Saroa Rozas

Dr. Saroa Rozas

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Journal of Environmental Radioactivity
Verified
Journal Article
Closed access
SRSaroa Rozas
Saroa Rozas
RIRaquel Idoeta
Raquel Idoeta
Natalia AlegríaNatalia Alegría
Natalia Alegría
MHM. Herranz
M. Herranz

1 October 2017 in Journal of Environmental Radioactivity
Verified
Journal Article
Closed access
MHM. Herranz
M. Herranz
RIRaquel Idoeta
Raquel Idoeta
SRSaroa Rozas
Saroa Rozas
FLF. Legarda
F. Legarda

8 November 2018 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Closed access
PDF file
RIRaquel Idoeta
Raquel Idoeta
SRSaroa Rozas
Saroa Rozas
COConcepcion Olondo
Concepcion Olondo
APA. Párraga
A. Párraga
MHM. Herranz
M. Herranz

1 October 2021 in Applied Radiation and Isotopes
Verified
Journal Article
Open access
SRSaroa Rozas
Saroa Rozas
MHM. Herranz
M. Herranz
RIRaquel Idoeta
Raquel Idoeta
Determination of 241Pu is an essential issue for radiation protection, as it is the precursor of some nuclides with high radiotoxicity. 241Pu is a low energy beta emitter, which makes its measurement more challenging than that of Pu alpha emitters. The most widely used method for the measurement of 241Pu is liquid scintillation counting (LSC). In this method, the assessment of Pu radiochemical yield is done by measuring the sample by alpha spectrometry before being lixiviated and measured by LSC. This double measurement affects uncertainty analysis, as well as decision threshold and detection limit, considering that both components of the total yield (radiochemical and lixiviation) should be contemplated. In this paper, and for quality assurance (QA) purposes, in-depth uncertainty and detection limit formulae for the proposed method, controlling correlations and considering all the parameters involved including chemical and lixiviation yields, have been developed. A sensitivity analysis of the uncertainty budget together with an assessment of 242Pu tracer quantity to be used, ensuring a total yield of at least 50% and a relative uncertainty of the leaching yield of at most 5%, have been carried out. In addition, an analysis of the impact of the real lixiviation yield value and its uncertainty on the results has been done. As a general conclusion, and considering the values of the parameters chosen for this work (samples of 1 g measured for 24 h by LSC), the 241Pu uncertainties range from 5% to 30% depending on the activity concentration values and the detection limits range from 14 to 30 Bq kg-1, depending on yield values. The main components of the uncertainty budget are the net 241Pu and background counts obtained in the LSC measurement for low contaminated samples while this is the case for the alpha gross count rate in LSC measurement of the alpha calibration source for highly contaminated samples. In addition, an analysis of possible interference by Pu alpha emitters in the 241Pu signal and a comparison of quench standard curves of 3H and 241Pu are also performed.

9 June 2023 in Environments
Verified
Journal Article
Open access
PDF file
SRSaroa Rozas
Saroa Rozas
RIRaquel Idoeta
Raquel Idoeta
MRMaría Teresa Rodríguez
María Teresa Rodríguez
MSMargarita Herranz Soler
Margarita Herranz Soler
Today, the measurement of 14C in environmental samples is of particular interest, as it enables the assessment of the impact caused by nuclear activities and the fossil fuel industry on the environment. In order to assure the quality of 14C measurement results, the strategy to enlarge the validation of three radioanalytical methods in environmental samples using liquid scintillation spectrometry—the direct counting of water, bubbling of water and combustion of solids—is presented. Due certain difficulties, such as the lack of quality control materials and the scarcity of proficiency test and intercomparison exercises, especially in solid samples, a set of water and soil samples were prepared for the purpose by tracing them with known quantities of a 14C standard solution at two activity levels. Aliquots were subjected to the corresponding method and their activity concentration was calculated. Finally, uncertainty, detection limit, accuracy, precision, repeatability and linearity were analysed. The acceptance criteria for the quality parameters were previously established according to ISO 13528:2015 standard and Eurachem Laboratory Guide to Method Validation. In all the methods, the studied parameters fall within the acceptance range, so they are validated. The quality of the results in real samples is controlled through field validation.

29 April 2022 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Open access
PDF file
SRSaroa Rozas
Saroa Rozas
JLJulen López
Julen López
RIRaquel Idoeta
Raquel Idoeta
MHMargarita Herranz
Margarita Herranz
In this work, two Tc radiochemical isolation methods—a conventional method by Triskem TEVA® resin and a rapid method by Empore™ Tc Rad Disk—are compared in the field of nuclear decommissioning and 99Tc assessment. The conventional method results more selective than the rapid one, being able to remove almost 100% of the main radiological interferers with the exception of the 90Y; however, the rapid method obtains higher chemical yields (97% vs. 80%) and slightly lower detection limits (0.025 Bq vs. 0.030 Bq) than the conventional. Both methods are similar with regards to equipment and reagent costs.