Juan Flores-Montero

Dr. Juan Flores-Montero

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2012 in Leukemia
Verified
Journal Article
Open access
JDJacques J.M. van Dongen
Jacques J.M. van Dongen
LLL Lhermitte
L Lhermitte
SBS Böttcher
S Böttcher
JAJ Almeida
J Almeida
VVV H J van der Velden
V H J van der Velden
AOA Orfao
A Orfao
Most consensus leukemia & lymphoma antibody panels consist of lists of markers based on expert opinions, but they have not been validated. Here we present the validated EuroFlow 8-color antibody panels for immunophenotyping of hematological malignancies. The single-tube screening panels and multi-tube classification panels fit into the EuroFlow diagnostic algorithm with entries defined by clinical and laboratory parameters. The panels were constructed in 2–7 sequential design–evaluation–redesign rounds, using novel Infinicyt software tools for multivariate data analysis. Two groups of markers are combined in each 8-color tube: (i) backbone markers to identify distinct cell populations in a sample, and (ii) markers for characterization of specific cell populations. In multi-tube panels, the backbone markers were optimally placed at the same fluorochrome position in every tube, to provide identical multidimensional localization of the target cell population(s). The characterization markers were positioned according to the diagnostic utility of the combined markers. Each proposed antibody combination was tested against reference databases of normal and malignant cells from healthy subjects and WHO-based disease entities, respectively. The EuroFlow studies resulted in validated and flexible 8-color antibody panels for multidimensional identification and characterization of normal and aberrant cells, optimally suited for immunophenotypic screening and classification of hematological malignancies.

5 September 2012 in Leukemia
Verified
Journal Article
Open access
PDF file
TKT Kalina
T Kalina
JFJuan Flores-Montero
Juan Flores-Montero
VVV H J van der Velden
V H J van der Velden
MMM Martin-Ayuso
M Martin-Ayuso
SBS Böttcher
S Böttcher
AOA Orfao
A Orfao
The EU-supported EuroFlow Consortium aimed at innovation and standardization of immunophenotyping for diagnosis and classification of hematological malignancies by introducing 8-color flow cytometry with fully standardized laboratory procedures and antibody panels in order to achieve maximally comparable results among different laboratories. This required the selection of optimal combinations of compatible fluorochromes and the design and evaluation of adequate standard operating procedures (SOPs) for instrument setup, fluorescence compensation and sample preparation. Additionally, we developed software tools for the evaluation of individual antibody reagents and antibody panels. Each section describes what has been evaluated experimentally versus adopted based on existing data and experience. Multicentric evaluation demonstrated high levels of reproducibility based on strict implementation of the EuroFlow SOPs and antibody panels. Overall, the 6 years of extensive collaborative experiments and the analysis of hundreds of cell samples of patients and healthy controls in the EuroFlow centers have provided for the first time laboratory protocols and software tools for fully standardized 8-color flow cytometric immunophenotyping of normal and malignant leukocytes in bone marrow and blood; this has yielded highly comparable data sets, which can be integrated in a single database.

20 January 2017 in Leukemia
Verified
Journal Article
Open access
JFJuan Flores-Montero
Juan Flores-Montero
LSL Sanoja-Flores
L Sanoja-Flores
BPB Paiva
B Paiva
NPN Puig
N Puig
OGO García-Sánchez
O García-Sánchez
AOAlberto Orfao
Alberto Orfao
Flow cytometry has become a highly valuable method to monitor minimal residual disease (MRD) and evaluate the depth of complete response (CR) in bone marrow (BM) of multiple myeloma (MM) after therapy. However, current flow-MRD has lower sensitivity than molecular methods and lacks standardization. Here we report on a novel next generation flow (NGF) approach for highly sensitive and standardized MRD detection in MM. An optimized 2-tube 8-color antibody panel was constructed in five cycles of design-evaluation-redesign. In addition, a bulk-lysis procedure was established for acquisition of ⩾107 cells/sample, and novel software tools were constructed for automatic plasma cell gating. Multicenter evaluation of 110 follow-up BM from MM patients in very good partial response (VGPR) or CR showed a higher sensitivity for NGF-MRD vs conventional 8-color flow-MRD -MRD-positive rate of 47 vs 34% (P=0.003)-. Thus, 25% of patients classified as MRD-negative by conventional 8-color flow were MRD-positive by NGF, translating into a significantly longer progression-free survival for MRD-negative vs MRD-positive CR patients by NGF (75% progression-free survival not reached vs 7 months; P=0.02). This study establishes EuroFlow-based NGF as a highly sensitive, fully standardized approach for MRD detection in MM which overcomes the major limitations of conventional flow-MRD methods and is ready for implementation in routine diagnostics.

10 March 2020 in Journal of Clinical Oncology
Verified
Journal Article
Closed access
BPBruno Paiva
Bruno Paiva
NPNoemi Puig
Noemi Puig
MCMaria-Teresa Cedena
Maria-Teresa Cedena
LRLaura Rosiñol
Laura Rosiñol
LCLourdes Cordón
Lourdes Cordón
OGon behalf of the GEM (Grupo Español de Mieloma)/PETHEMA (Programa Para el Estudio de la Terapéutica en Hemopatías Malignas) Cooperative Study Group
on behalf of the GEM (Grupo Español de Mieloma)/PETHEMA (Programa Para el Estudio de la Terapéutica en Hemopatías Malignas) Cooperative Study Group
PURPOSE: Assessing measurable residual disease (MRD) has become standard with many tumors, but the clinical meaning of MRD in multiple myeloma (MM) remains uncertain, particularly when assessed by next-generation flow (NGF) cytometry. Thus, we aimed to determine the applicability and sensitivity of the flow MRD-negative criterion defined by the International Myeloma Working Group (IMWG). PATIENTS AND METHODS: In the PETHEMA/GEM2012MENOS65 trial, 458 patients with newly diagnosed MM had longitudinal assessment of MRD after six induction cycles with bortezomib, lenalidomide, and dexamethasone (VRD), autologous transplantation, and two consolidation courses with VRD. MRD was assessed in 1,100 bone marrow samples from 397 patients; the 61 patients without MRD data discontinued treatment during induction and were considered MRD positive for intent-to-treat analysis. The median limit of detection achieved by NGF was 2.9 × 10−6. Patients received maintenance (lenalidomide ± ixazomib) according to the companion PETHEMA/GEM2014MAIN trial. RESULTS: Overall, 205 (45%) of 458 patients had undetectable MRD after consolidation, and only 14 of them (7%) have experienced progression thus far; seven of these 14 displayed extraosseous plasmacytomas at diagnosis and/or relapse. Using time-dependent analysis, patients with undetectable MRD had an 82% reduction in the risk of progression or death (hazard ratio, 0.18; 95% CI, 0.11 to 0.30; P < .001) and an 88% reduction in the risk of death (hazard ratio, 0.12; 95% CI, 0.05 to 0.29; P < .001). Timing of undetectable MRD (after induction v intensification) had no impact on patient survival. Attaining undetectable MRD overcame poor prognostic features at diagnosis, including high-risk cytogenetics. By contrast, patients with Revised International Staging System III status and positive MRD had dismal progression-free and overall survivals (median, 14 and 17 months, respectively). Maintenance increased the rate of undetectable MRD by 17%. CONCLUSION: The IMWG flow MRD-negative response criterion is highly applicable and sensitive to evaluate treatment efficacy in MM.

23 June 2015 in Cytometry Part B: Clinical Cytometry
Verified
Journal Article
Closed access
PDF file
JFJuan Flores-Montero
Juan Flores-Montero
RTRuth de Tute
Ruth de Tute
Bruno David Lourenco PaivaBruno David Lourenco Paiva
Bruno David Lourenco Paiva
JPJosé Juan Perez
José Juan Perez
SBSebastian Böttcher
Sebastian Böttcher
AOAlberto Orfao
Alberto Orfao

23 October 2014 in Cytometry Part A
Verified
Journal Article
Open access
PDF file
TKTomas Kalina
Tomas Kalina
JFJuan Flores-Montero
Juan Flores-Montero
QLQuentin Lecrevisse
Quentin Lecrevisse
CPCarlos E. Pedreira
Carlos E. Pedreira
VVVincent H. J. van der Velden
Vincent H. J. van der Velden
AOAlberto Orfao
Alberto Orfao
Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato‐oncology. The EuroFlow Consortium has established a fully standardized “all‐in‐one” pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for laboratories that use standardized EuroFlow protocols. It may be used to complement, but not replace, established proficiency tests. © 2014 International Society for Advancement of Cytometry