Diego Lopez-Garcia

Dr. Diego Lopez-Garcia

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Engineering Structures
Verified
Journal Article
Closed access
RRRafael O. Ruiz
Rafael O. Ruiz
ATA.A. Taflanidis
A.A. Taflanidis
Agathoklis GiaralisAgathoklis Giaralis
Agathoklis Giaralis
Diego Lopez-GarciaDiego Lopez-Garcia
Diego Lopez-Garcia

1 November 2008 in Journal of Bridge Engineering
Verified
Journal Article
Closed access
SFShuichi Fujikura
Shuichi Fujikura
MBMichel Bruneau
Michel Bruneau
Diego Lopez-GarciaDiego Lopez-Garcia
Diego Lopez-Garcia
This paper presents the development and experimental validation of a multizard bridge pier concept, i.e., a bridge pier system capable of providing an adequate level of protection against collapse under seismic and blast loading (but not acting simultaneously). A multicolumn pier-bent with concrete-filled steel tube (CFST) columns is the proposed concept, and the adequacy of this system is experimentally investigated under blast loading. This paper describes simplified blast analysis, multihazard design of bridge piers, and blast experimental program and results. Additionally, the results from the blast experiments are compared with the results from the simplified method of analysis considering an equivalent single degree of freedom system having an elastic-perfectly plastic behavior. It is found that prototype bridge CFST columns can be designed to provide both satisfactory seismic performance and adequate blast resistance. It is also shown that the CFST columns exhibited a ductile behavior under blast load in a series of tests at 1∕4 scale. Maximum deformation of the columns could be calculated using simplified analysis considering a factor to account for the reduction of pressures on the circular column and determined from this experimental program.

29 October 2002 in Earthquake Engineering & Structural Dynamics
Verified
Journal Article
Closed access
PDF file
Diego Lopez-GarciaDiego Lopez-Garcia
Diego Lopez-Garcia
TST. T. Soong
T. T. Soong

1 July 2007 in Engineering Structures
Verified
Journal Article
Closed access
JAJosé L. Almazán
José L. Almazán
JLJuan C. De la Llera
Juan C. De la Llera
JIJosé A. Inaudi
José A. Inaudi
Diego Lopez-GarciaDiego Lopez-Garcia
Diego Lopez-Garcia
LILuis E. Izquierdo
Luis E. Izquierdo

1 October 2014 in Journal of Constructional Steel Research
Verified
Journal Article
Closed access
FFFrancisco X. Flores
Francisco X. Flores
FCFinley A. Charney
Finley A. Charney
Diego Lopez-GarciaDiego Lopez-Garcia
Diego Lopez-Garcia

1 September 2014 in Journal of Structural Engineering
Verified
Journal Article
Closed access
GCG. P. Cimellaro
G. P. Cimellaro
TGT. Giovine
T. Giovine
Diego Lopez-GarciaDiego Lopez-Garcia
Diego Lopez-Garcia
Pushover analysis is one of the most-used nonlinear static procedures for the seismic assessment of structures; therefore, nowadays it is extensively used by practicing engineers for the seismic analysis of virtually every type of building. This paper proposes a bidirectional pushover analysis (BPA) method to overcome the limitations of current pushover methods to assess the seismic response of irregular (both in plan and in elevation) buildings subjected to bidirectional ground motions. The extended N2 method and the proposed BPA method were applied to estimate the nonlinear response of six highly irregular reinforced concrete frame structures designed according to the requirements of Eurocode 8. Results in terms of interstory drifts and floor rotations are compared with those given by nonlinear response history analysis (NRHA). For the latter, a suite of twenty Italian bidirectional seismic ground motions was selected. It was found that results given by the proposed BPA method match those given by NRHA when the earthquake loadings are considered to act simultaneously in two principal orthogonal directions (X and Y) with load factors of 1 and 0.6, respectively. These load factors are different from the values of 1 and 0.3 indicated in the European seismic code for bidirectional linear analysi