Equine Gastric Ulcer Syndrome (EGUS) is a term that has been used since 1999, initially being used to describe all gastric mucosal disease in horses. Since this time, the identification of two distinct main disease entities of the equine gastric mucosa have been described under the umbrella of EGUS; these are Equine Squamous Gastric Disease (ESGD) and Equine Glandular Gastric Disease (EGGD). In 2015 the European College of Equine Internal Medicine (ECEIM) released a consensus statement defining these disease entities. This document highlighted the lack of evidence surrounding EGGD compared to ESGD, and identified knowledge gaps for further research to be directed. Subsequently, many studies on EGGD have been published, especially on pathophysiology, diagnosis, and treatment. This article updates current knowledge on both ESGD and EGGD as understanding has evolved since the last large-scale review.
1 July 2023 in Journal of Veterinary Internal Medicine
Background: Rebound gastric hyperacidity (RGH) secondary to hypergastrinemia has been suggested to contribute to the rapid recurrence of equine squamous gastric disease (ESGD) in horses after discontinuation of omeprazole. Hypothesis/Objectives: To evaluate changes in serum gastrin and chromogranin A (CgA) concentrations in response to medium-term (57-day) omeprazole treatment and after omeprazole discontinuation. Animals: Fourteen mature Thoroughbred racehorses in simulated race training. Methods: Horses received 2.28 g of oral omeprazole PO q24h for 57 days within a 61-day period, excluding a withholding period applied mid-protocol during which treatment was stopped as part of a concurrent study. Serum samples were collected on day 0 before omeprazole treatment, on day 1 of each week of the treatment period, and for an additional 5 weeks after discontinuation of treatment. Serum gastrin and CgA concentrations were analyzed using radioimmunoassay (RIA) and ELISA, respectively. Results: Median serum gastrin concentrations increased 2.5-fold from baseline to day 7 (P < .001) but did not increase further during the omeprazole treatment period. Median serum gastrin concentrations returned to baseline within 2 to 4 days after administration of the last dose of omeprazole. No effect of treatment or discontinuation was seen in serum CgA concentrations. Conclusions and Clinical Importance: Serum gastrin concentrations increased in response to omeprazole treatment but returned to baseline within 2 to 4 days after the last dose of omeprazole. No effect of treatment or discontinuation was seen in serum CgA concentrations. Our results do not support the use of tapering protocols in horses.
Gastrin is an important hormone involved in gastric acid secretion. Despite its importance, validated methods other than radioimmunoassay (RIA) to assess serum gastrin concentrations in horses are lacking. This study aims to determine the agreement between ELISA and RIA in quantifying equine serum gastrin concentrations. Serum gastrin concentrations were quantified using two ELISA kits and RIA. Samples (196) from 14 horses at different time points were analyzed using one ELISA kit and RIA, selected samples (7) were analyzed using a second ELISA kit, and the correlation between methods was calculated. The level of agreement was analyzed by Bland-Altman analysis and differences between ELISA and RIA were plotted against averages for each sample. The Pearson correlation between gastrin concentrations measured by ELISA and the RIA was 0.27 and −0.32 for ELISA kit 1 and kit 2, respectively. Mean bias (ELISA-RIA) was 198.40 pg/mL (95% CI: −142.95–539.76) and −17.90 pg/mL (95% CI: −89.98–54.19) for ELISA kit 1 and kit 2, respectively. Measurements of horse gastrin by both ELISA methods were highly variable, with an unacceptable correlation to the reference method, RIA. Using non-validated ELISA methods to quantify horse gastrin cannot be recommended.
Viscoelastic monitoring of horse coagulation is increasing due to its advantages over traditional coagulation testing. The use of a point-of-care viscoelastic coagulation monitor (VCM Vet™) has been validated for use in horses using native whole blood (NWB) but has not been assessed using citrated whole blood (CWB), a technique that might have advantages in practicality and precision. Blood was collected from 70 horses, tested in duplicate immediately using NWB (T0), and stored at room temperature as CWB for testing in duplicate at 1 (T1) and 4 (T4) hours after venipuncture for comparison to NWB. Of these horses, 20 were classified as clinically healthy and used to determine reference intervals for CWB at 1 and 4 h post-collection. There were clinically relevant differences in all measured viscoelastic parameters of CWB compared to NWB meaning that they cannot be used interchangeably. These differences were not consistent at T1 and T4 meaning the resting time of CWB influences the results and should be kept consistent. The use of CWB in this study also resulted in more machine errors when compared to NWB resulting in measurements that might not be interpretable.