Su Kyoung Kim

Dr. Su Kyoung Kim


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SKSu Kyoung Kim
Su Kyoung Kim
EKElsa Andrea Kirchner
Elsa Andrea Kirchner
ASArne Stefes
Arne Stefes
FKFrank Kirchner
Frank Kirchner
Reinforcement learning (RL) enables robots to learn its optimal behavioral strategy in dynamic environments based on feedback. Explicit human feedback during robot RL is advantageous, since an explicit reward function can be easily adapted. However, it is very demanding and tiresome for a human to continuously and explicitly generate feedback. Therefore, the development of implicit approaches is of high relevance. In this paper, we used an error-related potential (ErrP), an event-related activity in the human electroencephalogram (EEG), as an intrinsically generated implicit feedback (rewards) for RL. Initially we validated our approach with seven subjects in a simulated robot learning scenario. ErrPs were detected online in single trial with a balanced accuracy (bACC) of 91%, which was sufficient to learn to recognize gestures and the correct mapping between human gestures and robot actions in parallel. Finally, we validated our approach in a real robot scenario, in which seven subjects freely chose gestures and the real robot correctly learned the mapping between gestures and actions (ErrP detection (90% bACC)). In this paper, we demonstrated that intrinsically generated EEG-based human feedback in RL can successfully be used to implicitly improve gesture-based robot control during human-robot interaction. We call our approach intrinsic interactive RL.

3 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
HWHendrik Woehrle
Hendrik Woehrle
MTMarc Tabie
Marc Tabie
SKSu Kyoung Kim
Su Kyoung Kim
FKFrank Kirchner
Frank Kirchner
EKElsa Andrea Kirchner
Elsa Andrea Kirchner
A current trend in the development of assistive devices for rehabilitation, for example exoskeletons or active orthoses, is to utilize physiological data to enhance their functionality and usability, for example by predicting the patient’s upcoming movements using electroencephalography (EEG) or electromyography (EMG). However, these modalities have different temporal properties and classification accuracies, which results in specific advantages and disadvantages. To use physiological data analysis in rehabilitation devices, the processing should be performed in real-time, guarantee close to natural movement onset support, provide high mobility, and should be performed by miniaturized systems that can be embedded into the rehabilitation device. We present a novel Field Programmable Gate Array (FPGA) -based system for real-time movement prediction using physiological data. Its parallel processing capabilities allows the combination of movement predictions based on EEG and EMG and additionally a P300 detection, which is likely evoked by instructions of the therapist. The system is evaluated in an offline and an online study with twelve healthy subjects in total. We show that it provides a high computational performance and significantly lower power consumption in comparison to a standard PC. Furthermore, despite the usage of fixed-point computations, the proposed system achieves a classification accuracy similar to systems with double precision floating-point precision.

15 October 2020 in Frontiers in Robotics and AI
Verified
Journal Article
Open access
PDF file
SKSu Kyoung Kim
Su Kyoung Kim
EKElsa Andrea Kirchner
Elsa Andrea Kirchner
LSLukas Schloßmüller
Lukas Schloßmüller
FKFrank Kirchner
Frank Kirchner
During human-robot interaction, errors will occur. Hence, understanding the effects of interaction errors and especially the effect of prior knowledge on robot learning performance is relevant to develop appropriate approaches for learning under natural interaction conditions, since future robots will continue to learn based on what they have already learned. In this study, we investigated interaction errors that occurred under two learning conditions, i.e., in the case that the robot learned without prior knowledge (cold-start learning) and in the case that the robot had prior knowledge (warm-start learning). In our human-robot interaction scenario, the robot learns to assign the correct action to a current human intention (gesture). Gestures were not predefined but the robot had to learn their meaning. We used a contextual-bandit approach to maximize the expected payoff by updating (a) the current human intention (gesture) and (b) the current human intrinsic feedback after each action selection of the robot. As an intrinsic evaluation of the robot behavior we used the error-related potential (ErrP) in the human electroencephalogram as reinforcement signal. Either gesture errors (human intentions) can be misinterpreted by incorrectly captured gestures or errors in the ErrP classification (human feedback) can occur. We investigated these two types of interaction errors and their effects on the learning process. Our results show that learning and its online adaptation was successful under both learning conditions (except for one subject in cold-start learning). Furthermore, warm-start learning achieved faster convergence, while cold-start learning was less affected by online changes in the current context.

19 July 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NKNiklas Kueper
Niklas Kueper
SKSu Kyoung Kim
Su Kyoung Kim
EKElsa Andrea Kirchner
Elsa Andrea Kirchner
Exoskeleton-based support for patients requires the learning of individual machine-learning models to recognize movement intentions of patients based on the electroencephalogram (EEG). A major issue in EEG-based movement intention recognition is the long calibration time required to train a model. In this paper, we propose a transfer learning approach that eliminates the need for a calibration session. This approach is validated on healthy subjects in this study. We will use the proposed approach in our future rehabilitation application, where the movement intention of the affected arm of a patient can be inferred from the EEG data recorded during bilateral arm movements enabled by the exoskeleton mirroring arm movements from the unaffected to the affected arm. For the initial evaluation, we compared two trained models for predicting unilateral and bilateral movement intentions without applying a classifier transfer. For the main evaluation, we predicted unilateral movement intentions without a calibration session by transferring the classifier trained on data from bilateral movement intentions. Our results showed that the classification performance for the transfer case was comparable to that in the non-transfer case, even with only 4 or 8 EEG channels. Our results contribute to robotic rehabilitation by eliminating the need for a calibration session, since EEG data for training is recorded during the rehabilitation session, and only a small number of EEG channels are required for model training.

30 September 2017 in Korean Journal of Environmental Biology
Verified
Journal Article
Closed access
SBSun-Hye Bae
Sun-Hye Bae
KKKi Wook Kim
Ki Wook Kim
SKSu Kyoung Kim
Su Kyoung Kim
JKJong-Hyun Kim
Jong-Hyun Kim
Jun-Hwan KimJun-Hwan Kim
Jun-Hwan Kim

1 January 2007
Verified
Conference Paper
Closed access
SKSu Kyoung Kim
Su Kyoung Kim
This study is, after analyze of Semantic Web Application and Web ontology characteristics, established inference-based web ontology that use expression of Description Logic and SWRL, and verified inference that established Web Ontologies. Especially, this study there is the merit that can recreate new Ontology through inference. Be it performs an inference rule defined, and to generate a new Ontology file through knowledge base ontologies. This the way that can achieve an important purpose called reuse and sharing under functions of ontology. Implemented a Test System to support an Intelligent Image Retrieval based on that established web ontologies. The test result, Semantic Web Application use inference-based web ontology showed with excellent performance in recall ratio and correctness rates than target system that use annotation-based ontology.