In terms of load transfer, the design of the joints in concrete-filled steel tubular (CFST) arch bridges is more critical than that in buildings due to the higher likelihood of steel–concrete-interface debonding. To improve the contact at the steel–concrete interface, a novel arch rib was manufactured by longitudinally welding perfobond-rib-shear connectors to the inner surface of a steel tube and then filling the tube with concrete. In this study, extensive numerical and analytical investigations on the mechanism of introducing loads into CFST arch ribs through perfobond-rib-shear connectors were carried out. A deck CFST arch bridge, namely, the Shuangbao Bridge in China, was selected as a typical application location. The design parameters, including the geometric dimensions of the perfobond-rib-shear connector and the arrangement of the perfobond rib along the cross-section and longitudinal section of the arch rib, were evaluated. The design flow for the joint with perfobond-rib-shear connectors between the vertical columns and the CFST arch ribs was proposed. To improve the load-transfer efficiency, the design scheme of the joint in the Shuangbao Bridge was optimized by replacing the weld studs with perfobond ribs. Significant increases of 1.84–4.02 in the shear resistance were found for the perfobond ribs compared to the welded studs. Additionally, the fabrication of the perfobond ribs was more convenient compared to that of the welded studs.
9 June 2022 in Advances in Materials Science and Engineering
With the rapid development of underground engineering construction, such as deep mining of mineral resources and tunnel excavation under complex geological conditions, the existing support methods cannot meet the deformation requirements. It is necessary to conduct in-depth research on the stress status and damage evolution of the hanger rods, to establish a theoretical basis for the design principles and criteria of key components. In this paper, the degradation law of the mechanical properties of the hanger steel wire with the degree of corrosion is analyzed in detail. The results show that the corrosion changes the geometry of the cross section of the steel wire, which leads to the degradation of the mechanical properties of the steel wire. With the increase of corrosion length and depth, the strength, stiffness, and ultimate strain of the steel wire are reduced to varying degrees, and the effect of pitting corrosion is more significant than that of uniform corrosion. The closer the holes are, the greater the corrosion effect is.
The study aims to further standardize the construction process, improve the construction quality, and ensure the stability of infrastructure construction. The continuous rigid-frame bridge is taken as the research object, the finite element model of the bridge body is established by using the beam element, and the overall stability of the rigid-frame bridge is analyzed in the construction and completion stages. Moreover, the stability coefficient and buckling mode are established under different working conditions in each stage, the linear stability variation law is summarized, and the geometric nonlinear stability analysis method is established through the specific data. The nonlinear stability safety factor and buckling mode are obtained, and the influence of wind load and initial defects on the stability of continuous rigid-frame bridge is further explored. The results show that with the increase of the bridge height, the overall stability factor of the bridge is decreasing, and the safety factor of the single-limb thin-walled hollow pier is relatively larger than that of the double-limb thin-walled hollow pier. During the construction, the asymmetric self-weight load caused by the asynchronous load and cantilever pouring has the greatest impact on the stability of the bridge. The stability safety factor of the geometric nonlinear stability analysis method constructed is 0.3% and 1.27% lower than the ideal state, respectively. The stability safety factor of the wind load and the initial defect is 12.65% lower than the ideal state, and the stability safety factor is greatly reduced. The results have important reference significance to ensure the construction safety and overall stability of the bridge.
During the operational phase of a bridge, the crossbeam, acting as a supporting member, plays an important role in keeping the cross-sectional shape constant in addition to resisting against various lateral and longitudinal loads and distributing the dead and the live loads to the adjacent main girders. The complex functional requirements lead to a complex internal force composition of the crossbeam. When subjected to torque, the two main beams of the twin I-girder bridge will have deformation in opposite longitudinal directions (known as warping deformation) to counteract the torque. The existing research has not considered the impact of main beam warping deformation on the internal force of the crossbeam. Based on the existing research, this article further considers the impact of main beam warping deformation on the internal force of the crossbeam, making the calculation of the internal force of the crossbeam more accurate. The results show that the torsional characteristics of the continuous twin I-girder bridge can be calculated using Vlasov’s theory of thin-walled structures combined with the displacement method. As for the effect of the crossbeam on the torsional stiffness of the structure, it can be managed by making the crossbeam stiffness continuous; however, in general, the equivalent stiffness is small compared to the stiffness of the main beam and it can be ignored. The crossbeam can be simplified to a bar with two solid ends for the internal force calculation whose formula is proposed in this paper, based on the existing frame model, and it can further consider the influence of warping deformation of the main beam on the internal force of the beam, and the calculation accuracy is high.