Abstract--Ultrasound therapy has been proven to be a method of ablating diseased blood vessels. Currently, experiments have proven that external pressure on the vascular region to be treated can effectively improve the success rate of closure. However, the degree of resulting thermal damage to surrounding tissue and the reason for the effects of compression on the shrinkage of tissue-encased blood vessels remain unclear. To address this issue, we conducted a study comparing the rate of shrinkage and surrounding tissue damage of compressed vessels encapsulated in muscle tissue to vessels with normal blood flow before and after treatment using the Simulation experiment and the ex-vivo tissue experiment. The results show that in the simulated model of compressed blood vessels with static blood flow, the temperature rise is significantly higher compared to the model with simulated blood flow. In the ex-vivo tissue experiment, the shrinkage rate of the blood vessel with static blood flow reaches up to 57% after the treatment, while the area of thermal damage is 28.8mm$^{2}$. In contrast, in the blood vessel with flowing blood, the vessels undergo almost no shrinkage but still cause 5.16mm$^{2}$ of thermal damage to the surrounding tissue. Our findings confirm that compressing the vessel is an effective and necessary step for the ultrasound closure of the vessel. But at the same time, to alleviate additional thermal damage, trying to change the way and position of the compression during treatment may be necessary.

18 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XJXie Jing
Xie Jing
WHWenchang Huang
Wenchang Huang
XLXinze Li
Xinze Li
JLJiaqi Li
Jiaqi Li
YXYiwen Xu
Yiwen Xu
YCYaoyao Cui
Yaoyao Cui
Varicose veins in the lower limb are a common and progressive venous disorder that can significantly reduce patients’ quality of life and pose a threat to their overall health if left untreated. However, current treatment approaches often involve invasive intervention. High-intensity focused ultrasound (HIFU) technology has the potential to treat varicose veins non-invasively, but most systems are bulky and expensive. This study proposes an innovative, integrated system that uses a 4.5 MHz therapeutic probe guided by a 12 MHz ultrasound imaging probe to treat varicose veins in the lower limb. The system aims to achieve high accuracy in repeated treatments by using a high-speed scanning positioning structure, increasing the imaging framerate, and reducing the system’s overall volume. The system’s accuracy is evaluated through reset error tests on an acrylic board, and its effectiveness is tested through in vivo experiments on rabbit marginal ear veins. Tests on porcine arteries are conducted to identify suitable focal points for vascular treatment. The experimental results demonstrate the system’s high accuracy, with a reset error of less than 0.07 mm, and an obvious shrinkage of the predetermined treatment area of the marginal ear veins after therapy. The study identifies that setting the focus on the vascular wall can improve the efficiency of vascular treatment, resulting in significant vasoconstriction changes. These experimental findings provide sufficient evidence for the system’s potential for clinical application in vascular treatment.