Gordon Alderink

Dr. Gordon Alderink

Frederik Meijer Honors College, Grand Valley State University, Grand Rapids, MI 49401, USA
orcid
Retired physical therapy faculty from Grand Valley State Uni...

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NTNatalie Tipton
Natalie Tipton
Gordon AlderinkGordon Alderink
Gordon Alderink
SRSamhita Rhodes
Samhita Rhodes
The body’s postural control system is responsible for responding to perturbations of balance and keeping the body upright. During quiet standing, the center of pressure oscillates about the center of mass, counteracting imbalances. These oscillations can be analyzed to determine the degree of stability, which could be helpful in quantifying the effects of brain injuries. In this research, the center of pressure was recorded for stances with feet together and feet tandem, with eyes opened and eyes closed, in neurotypical participants. These signals were analyzed using indices of approximate entropy and velocity to determine how sensitive the measures were in tracking changes to stability levels. One-way ANOVA test results showed increased approximate entropy in anterior/posterior and medial/lateral directions (p = 1.21 × 10−11, 3 × 10−14) and increased velocity in both directions (p = 2.87 × 10−6, 4.87 × 10−7) during conditions with decreased stability. Dunnett’s post hoc testing indicated that approximate entropy was significantly greater in all the less stable feet tandem trials in comparison to the most stable eyes open, feet together condition with p < 0.001 in nearly every participant and that velocity was significantly greater in the least stable eyes closed, feet tandem trials in comparison to the most stable condition with p < 0.01 in nearly every participant.

5 March 2021 in Journal of Biomechanics
Verified
Journal Article
Closed access
Gordon AlderinkGordon Alderink
Gordon Alderink
TKTom Kepple
Tom Kepple
SSSteven J. Stanhope
Steven J. Stanhope
AAArnel Aguinaldo
Arnel Aguinaldo

3 October 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
Gordon AlderinkGordon Alderink
Gordon Alderink
Sylvia OunpuuSylvia Ounpuu
Sylvia Ounpuu
A review of the methods and applications of marker-based and markerless-based motion capture and inertial measurement units for clinical gait analysis is offered to provide readers with an important historical and legacy-guided perspective. Advantages and limitations of these methods are delineated in light of Cappozzo’s ‘considerations on clinical gait evaluation’ and Brand and Crowninshield’s ‘comment on criteria for patient evaluation tools’. Critical summaries of each manuscript that make up this Special Issue reflect consideration of the notable comments by the legacy biomechanists who had the insights to frame important issues.

3 February 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CHCathy C. C Harro
Cathy C. C Harro
Gordon AlderinkGordon Alderink
Gordon Alderink
LHLauren Hickox
Lauren Hickox
DZDavid Zeitler
David Zeitler
MAMichele Avery
Michele Avery
DLDori Laker
Dori Laker
Individuals with Parkinson’s disease (PD) have postural instability and gait dysfunction that lead to falls and disability with disease progression. Increased fall risk is particularly seen during challenging gait tasks such as obstacle-crossing. The purpose of this study was to determine if there were differences in dynamic postural control during self-paced walking and obstacle-crossing between persons with mild-to-moderate PD and healthy controls. Participants included nine individuals with PD and nine age- and gender-matched controls (CON). This study examined margin of stability metrics using instrumented 3D motion analysis during the two-step sequence of the obstacle-crossing task. Dynamic balance variables and spatiotemporal (ST) parameters at distinct gait events related to the leading (step one) and trailing leg (step two) were compared for the PD and CON groups using a mixed-model ANOVA. No differences were found between groups for ST gait parameters during obstacle-crossing, except for a significantly reduced step length (p = 0.005) for the trailing limb for the PD group. The PD group demonstrated significantly larger mean values for mediolateral center of pressure–center of mass (COP–COM) distance at first double support (p = 0.004) and center of pressure–extrapolated center of mass (COP–XCOM) distance at second double support (p = 0.016) for the second step. Our results suggest that the margin of stability may be useful in discerning postural control adaptations during obstacle negotiation in persons with PD.

19 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BHBarbara J. Hoogenboom
Barbara J. Hoogenboom
CMChristopher J. May
Christopher J. May
Gordon AlderinkGordon Alderink
Gordon Alderink
BTBrian S. Thompson
Brian S. Thompson
LGLukas A. Gilmore
Lukas A. Gilmore
The squat, a fundamental functional movement, is prone to biomechanical inefficiencies. Several screening batteries utilize the Overhead Deep Squat (OHDS) to assess individuals for stability and mobility deficits. The purpose of this study was to create a comprehensive description of the three-dimensional (3D) kinematics and kinetics for normal, healthy participants during an overhead deep squat. This descriptive study containing 70 healthy young adults (31 male, 39 female; aged 18–35) utilized a video motion tracking system interfaced with force plates to obtain full-body 3D kinematics and kinetics. Seventy-three retro-reflective markers from the combined Plug-in Gait, Vicon upper limb, and Oxford Multi-segment foot models were used. Visual 3D software was used to determine joint kinematics and kinetics. Means and standard deviations of lower limb and trunk segment joint angles in the sagittal, transverse, and horizontal planes, as well as the ground reaction forces and net internal joint moments, were computed. The largest movements and joint moments occurred in the sagittal plane; however, the frontal and transverse plane appear crucial to providing stability and mobility. These results can be used as pilot normative data for both future studies and during assessments of biomechanical abnormalities in training and rehabilitation settings.

9 January 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JWJayla Wesley
Jayla Wesley
SRSamhita Rhodes
Samhita Rhodes
DZDavid Zeitler
David Zeitler
Gordon AlderinkGordon Alderink
Gordon Alderink
Approximate entropy (ApEn) and sample entropy (SampEn) are statistical indices designed to quantify the regularity or predictability of time-series data. Although ApEn has been a prominent choice in analyzing non-linear data, it is currently unclear which method and parameter selection combination is optimal for its application in biomechanics. This research aimed to examine the differences between ApEn and SampEn related to center-of-pressure (COP) data during tandem standing balance tasks, while also changing the tolerance window, r. Six participants completed five, 30 s trials, feet-together and tandem standing with eyes open and eyes closed. COP data (fs = 60 Hz, downsampled from 1200 Hz) from ground reaction force platforms were collected. ApEn and SampEn were calculated using a constant vector length, i.e., m = 2, but differing values of r (tolerance window). For each of the participants, four separate one-way analysis of variance analyses (ANOVA) were conducted for ApEn and SampEn along the anterior–posterior (AP) and medial–lateral (ML) axes. Dunnett’s intervals were applied to the one-way ANOVA analyses to determine which tandem conditions differed significantly from the baseline condition. ApEn and SampEn provided comparable results in the predictability of patterns for different stability conditions, with increasing instability, i.e., tandem eyes closed postures, being associated with greater unpredictability. The selection of r had a relatively consistent effect on mean ApEn and SampEn values across r = 0.15 × SD to r = 0.25 × SD, where both entropy methods tended to decrease as r increased. Mean SampEn values were generally lower than ApEn values. The results suggest that both ApEn and SampEn indices demonstrated relative consistency and were equally effective in quantifying the level of the center-of-pressure signal regularity during quiet tandem standing postural balance tests.