José Manuel González De Aledo-Castillo

Dr. José Manuel González De Aledo-Castillo

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2019 in Frontiers in Immunology
Verified
Journal Article
Open access
PDF file
AAAna Argudo-Ramírez
Ana Argudo-Ramírez
AMAndrea Martín-Nalda
Andrea Martín-Nalda
JMJose L. Marín-Soria
Jose L. Marín-Soria
RLRosa M. López-Galera
Rosa M. López-Galera
SPSonia Pajares-García
Sonia Pajares-García
PSPere Soler-Palacín
Pere Soler-Palacín
Severe combined immunodeficiency (SCID), the most severe form of T-cell immunodeficiency, can be screened at birth by quantifying T-cell receptor excision circles (TRECs) in dried blood spot (DBS) samples. Early detection of this condition speeds up the establishment of appropriate treatment and increases the patient's life expectancy. Newborn screening for SCID started in January 2017 in Catalonia, the first Spanish and European region to universally include this testing. The results obtained in the first 2 years of experience are evaluated here. All babies born between January 2017 and December 2018 were screened. TREC quantification in DBS (1.5 mm diameter) was performed with the Enlite Neonatal TREC kit from PerkinElmer (Turku, Finland). In 2018, the retest cutoff in the detection algorithm was updated based on the experience gained in the first year, and changed from 34 to 24 copies/μL. This decreased the retest rate from 3.34 to 1.4% (global retest rate, 2.4%), with a requested second sample rate of 0.23% and a positive detection rate of 0.02%. Lymphocyte phenotype (T, B, NK populations), expression of CD45RA/RO isoforms, percentage and intensity of TCR αβ and TCR γδ, presence of HLA-DR+ T lymphocytes, and in vitro lymphocyte proliferation were studied in all patients by flow cytometry. Of 130,903 newborns screened, 30 tested positive, 15 of which were male. During the study period, one patient was diagnosed with SCID: incidence, 1 in 130,903 births in Catalonia. Thirteen patients had clinically significant T-cell lymphopenia (non-SCID) with an incidence of 1 in 10,069 newborns (43% of positive detections). Nine patients were considered false-positive cases because of an initially normal lymphocyte count with normalization of TRECs between 3 and 6 months of life, four infants had transient lymphopenia due to an initially low lymphocyte count with recovery in the following months, and three patients are still under study. The results obtained provide further evidence of the benefits of including this disease in newborn screening programs. Longer follow-up is needed to define the exact incidence of SCID in Catalonia.

26 October 2015 in Chromatographia
Verified
Journal Article
Closed access
PDF file
RRRaúl Rigo-Bonnin
Raúl Rigo-Bonnin
AAAriadna Arbiol-Roca
Ariadna Arbiol-Roca
JAJosé Manuel González De Aledo-Castillo
José Manuel González De Aledo-Castillo
PAPedro Alía
Pedro Alía

Verified
Journal Article
Open access
PDF file
AAAna Argudo-Ramírez
Ana Argudo-Ramírez
AMAndrea Martín-Nalda
Andrea Martín-Nalda
JAJosé Manuel González De Aledo-Castillo
José Manuel González De Aledo-Castillo
RLRosa López-Galera
Rosa López-Galera
JMJose Luis Marín-Soria
Jose Luis Marín-Soria
PSPere Soler-Palacín
Pere Soler-Palacín
Newborn screening (NBS) for severe combined immunodeficiency (SCID) started in Catalonia in January-2017, being the first Spanish and European region to universally include this testing. In Spain, a pilot study with 5000 samples was carried out in Seville in 2014; also, a research project with about 35,000 newborns will be carried out in 2021–2022 in the NBS laboratory of Eastern Andalusia. At present, the inclusion of SCID is being evaluated in Spain. The results obtained in the first three and a half years of experience in Catalonia are presented here. All babies born between January-2017 and June-2020 were screened through TREC-quantification in DBS with the Enlite Neonatal TREC-kit from PerkinElmer. A total of 222,857 newborns were screened, of which 48 tested positive. During the study period, three patients were diagnosed with SCID: an incidence of 1 in 74,187 newborns; 17 patients had clinically significant T-cell lymphopenia (non-SCID) with an incidence of 1 in 13,109 newborns who also benefited from the NBS program. The results obtained provide further evidence of the benefits of early diagnosis and curative treatment to justify the inclusion of this disease in NBS programs. A national NBS program is needed, also to define the exact SCID incidence in Spain.

4 February 2024 in Journal of Lipid Research
Verified
Journal Article
Open access
BMBlai Morales-Romero
Blai Morales-Romero
JAJosé Manuel González De Aledo-Castillo
José Manuel González De Aledo-Castillo
CSCristina Fernández Sierra
Cristina Fernández Sierra
CCCarmen Martínez Carreira
Carmen Martínez Carreira
CBCarles Zaragoza Bonet
Carles Zaragoza Bonet
JVJudit García Villoria
Judit García Villoria
The gold-standard diagnostic test for peroxisomal disorders (PDs) is plasma concentration analysis of very long-chain fatty acids (VLCFAs). However, this method's time-consuming nature and limitations in cases which present normal VLCFA levels necessitates alternative approaches. The analysis of C26:0-lysophosphatydylcholine (C26:0-LPC) in dried blood spot samples by tandem-mass spectrometry (MS/MS) has successfully been implemented in certain newborn screening programs to diagnose X-linked adrenoleukodystrophy (ALD). However, the diagnostic potential of very long-chain LPCs concentrations in plasma remains poorly understood. This study sought to evaluate the diagnostic performance of C26:0-LPC and other very long-chain LPCs, comparing them to VLCFA analysis in plasma. The study, which included 330 individuals affected by a peroxisomal β-oxidation deficiency and 407 control individuals, revealed that C26:0- and C24:0-LPC concentrations demonstrated the highest diagnostic accuracy (98.8% and 98.4%, respectively), outperforming VLCFA when C26:0/C22:0 and C24:0/C22:0 ratios were combined (98.1%). Combining C24:0- and C26:0-LPC gave the highest sensitivity (99.7%), with ALD females exhibiting notably higher sensitivity compared with the VLCFA ratio combination (98.7% vs. 93.5%, respectively). In contrast, C22:0-LPC exhibited suboptimal performance, primarily due to its low sensitivity (75%), but we identified a potential use to help distinguish between ALD and Zellweger spectrum disorders. In summary, MS/MS analysis of plasma C24:0- and C26:0-LPC concentrations represents a rapid and straightforward approach to diagnose PDs, demonstrating superior diagnostic accuracy, particularly in ALD females, compared with conventional VLCFA biomarkers. We strongly recommend integrating very-long chain LPC plasma analysis in the diagnostic evaluation of individuals suspected of having a PD.

1 March 2020 in Molecular Genetics and Metabolism Reports
Verified
Journal Article
Open access
SPS. Pajares
S. Pajares
RLR.M. López
R.M. López
LGL. Gort
L. Gort
AAAna Argudo-Ramírez
Ana Argudo-Ramírez
JMJ.L. Marín
J.L. Marín
ARAntonia Ribes
Antonia Ribes
Short-chain enoyl-CoA hydratase (ECHS1) is a mitochondrial beta-oxidation enzyme involved in the metabolism of acyl-CoA fatty acid esters, as well as in valine metabolism. ECHS1 deficiency has multiple manifestations, including Leigh syndrome early at birth or in childhood with poor prognosis, to cutis laxa, exercise-induced dystonia and congenital lactic acidosis. Here we describe the case of a newborn with mutations in ECHS1 that caught our attention after the incidental finding of 3-hydroxy-butyryl\3-hydroxy-isobutyryl\malonylcarnitine (C4OH\C3DC) and tiglylcarnitine (C5:1) on blood spot in the newborn screening (NBS) program. Diagnosis was suspected based on the analysis of organic acids on dried urine spot. A moderate increase of 2-methyl-2,3-dihydroxybutyric acid, was detected, which is a known marker of this disease. Exome analysis showed c.404A>G (p.Asn135Ser) mutation in homozygosis in the ECHS1 gene. The child was therefore admitted to the hospital. Initial examination showed little response to auditory stimuli and mild hypertonia of the extremities. Clinical deterioration was evident at 4 months of age, including neurological and cardiac involvement, and the patient died at 5 months of age. This case illustrates how an incidental detection in the NBS Program can lead to the diagnosis ECHS1 deficiency. Although it is a severe disease, with no treatment available, early detection would allow adequate genetic counseling avoiding the odyssey that suffered most of these families.

1 October 2015 in Transplantation Proceedings
Verified
Journal Article
Closed access
AAAna Argudo-Ramírez
Ana Argudo-Ramírez
JAJosé Manuel González De Aledo-Castillo
José Manuel González De Aledo-Castillo
PAP. Alía
P. Alía
PRP. Ramírez
P. Ramírez
TST. Serrano
T. Serrano
JCJ. Castellote
J. Castellote