany
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Open access
PDF file
IRIvo W. Rangelow
Ivo W. Rangelow
AAAhmad Ahmad
Ahmad Ahmad
TITzvetan Ivanov
Tzvetan Ivanov
MKMarcus Kaestner
Marcus Kaestner
YKYana Krivoshapkina
Yana Krivoshapkina
DODeirdre L. Olynick
Deirdre L. Olynick
Single-electron devices operating at room temperature require sub-5 nm quantum dots having tunnel junctions of comparable dimensions. Further development in nanoelectronics depends on the capability to generate mesoscopic structures and interfacing these with complementary metal–oxide–semiconductor devices in a single system. The authors employ a combination of two novel methods of fabricating room temperature silicon single-electron transistors (SETs), Fowler–Nordheim scanning probe lithography (F-N SPL) with active cantilevers and cryogenic reactive ion etching followed by pattern-dependent oxidation. The F-N SPL employs a low energy electron exposure of 5–10 nm thick high-resolution molecular resist (Calixarene) resulting in single nanodigit lithographic performance [Rangelow et al., Proc. SPIE 7637, 76370V (2010)]. The followed step of pattern transfer into silicon becomes very challenging because of the extremely low resist thickness, which limits the etching depth. The authors developed a computer simulation code to simulate the reactive ion etching at cryogenic temperatures (−120 °C). In this article, the authors present the alliance of all these technologies used for the manufacturing of SETs capable to operate at room temperatures.

15 October 2014 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Closed access
MKMarcus Kaestner
Marcus Kaestner
TITzvetan Ivanov
Tzvetan Ivanov
ASAndreas Schuh
Andreas Schuh
AAAhmad Ahmad
Ahmad Ahmad
TATihomir Angelov
Tihomir Angelov
NNNikolay Nikolov
Nikolay Nikolov
Scanning probes have enabled modern nanoscience and are still the backbone of today's nanotechnology. Within the technological development of AFM systems, the cantilever evolved from a simple passive deflection element to a complex microelectromechanical system through integration of functional groups, such as piezoresistive detection sensors and bimaterial based actuators. Herein, the authors show actual trends and developments of miniaturization efforts of both types of cantilevers, passive and active. The results go toward the reduction of dimensions. For example, the authors have fabricated passive cantilever with a width of 4 μm, a length of 6 μm and thickness of 50–100 nm, showing one order of magnitude lower noise levels. By using active cantilevers, direct patterning on calixarene is demonstrated employing a direct, development-less phenomena triggered by tip emitted low energy (<50 eV) electrons. The scanning probes are not only applied for lithography, but also for imaging and probing of the surface before and immediately after scanning probe patterning. In summary, piezoresistive probes are comparable to passive probes using optical read-out. They are able to routinely obtain atomic step resolution at a low thermal noise floor. The active cantilever technology offers a compact, integrated system suited for integration into a table-top scanning probe nanolithography tool.

25 October 2018 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Closed access
PDF file
IRIvo W. Rangelow
Ivo W. Rangelow
MKMarcus Kaestner
Marcus Kaestner
TITzvetan Ivanov
Tzvetan Ivanov
AAAhmad Ahmad
Ahmad Ahmad
SLSteve Lenk
Steve Lenk
MHMathias Holz
Mathias Holz
More than 40 years after its invention, the atomic force microscopy (AFM) can be integrated with scanning electron microscope (SEM) instruments as an increasingly capable and productive characterization tool with sub-nanometer spatial resolution. The authors have designed and developed an AFM instrument capable to be integrated into any SEM or in a combination of SEM with a focused ion-beam (FIB) tool. The combination of two or more different types of techniques like SEM, energy dispersive x-ray spectroscopy, and AFM is called correlative microscopy because analytical information from the same place of the sample can be obtained and correlated. For the first time, they introduced to the SEM/FIB tool correlative nanofabrication methods like field-emission scanning probe lithography, tip-based electron beam induced deposition, and nanomachining. The combination of all these methods provides a completely new nanotechnology instrument, which should be seen as a tool for correlative nanofabrication and microscopy. Thus, it provides for the first time the capabilities of a stand-alone instrument with the capabilities of nondestructive three-dimensional tip-based metrology and nanofabrication into the combined SEM/FIB tool. In this article, the authors describe all these methods in detail and present a brief example of the results obtained. They demonstrate that the self-sensing, self-actuating cantilevers (called active cantilevers) equipped with Diamond tip are a versatile toolkit for fast imaging and emerging nanofabrication. The AFM integrated into SEM is using active cantilevers that can characterize and generate nanostructures all in situ without the need to break-vacuum or contaminate the sample.

1 November 2016 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Closed access
PDF file
AAAhmad Ahmad
Ahmad Ahmad
NNNikolay Nikolov
Nikolay Nikolov
TATihomir Angelov
Tihomir Angelov
TITzvetan Ivanov
Tzvetan Ivanov
ARAlexander Reum
Alexander Reum
MHMathias Holz
Mathias Holz
In this work, the fabrication and operation of an active parallel cantilever device integrating four self-sensing and self-actuating probes in an array is presented. The so called “Quattro” cantilever system is controlled by a multichannel field programmable gate array (FPGA) controller. The integrated cantilever devices are fabricated on the basis of a silicon-on-insulator wafer using surface micromachining and gas chopping plasma-etching processes [I. W. Rangelow, J. Vac. Sci. Technol., A 21, 1550 (2003)]. The unique design of the active cantilever probes provides both patterning and readout capabilities [Kaestner et al., J. Micro-Nanolithogr. MEMS 14, 031202 (2015)]. The thermomechanical actuation allows the individually operation of each cantilever in static and dynamic modes. This enables a simultaneous atomic force microscopy operation of all cantilevers in an array, while the piezoresistive read-out of the cantilever bending routinely ensures atomic resolution at a high imaging speed. The scanning probe lithography capabilities of the active cantilevers are based on the utilization of a Fowler–Nordheim field emission process of low-energy electrons (20–50 eV) for direct writing maskless lithography. The cantilever in the Quattro active cantilever array have a pitch of 125 μm (tip-to-tip distance), which allows an image size of 0.5 × 0.2 mm to be acquired within a single scan with 0.2 nm resolution in the vertical direction. Using parallel imaging, an effective scanning speed of 5.6 mm/s is achieved. The multichannel, scalable controller architecture allows four FPGA channels to scan and collect data simultaneously. A data buffer of 128 Mbits for a single frame of 4096 × 1024 pixels is applied. The designed data transfer system allows a packet size of 128 pixels to be transmitted within less than 10 μs, respectively. Thus, the entire image frame is transferred in less than 280 ms, which exceeds the required throughput in the practical cases like critical dimension-metrology and inspection. In this article, the authors are presenting the concept of the system, which combines imaging, metrology, and lithography capabilities with a low-cost of ownership. In this context, the authors are investigating the throughput capability, reproducibility, resolution, and positioning accuracy of the Quattro active cantilever system.

1 September 2012 in Microelectronic Engineering
Verified
Journal Article
Closed access
TMThomas Michels
Thomas Michels
EGElshad Guliyev
Elshad Guliyev
MKMichal Klukowski
Michal Klukowski
IRIvo W. Rangelow
Ivo W. Rangelow

4 October 2016 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Closed access
TATihomir Angelov
Tihomir Angelov
AAAhmad Ahmad
Ahmad Ahmad
EGElshad Guliyev
Elshad Guliyev
ARAlexander Reum
Alexander Reum
IAIvaylo Atanasov
Ivaylo Atanasov
NNNikolay Nikolov
Nikolay Nikolov
Merging two state-of-the-art surface research techniques, in particular, atomic force microscopy (AFM) and scanning electron microscopy (SEM), within a single system is providing novel capabilities like direct visual feedback and life-monitoring of tip-induced nanoscale interactions. In addition, the combination of AFM and SEM accelerates nanoscale characterization and metrology development. Here, the concept and first results of a novel AFM-integration into a high resolution scanning electron microscope and focused ion beam system for nanoscale characterization is presented. In this context, a six-axis AFM system using self-sensing thermomechanically transduced active cantilever was developed and integrated. The design of the developed AFM-integration is described and its performance is demonstrated. Results from combined examinations applying fast AFM-methods and SEM-image fusion, AFM-SEM combined metrology verification, and three dimensional-visualization are shown. Simultaneous operation of SEM and AFM provides a fast navigation combined with sub-10 nm topographic image acquisition. Metrology application scenarios of combined studies are discussed, for example of MoS2 and diverse metrological test structures.