Shuai Ming

Dr. Shuai Ming


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2024 in BMC Public Health
Verified
Journal Article
Open access
PDF file
SMShuai Ming
Shuai Ming
JHJie Han
Jie Han
XYXi Yao
Xi Yao
XGXiaohong Guo
Xiaohong Guo
QGQingge Guo
Qingge Guo
BLBo Lei
Bo Lei
Background: TikTok is emerging as a vital platform for health information dissemination. Despite myopia being a global public health issue, the high-quality myopia information shared by health educators often fails to go viral. It is imperative to analyze the factors influencing video quality and popularity, especially from diverse perspectives of researchers, health educators, and audiences. Methods: TikTok myopia-related videos were retrieved using TikTok’s default comprehensive search (DCS) and most liked search (MLS) strategies. Venn diagrams were employed to illustrate the relationships and commonalities between the two strategies across four sample sizes (top 200, 150, 100, and 50). Video metadata, including details such as creator information, production properties, upload time, video duration, and viewer engagement, were collected. Video quality was assessed using the DISCERN tool. Video content covering six aspects of myopia were evaluated. The impact of search strategies, video sample sizes, production properties, and myopia content on video quality and audience engagement was analyzed through single-factor or multi-factor analysis. Results: DCS and MLS retrieval strategies, as well as varying sample sizes, resulted in differences in audience engagement for myopia videos (P < 0.039), while The DISCERN quality scores remained comparable (P > 0.221). Videos published by healthcare professionals (HCPs) and non-profit organizations (NPOs) were associated with high-quality (P ≤ 0.014) but comparatively lower popularity (P < 0.033). Videos that reported contents of risk factors, management, and outcomes showed high popularity (P < 0.018), while longer video duration (> 60s) exhibited the opposite trend (P < 0.032). Content on myopia evaluation (P ≤ 0.001) and management (P ≤ 0.022) and video duration were positively correlated with higher DISCERN quality. Conclusion: Videos created by HCPs and NPOs deserve greater attention. Rather than pursuing entertaining effects, professional educators should emphasize producing concise, and high-quality myopia content that readily resonates with the audience and has the potential to go viral on the platform.

13 August 2024 in JMIR Medical Education
Verified
Journal Article
Open access
SMShuai Ming
Shuai Ming
QGQingge Guo
Qingge Guo
WCWenjun Cheng
Wenjun Cheng
BLBo Lei
Bo Lei
Background: With the increasing application of large language models like ChatGPT in various industries, its potential in the medical domain, especially in standardized examinations, has become a focal point of research. Objective: The aim of this study is to assess the clinical performance of ChatGPT, focusing on its accuracy and reliability in the Chinese National Medical Licensing Examination (CNMLE). Methods: The CNMLE 2022 question set, consisting of 500 single-answer multiple choices questions, were reclassified into 15 medical subspecialties. Each question was tested 8 to 12 times in Chinese on the OpenAI platform from April 24 to May 15, 2023. Three key factors were considered: the version of GPT-3.5 and 4.0, the prompt’s designation of system roles tailored to medical subspecialties, and repetition for coherence. A passing accuracy threshold was established as 60%. The χ2 tests and κ values were employed to evaluate the model’s accuracy and consistency. Results: GPT-4.0 achieved a passing accuracy of 72.7%, which was significantly higher than that of GPT-3.5 (54%; P<.001). The variability rate of repeated responses from GPT-4.0 was lower than that of GPT-3.5 (9% vs 19.5%; P<.001). However, both models showed relatively good response coherence, with κ values of 0.778 and 0.610, respectively. System roles numerically increased accuracy for both GPT-4.0 (0.3%‐3.7%) and GPT-3.5 (1.3%‐4.5%), and reduced variability by 1.7% and 1.8%, respectively (P>.05). In subgroup analysis, ChatGPT achieved comparable accuracy among different question types (P>.05). GPT-4.0 surpassed the accuracy threshold in 14 of 15 subspecialties, while GPT-3.5 did so in 7 of 15 on the first response. Conclusions: GPT-4.0 passed the CNMLE and outperformed GPT-3.5 in key areas such as accuracy, consistency, and medical subspecialty expertise. Adding a system role insignificantly enhanced the model’s reliability and answer coherence. GPT-4.0 showed promising potential in medical education and clinical practice, meriting further study.

14 November 2024 in Journal of Medical Internet Research
Verified
Journal Article
Open access
SMShuai Ming
Shuai Ming
XYXi Yao
Xi Yao
XGXiaohong Guo
Xiaohong Guo
QGQingge Guo
Qingge Guo
KXKunpeng Xie
Kunpeng Xie
BLBo Lei
Bo Lei
Background: Artificial intelligence (AI) chatbots such as ChatGPT are expected to impact vision health care significantly. Their potential to optimize the consultation process and diagnostic capabilities across range of ophthalmic subspecialties have yet to be fully explored. Objective: This study aims to investigate the performance of AI chatbots in recommending ophthalmic outpatient registration and diagnosing eye diseases within clinical case profiles. Methods: This cross-sectional study used clinical cases from Chinese Standardized Resident Training–Ophthalmology (2nd Edition). For each case, 2 profiles were created: patient with history (Hx) and patient with history and examination (Hx+Ex). These profiles served as independent queries for GPT-3.5 and GPT-4.0 (accessed from March 5 to 18, 2024). Similarly, 3 ophthalmic residents were posed the same profiles in a questionnaire format. The accuracy of recommending ophthalmic subspecialty registration was primarily evaluated using Hx profiles. The accuracy of the top-ranked diagnosis and the accuracy of the diagnosis within the top 3 suggestions (do-not-miss diagnosis) were assessed using Hx+Ex profiles. The gold standard for judgment was the published, official diagnosis. Characteristics of incorrect diagnoses by ChatGPT were also analyzed. Results: A total of 208 clinical profiles from 12 ophthalmic subspecialties were analyzed (104 Hx and 104 Hx+Ex profiles). For Hx profiles, GPT-3.5, GPT-4.0, and residents showed comparable accuracy in registration suggestions (66/104, 63.5%; 81/104, 77.9%; and 72/104, 69.2%, respectively; P=.07), with ocular trauma, retinal diseases, and strabismus and amblyopia achieving the top 3 accuracies. For Hx+Ex profiles, both GPT-4.0 and residents demonstrated higher diagnostic accuracy than GPT-3.5 (62/104, 59.6% and 63/104, 60.6% vs 41/104, 39.4%; P=.003 and P=.001, respectively). Accuracy for do-not-miss diagnoses also improved (79/104, 76% and 68/104, 65.4% vs 51/104, 49%; P<.001 and P=.02, respectively). The highest diagnostic accuracies were observed in glaucoma; lens diseases; and eyelid, lacrimal, and orbital diseases. GPT-4.0 recorded fewer incorrect top-3 diagnoses (25/42, 60% vs 53/63, 84%; P=.005) and more partially correct diagnoses (21/42, 50% vs 7/63 11%; P<.001) than GPT-3.5, while GPT-3.5 had more completely incorrect (27/63, 43% vs 7/42, 17%; P=.005) and less precise diagnoses (22/63, 35% vs 5/42, 12%; P=.009). Conclusions: GPT-3.5 and GPT-4.0 showed intermediate performance in recommending ophthalmic subspecialties for registration. While GPT-3.5 underperformed, GPT-4.0 approached and numerically surpassed residents in differential diagnosis. AI chatbots show promise in facilitating ophthalmic patient registration. However, their integration into diagnostic decision-making requires more validation.

28 June 2020 in BMJ Open
Verified
Journal Article
Open access
PDF file
SMShuai Ming
Shuai Ming
KXKunpeng Xie
Kunpeng Xie
MYMingzhu Yang
Mingzhu Yang
HHHuijuan He
Huijuan He
YLYa Li
Ya Li
BLBo Lei
Bo Lei
Objective: To compare the efficacy and safety of intravitreal dexamethasone (DEX) implant and anti-vascular endothelial growth factor (anti-VEGF) agents in the treatment of macular oedema secondary to retinal vein occlusion (RVO). Design: Systematic review and meta-analysis based on Grading of Recommendations Assessment, Development and Evaluation (GRADE). Data sources: PubMed, Cochrane Library and ClinicalTrials.gov registry were searched from inception to 10 December 2019, without language restrictions. Eligibility criteria: Randomised controlled trials (RCTs) and real-world observation studies comparing the efficacy of DEX implant and anti-VEGF agents for the treatment of patients with RVO, naïve or almost naïve to both arms, were included. Data extraction and synthesis: Two reviewers independently extracted data for mean changes in best-corrected visual acuity (BCVA), central subfield thickness (CST) and product safety. Review Manager V.5.3 and GRADE were used to synthesise the data and validate the evidence, respectively. Results: Four RCTs and 12 real-world studies were included. An average lower letter gain in BCVA was determined for the DEX implant (mean difference (MD) = −6.59; 95% CI −8.87 to −4.22 letters) administered at a retreatment interval of 5–6 months. Results were similar (MD 6 months =−12.68; 95% CI −21.98 to −3.37 letters; MD 12 months =−9.69; 95% CI −12.01 to −7.37 letters) at 6 and 12 months. The DEX implant resulted in comparable or marginally less CST reduction at months 6 and 12 but introduced relatively higher risks of elevated intraocular pressure (RR=3.89; 95% CI 2.16 to 7.03) and cataract induction (RR=5.22; 95% CI 1.67 to 16.29). Most real-life studies reported an insignificant numerical gain in letters for anti-VEGF drugs relative to that for DEX implant. However, the latter achieved comparable efficacy with a 4-month dosage interval. Conclusion: Compared with anti-VEGF agents, DEX implant required fewer injections but had inferior functional efficacy and safety. Real-life trials supplemented the efficacy data for DEX implant.

8 July 2022 in Cells
Verified
Journal Article
Open access
PDF file
XJXiuxiu Jin
Xiuxiu Jin
SMShuai Ming
Shuai Ming
JLJingyang Liu
Jingyang Liu
WWWeiping Wang
Weiping Wang
MLMeng Liu
Meng Liu
BLBo Lei
Bo Lei
X-linked retinoschisis (XLRS) is among the most commonly inherited degenerative retinopathies. XLRS is caused by functional impairment of RS1. However, the molecular mechanisms underlying RS1 malfunction remain largely uncharacterized. Here, we performed a data-independent acquisition-mass spectrometry-based proteomic analysis in RS1-null mouse retina with different postal days (Ps), including the onset (P15) and early progression stage (P56). Gene set enrichment analysis showed that type I interferon-mediated signaling was upregulated and photoreceptor proteins responsible for detection of light stimuli were downregulated at P15. Positive regulation of Tor signaling was downregulated and nuclear transcribed mRNA catabolic process nonsense-mediated decay was upregulated at P56. Moreover, the differentially expressed proteins at P15 were enriched in metabolism of RNA and RNA destabilization. A broader subcellular localization distribution and enriched proteins in visual perception and phototransduction were evident at P56. Combined transcriptomic-proteomic analysis revealed that functional impairments, including detection of visible light, visual perception, and visual phototransduction, occurred at P21 and continued until P56. Our work provides insights into the molecular mechanisms underlying the onset and progression of an XLRS mouse model during the early stages, thus enhancing the understanding of the mechanism of XLRS.

26 October 2022 in Biomolecules
Verified
Journal Article
Open access
PDF file
SYShun Yao
Shun Yao
SMShuai Ming
Shuai Ming
XJXiuxiu Jin
Xiuxiu Jin
MYMingzhu Yang
Mingzhu Yang
YLYa Li
Ya Li
BLBo Lei
Bo Lei
LHON is a common blinding inherited optic neuropathy caused by mutations in mitochondrial genes. In this study, by using skin fibroblasts derived from LHON patients with the most common m.G11778A mutation and healthy objects, we performed proteomic analysis to document changes in molecular proteins, signaling pathways and cellular activities. Furthermore, the results were confirmed by functional studies. A total of 860 differential expression proteins were identified, containing 624 upregulated and 236 downregulated proteins. Bioinformatics analysis revealed increased glycolysis in LHON fibroblasts. A glycolysis stress test showed that ECAR (extra-cellular acidification rate) values increased, indicating an enhanced level of glycolysis in LHON fibroblasts. Downregulated proteins were mainly enriched in oxidoreductase activity. Cellular experiments verified high levels of ROS in LHON fibroblasts, indicating the presence of oxidative damage. KEGG analysis also showed the metabolic disturbance of fatty acid in LHON cells. This study provided a proteomic profile of skin fibroblasts derived from LHON patients bearing m.G11778A. Increased levels of glycolysis, decreased oxidoreductase activity and fatty acid metabolism could represent the in-depth mechanisms of mitochondrial dysfunction mediated by the mutation. The results provided further evidence that LHON fibroblast could be an alternative model for investigating the devastating disease.